This in vitro study investigated the fracture resistance of three ceramic-reinforced polymer (CRP) crowns—Cerasmart® 270 (CE; milled), VarseoSmile Crown Plus® (VS; 3D-printed) and the newly developed Hassawat-01 (HS; 3D-printed)—luted with cements of different elastic moduli. The principal hypothesis was that neither the CRP type nor the modulus of cement would significantly affect fracture resistance. Ninety-nine mandibular first molar resin dies were restored with 1 mm thick CE, VS, or HS crowns (n = 33 each) and luted with Maxcem Elite®, RelyX Unicem®, or Ketac Cem® (n = 11 per subgroup). Occlusal cement morphology was evaluated using Micro-CT. Fracture resistance was measured using a universal testing machine. Crowns luted with Maxcem or RelyX withstood forces >2000 N without visible failure. Ketac-luted crowns showed reduced fracture resistance. CE-Ketac fractured in 4 of 11 specimens. VS-Ketac exhibited cracks or complete fractures (1795.2 ± 156.7 N), whereas HS-Ketac showed only superficial cracking (1732.6 ± 127.3 N). CRP crowns luted with lower-modulus resin cements demonstrated superior fracture resistance compared with those luted with glass-ionomer. VS exhibited both cracking and occasional complete fractures, whereas HS exhibited only surface cracking. All materials withstood loads greater than typical masticatory forces, supporting HS as a promising alternative within the CRP.

23 February 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
UPUsanee Puengpaiboon
Usanee Puengpaiboon
PDPavinee Padipatvuthikul Didron
Pavinee Padipatvuthikul Didron
Objectives This study aimed to evaluate fatigue resistance of cast-on implant abutment using three alloys. Materials and Methods Forty specimens of implant-supported crowns were prepared; Group 1 (TA) stock titanium abutments, Group 2 (GS) abutment cast with 40% gold alloy, Group 3 (GP) abutment cast with palladium alloy, and Group 4 (CN) abutment cast with nickel–chromium alloy. Specimens were cyclic loaded at 20 Hz, starting from 200 N (5,000 cycles), followed by stepwise loading of 400, 600, 800, 1,000, 1,200, 1,400, 1,600, and 1,800 N (30,000 cycles/step). Specimens were loaded until failure or reached 245,000 cycles. Statistical Analysis The withstand cycles were analyzed using one-way analysis of variance and Weibull survival analysis. Fracture surfaces were examined using scanning electron microscopy. Results The results of withstand cycles were TA (189,883 ± 22,734), GS (195,028 ± 22,371), GP (187,662 ± 22,555), and CN (200,350 ± 30,851). The statistical analysis showed no significant difference between the groups (p = 0.673). Conclusion Although CN has higher Weibull characteristic strength which means greater durability, its lower Weibull modulus demonstrated less structural reliability. Consistent failures at implant fixture level were also found in CN group. Article published online: 23 February 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

13 July 2026 in Polymers
Verified
Journal Article
Open access
PDF file
NSNaluemol Sriprasert
Naluemol Sriprasert
Nantawan KrajangtaNantawan Krajangta
Nantawan Krajangta
TWThanakorn Wasanapiarnpong
Thanakorn Wasanapiarnpong
PDPavinee Padipatvuthikul Didron
Pavinee Padipatvuthikul Didron
TRThanasak Rakmanee
Thanasak Rakmanee
A novel alumina-filled ceramic-reinforced polymer (CRP) crown (Hassawat-01; HS) was developed. This study evaluated the effect of luting cement on the marginal and internal adaptation of HS and compared its performance with a commercial DLP-printed CRP (VarseoSmile Crown Plus®; VS) and a milled resin nanoceramic (Cerasmart® 270; CE). Ninety-nine crowns (n = 33/material) were fabricated with a 50 µm cement space and luted using Maxcem Elite®, RelyX Unicem®, or Ketac Cem® (n = 11/subgroup). Adaptation was assessed without and with cementation using micro-computed tomography at 160 measurement points per crown. Without cementation, HS demonstrated the most favorable internal adaptation, whereas VS showed the best marginal adaptation. Following cementation, gap dimensions increased in all groups. Despite its superior non-cementation fit, HS exhibited the greatest increase in marginal and internal discrepancies, suggesting increased hydraulic resistance during seating. Among the evaluated cement–crown combinations, VS luted with RelyX Unicem® showed the most favorable post-cementation adaptation. Post-cementation analysis was limited to HS and VS because the radiopacity of CE prevented reliable cement interface segmentation. These findings indicate that adaptation is influenced by both crown geometry and cement properties, and that highly adapted intaglio surfaces may require careful cement selection to optimize clinical fit.