Mohammad Mehrmohammadi

Dr. Mohammad Mehrmohammadi

Assistant Professor, Wayne State University Barbara Ann Karmanos Cancer Institute, Detroit, MI 48201, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Current Molecular Imaging
Verified
Journal Article
Closed access
PDF file
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
SYSoon Joon Yoon
Soon Joon Yoon
DYDouglas Yeager
Douglas Yeager
SEStanislav Emelianov
Stanislav Emelianov
Cancer is one of the leading causes of death in the world. Diagnosing a cancer at its early stages of development can decrease the mortality rate significantly and reduce healthcare costs. Over the past two decades, photoacoustic imaging has seen steady growth and has demonstrated notable capabilities to detect cancerous cells and stage cancer. Furthermore, photoacoustic imaging combined with ultrasound imaging and augmented with molecular targeted contrast agents is capable of imaging cancer at the cellular and molecular level, thus opening diverse opportunities to improve diagnosis of tumors, detect circulating tumor cells and identify metastatic lymph nodes. In this paper we introduce the principles of photoacoustic imaging, and review recent developments in photoacoustic imagingas an emerging imaging modality for cancer diagnosis and staging.

12 October 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
VKViksit Kumar
Viksit Kumar
MDMax Denis
Max Denis
AGAdriana Gregory
Adriana Gregory
Mahdi BayatMahdi Bayat
Mahdi Bayat
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
AAAzra Alizad
Azra Alizad
Shear wave elastography is emerging as a clinically valuable diagnostic tool to differentiate between benign and malignant breast masses. Elastography techniques assume that soft tissue can be modelled as a purely elastic medium. However, this assumption is often violated as soft tissue exhibits viscoelastic properties. In order to explore the role of viscoelastic parameters in suspicious breast masses, a study was conducted on a group of patients using shear wave dispersion ultrasound vibrometry in the frequency range of 50–400 Hz. A total of 43 female patients with suspicious breast masses were recruited before their scheduled biopsy. Of those, 15 patients did not meet the data selection criteria. Voigt model based shear elasticity showed a significantly (p = 7.88x10-6) higher median value for the 13 malignant masses (16.76±13.10 kPa) compared to 15 benign masses (1.40±1.12 kPa). Voigt model based shear viscosity was significantly different (p = 4.13x10-5) between malignant (8.22±3.36 Pa-s) and benign masses (2.83±1.47 Pa-s). Moreover, the estimated time constant from the Voigt model, which is dependent on both shear elasticity and viscosity, differed significantly (p = 6.13x10-5) between malignant (0.68±0.33 ms) and benign masses (3.05±1.95 ms). Results suggest that besides elasticity, viscosity based parameters like shear viscosity and time constant can also be used to differentiate between malignant and benign breast masses.

1 July 2018 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
KGKaustubh A. Gawde
Kaustubh A. Gawde
SSSamaresh Sau
Samaresh Sau
KTKatyayani Tatiparti
Katyayani Tatiparti
SKSushil K. Kashaw
Sushil K. Kashaw
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
Arun K. IyerArun K. Iyer
Arun K. Iyer

14 February 2018 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
YYYan Yan
Yan Yan
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
BMBahador Makkiabadi
Bahador Makkiabadi
Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound imaging and the contrast of optical imaging. For linear-array PAI, a beamformer can be used as the reconstruction algorithm. Delay-and-sum (DAS) is the most prevalent beamforming algorithm in PAI. However, using DAS beamformer leads to low-resolution images as well as high sidelobes due to nondesired contribution of off-axis signals. Coherence factor (CF) is a weighting method in which each pixel of the reconstructed image is weighted, based on the spatial spectrum of the aperture, to mainly improve the contrast. We demonstrate that the numerator of the formula of CF contains a DAS algebra and propose the use of a delay-multiply-and-sum beamformer instead of the available DAS on the numerator. The proposed weighting technique, modified CF (MCF), has been evaluated numerically and experimentally compared to CF. It was shown that MCF leads to lower sidelobes and better detectable targets. The quantitative results of the experiment (using wire targets) show that MCF leads to for about 45% and 40% improvement, in comparison with CF, in the terms of signal-to-noise ratio and full-width-half-maximum, respectively.

22 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KKKarl Kratkiewicz
Karl Kratkiewicz
APAlexander Pattyn
Alexander Pattyn
NANaser Alijabbari
Naser Alijabbari
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
Presently, breast cancer diagnostic methods are dominated by mammography. Although drawbacks of mammography are present including ionizing radiation and patient discomfort, not many alternatives are available. Ultrasound (US) is another method used in the diagnosis of breast cancer, commonly performed on women with dense breasts or in differentiating cysts from solid tumors. Handheld ultrasound (HHUS) and automated breast ultrasound (ABUS) are presently used to generate reflection images which do not contain quantitative information about the tissue. This limitation leads to a subjective interpretation from the sonographer. To rectify the subjective nature of ultrasound, ultrasound tomography (UST) systems have been developed to acquire both reflection and transmission UST (TUST) images. This allows for quantitative assessment of tissue sound speed (SS) and acoustic attenuation which can be used to evaluate the stiffness of the lesions. Another imaging modality being used to detect breast cancer is photoacoustic tomography (PAT). Utilizing much of the same hardware as ultrasound tomography, PAT receives acoustic waves generated from tissue chromophores that are optically excited by a high energy pulsed laser. This allows the user to ideally produce chromophore concentration maps or extract other tissue parameters through spectroscopic PAT. Here, several systems in the area of TUST and PAT are discussed along with their advantages and disadvantages in breast cancer diagnosis. This overview of available systems can provide a landscape of possible intersections and future refinements in cancer diagnosis.

29 May 2018 in Journal of Perinatal Medicine
Verified
Journal Article
Closed access
PDF file
EHEdgar Hernández-Andrade
Edgar Hernández-Andrade
EMEli Maymon
Eli Maymon
SLSuchaya Luewan
Suchaya Luewan
GBGaurav Bhatti
Gaurav Bhatti
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
RRRoberto Romero
Roberto Romero
Objective: To determine whether a soft cervix identified by shear-wave elastography between 18 and 24 weeks of gestation is associated with increased frequency of spontaneous preterm delivery (sPTD). Materials and methods: This prospective cohort study included 628 consecutive women with a singleton pregnancy. Cervical length (mm) and softness [shear-wave speed: (SWS) meters per second (m/s)] of the internal cervical os were measured at 18–24 weeks of gestation. Frequency of sPTD <37 (sPTD<37) and <34 (sPTD<34) weeks of gestation was compared among women with and without a short (≤25 mm) and/or a soft cervix (SWS <25th percentile). Results: There were 31/628 (4.9%) sPTD<37 and 12/628 (1.9%) sPTD<34 deliveries. The combination of a soft and a short cervix increased the risk of sPTD<37 by 18-fold [relative risk (RR) 18.0 (95% confidence interval [CI], 7.7–43.9); P<0.0001] and the risk of sPTD<34 by 120-fold [RR 120.0 (95% CI 12.3–1009.9); P<0.0001] compared to women with normal cervical length. A soft-only cervix increased the risk of sPTD<37 by 4.5-fold [RR 4.5 (95% CI 2.1–9.8); P=0.0002] and of sPTD<34 by 21-fold [RR 21.0 (95% CI 2.6–169.3); P=0.0003] compared to a non-soft cervix. Conclusions: A soft cervix at 18–24 weeks of gestation increases the risk of sPTD <37 and <34 weeks of gestation independently of cervical length.