Edgar Hernández-Andrade

Dr. Edgar Hernández-Andrade


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2013 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
PDF file
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
SHS. S. Hassan
S. S. Hassan
HAH. Ahn
H. Ahn
Steven J KorzeniewskiSteven J Korzeniewski
Steven J Korzeniewski
LYL. Yeo
L. Yeo
RRR. Romero
R. Romero
Objective: To evaluate cervical stiffness during pregnancy using ultrasound‐derived elastography, a method used to estimate the average tissue displacement (strain) within a defined region of interest when oscillatory compression is applied.Methods: Strain was calculated in two regions of interest, the endocervical canal and the entire cervix, from three anatomical planes of the cervix: mid‐sagittal in the plane used for cervical length measurement and in cross‐sectional planes located at the internal and external cervical os. Associations between strain values, method of ascertainment and patient characteristics were assessed using linear mixed models to account for within‐subject correlation. Inter‐rater agreement in defining the degree of cervical stiffness was evaluated in 120 regions of interest acquired by two operators in 20 patients.Results: A total of 1557 strain estimations were performed in 262 patients at 8–40 weeks of gestation. Adjusting for other sources of variation, (1) cervical tissue strain estimates obtained in the endocervical canal were on average 33% greater than those obtained in the entire cervix; (2) measurements obtained in the cross‐sectional plane of the external cervical os and sagittal plane were 45% and 13% greater than those measured in the cross‐sectional plane of the internal cervical os, respectively; (3) mean strain rates were 14% and 5% greater among parous women with and without a history of preterm delivery compared with those of nulliparous women, respectively, and were on average 13% greater among women with a cervical length of between 25 and 30 mm compared to those with a cervical length of > 30 mm; and (4) cervical tissue strain was more strongly associated with cervical length than with gestational age.Conclusion: Semiquantitative elastography can be employed to evaluate changes in cervical stiffness during pregnancy.

16 March 2012 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
PDF file
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
RRRoberto Romero
Roberto Romero
HAHyunyoung Ahn
Hyunyoung Ahn
YHYoussef Hussein
Youssef Hussein
LYLami Yeo
Lami Yeo
SHSonia S. Hassan
Sonia S. Hassan
Objective: To assess the diagnostic performance of transabdominal sonographic measurement of cervical length in identifying patients with a short cervix. Methods: Cervical length was measured in 220 pregnant women using transabdominal and transvaginal ultrasound (US). Reproducibility and agreement between and within both methods were assessed. The diagnostic accuracy of transabdominal US for identifying cases with a cervical length <25 mm was evaluated. Results: Twenty-one out of 220 cases (9.5%) had a cervical length <25 mm by transvaginal US. Only 43% (n = 9) of patients with a short cervix were correctly identified by transabdominal US. In patients with a cervical length of <25 mm by transvaginal US, transabdominal measurement of the cervix overestimated this parameter by an average of 8 mm (95% LOAs, −26.4 to 10.5 mm). Among women without a short cervix, transabdominal US underestimated cervical length on average (LOA) by 1.1 mm (95% LOAs, −11.0 to 13.2 mm). Transvaginal US was also more reproducible (intraclass correlation coefficient: (ICC) (0.96; 95% CI, 0.94 to 0.97) based on comparisons between 2D images and immediately acquired 3D volume datasets relative to transabdominal US (ICC: 0.71; 95% CI, 0.57 to 0.84). Transvaginal US detected 13 cases with funneling and six cases with sludge whereas only three cases of funneling and one of sludge were detected by transabdominal US. Conclusion: Transabdominal measurement overestimated cervical LOA by 8 mm among women with a short cervix and resulted in the underdiagnosis of 57% of cases.

20 December 2013 in Journal of Perinatal Medicine
Verified
Journal Article
Closed access
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
RRRoberto Romero
Roberto Romero
Steven J KorzeniewskiSteven J Korzeniewski
Steven J Korzeniewski
HAHyunyoung Ahn
Hyunyoung Ahn
AAAlma Aurioles-Garibay
Alma Aurioles-Garibay
SHSonia S. Hassan
Sonia S. Hassan
Objective: To determine if there is an association between cervical strain, evaluated using ultrasound elastography, and spontaneous preterm delivery (sPTD) <37 weeks of gestation. Methods: One hundred and eighty nine (189) women at 16–24 weeks of gestation were evaluated. Ultrasound elastography was used to estimate cervical strain in three anatomical planes: one mid-sagittal in the same plane used for cervical length measurement, and two cross sectional images: one at the level of the internal cervical os, and the other at the level of the external cervical os. In each plane, two regions of interest (endocervix and entire cervix) were examined; a total of six regions of interest were evaluated. Results: The prevalence of sPTD was 11% (21/189). Strain values from each of the six cervical regions correlated weakly with cervical length (from r=–0.24, P25th centile [endocervical: odds ratio (OR) 0.2; 95% confidence interval (CI), 0.03–0.96; entire cervix: OR 0.17; 95% CI, 0.03–0.9]. Additional adjustment for gestational age, race, smoking status, parity, maternal age, pre-pregnancy body mass index, and previous preterm delivery did not appreciably alter the magnitude or statistical significance of these associations. Strain values obtained from the external cervical os and from the sagittal view were not associated with sPTD. Conclusion: Low strain values in the internal cervical os were associated with a significantly lower risk of spontaneous preterm delivery <37 weeks of gestation.

29 May 2018 in Journal of Perinatal Medicine
Verified
Journal Article
Closed access
PDF file
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
EMEli Maymon
Eli Maymon
SLSuchaya Luewan
Suchaya Luewan
GBGaurav Bhatti
Gaurav Bhatti
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
RRRoberto Romero
Roberto Romero
Objective: To determine whether a soft cervix identified by shear-wave elastography between 18 and 24 weeks of gestation is associated with increased frequency of spontaneous preterm delivery (sPTD). Materials and methods: This prospective cohort study included 628 consecutive women with a singleton pregnancy. Cervical length (mm) and softness [shear-wave speed: (SWS) meters per second (m/s)] of the internal cervical os were measured at 18–24 weeks of gestation. Frequency of sPTD <37 (sPTD<37) and <34 (sPTD<34) weeks of gestation was compared among women with and without a short (≤25 mm) and/or a soft cervix (SWS <25th percentile). Results: There were 31/628 (4.9%) sPTD<37 and 12/628 (1.9%) sPTD<34 deliveries. The combination of a soft and a short cervix increased the risk of sPTD<37 by 18-fold [relative risk (RR) 18.0 (95% confidence interval [CI], 7.7–43.9); P<0.0001] and the risk of sPTD<34 by 120-fold [RR 120.0 (95% CI 12.3–1009.9); P<0.0001] compared to women with normal cervical length. A soft-only cervix increased the risk of sPTD<37 by 4.5-fold [RR 4.5 (95% CI 2.1–9.8); P=0.0002] and of sPTD<34 by 21-fold [RR 21.0 (95% CI 2.6–169.3); P=0.0003] compared to a non-soft cervix. Conclusions: A soft cervix at 18–24 weeks of gestation increases the risk of sPTD <37 and <34 weeks of gestation independently of cervical length.

21 February 2014 in Journal of Perinatal Medicine
Verified
Journal Article
Closed access
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
AAAlma Aurioles-Garibay
Alma Aurioles-Garibay
MGMaynor Garcia
Maynor Garcia
Steven J KorzeniewskiSteven J Korzeniewski
Steven J Korzeniewski
ASAlyse G. Schwartz
Alyse G. Schwartz
RRRoberto Romero
Roberto Romero
Aim: To investigate the effect of depth on cervical shear-wave elastography. Methods: Shear-wave elastography was applied to estimate the velocity of propagation of the acoustic force impulse (shear wave) in the cervix of 154 pregnant women at 11–36 weeks of gestation. Shear-wave speed (SWS) was evaluated in cross-sectional views of the internal and external cervical os in five regions of interest: anterior, posterior, lateral right, lateral left, and endocervix. Distance from the center of the ultrasound (US) transducer to the center of each region of interest was registered. Results: In all regions, SWS decreased significantly with gestational age (P=0.006). In the internal os, SWS was similar among the anterior, posterior, and lateral regions and lower in the endocervix. In the external os, the endocervix and anterior regions showed similar SWS values, lower than those from the posterior and lateral regions. In the endocervix, these differences remained significant after adjustment for depth, gestational age, and cervical length. SWS estimations in all regions of the internal os were higher than those of the external os, suggesting denser tissue. Conclusion: Depth from the US probe to different regions in the cervix did not significantly affect the SWS estimations.

28 April 2015 in Fetal Diagnosis and Therapy
Verified
Journal Article
Open access
PDF file
AMAditi Mahajan
Aditi Mahajan
AHAmanda Henry
Amanda Henry
NMNeama Meriki
Neama Meriki
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
FCFatima Crispi
Fatima Crispi
AWAlec W. Welsh
Alec W. Welsh
Functional cardiovascular assessment is becoming an increasingly important tool in the study of fetal pathology. The myocardial performance index (MPI) is a parameter measuring global myocardial function. Since its introduction, several studies have proposed methods to improve its reproducibility and have constructed normative reference ranges. Fetal heart evaluation using the MPI is technically challenging, requiring specific training and expertise, and a consensus has yet to be reached on the method of delineating the time periods used to calculate the index. Despite these limitations, it has been shown to be a useful and highly sensitive parameter of dysfunction in a number of fetal pathologies. Further research is warranted into the effect of pathology on MPI, parameters of unilateral cardiac strain that utilise MPI, and automation of the MPI to encourage incorporation of the MPI as a useful tool in clinical practice.