Carbon sequestration in deep saline aquifers was recently developed at the industrial scale. CO2 injection experiences in carbonates are quite limited, most of them coming from projects carried out in porous mediums in the USA and Canada. Hontomín (Spain) is the actual on-shore injection pilot in Europe, being a naturally fractured carbonate reservoir where innovative CO2 injection strategies are being performed within the ENOS Project. CO2 migration through the fracture network existing on site produces hydrodynamic, mechanical and geochemical effectsdifferent from those caused by the injection in mediums with a high matrix permeability. The interpretation of these effects is required to design safe and efficient injection strategies in these formations. For this, it is necessary to determine the evolution of pressure, temperature and flow rate during the injection, as well as the period of pressure recovery during the fall-off phase. The first results from the not-continuous injections (8–24 h) conducted at Hontomín reveal the injection of liquid CO2 (density value of 0.828 t/m3) and the fluid transmissivity through the fractures. Taking into account the evolution of the pressure and flow rate showed variations of up to 23% and 30% respectively, which means that the relevant changes of injectivity took place. The results were modeled with a compositional dual media model which accounts for both temperature effects and multiphase flow hysteresis because alternative brine and CO2 injections were conducted. Advanced modeling shows the lateral extension of CO2 and the temperature disturbance away from the well.
CO2 geological storage in deep saline aquifers was recently developed at industrial scale mainly in sandstone formations. Experiences on CO2 injections in carbonates aquifers for permanent trapping are quite limited, mostly from US projects such as AEP Mountaineer, Michigan and Williston Basin. The behavior of fractures in carbonates plays a key role in those reservoirs in which porous matrix permeability is very poor, which drives the CO2 plume migration through the fracture network where hydromechanics and geochemical effects take place due to injection. Hontomín (Spain) is the actual on-shore injection pilot in Europe (EP Resolution of 14 January 2014), whose reservoir is comprised of fractured carbonates. Existing experiences from field scale tests conducted on site have supported to better understand the behavior of this type of reservoirs for CO2 geological storage. Innovative CO2 injection strategies are being carried out in ENOS Project (EU H2020 Programme, http://www.enos-project.eu). First results based on field tests conducted at Hontomín, and the advanced modelling developed so far will be analyzed and discussed in this article, as well as, the description of future works. The evolution of operating parameters such as flow rate, pressure and recovery term during the tests confirm the CO2 migration through the fractures.
The detonation of explosives in the open air was studied, analyzing different amounts of explosives detonated at different distances, monitoring the overpressure or air blast wave generated with the aim of determining a model, which allows to establish safety zones. A series of tests measuring the air wave with different loads and sensors placed at various distances from the origin of the explosion were carried out. The work was focused on designing full-scale trials that allowed to develop a predictive empirical method based on the calculation model of the equivalent mass of TNT. A total of 18 different gelatinous dynamite charges, placing the sensor at six different distances from the origin of the explosion, produced a total of 90 tests measuring the air wave produced by the detonation of gelatinous dynamite. Later, the outdoor detonation of 10 TNT explosive charges was analyzed to extend the model and improve its scope. With all this, it has been possible to develop a predictive model that allows assessing the overpressure generated by the detonation of a TNT-equivalent explosive charge. The results are useful to predict the air blast wave in common open-air blasts, such as those carried out with shaped charges to demolish metallic structures. On the other hand, the results are also useful to determine the air blast wave overpressure in the case of large explosive charges detonated in the open air, such as accidental explosive detonation or terrorist bombs. It is important to point out the relevance of the results achieved after the detonation of large explosive charges (more than 80 kg) simulating a type of bomb frequently used by terrorists. Reproducing the explosion on a real scale, the results are fully representative of the overpressure produced by an explosion of these characteristics without the need of extrapolating the results of tests with small loads. In addition, the detonation was carried out with TNT, which can serve as a standard to compare with any other type of explosive.
Cyclic carbon dioxide energy storage requires repeated subsurface injection and production to deliver electricity. Its assessment therefore depends on the relationship between operating requirements, available operating data and documents, and the legal conditions governing the activity. This study examines that relationship through computational analysis and a review of European storage regulation. Thermodynamic and mass-balance calculations are combined with operating-time comparisons, adjustment of infrastructure data and assessment of pilot data. The findings show that conclusions depend on consistent operating-requirement definitions and on distinctions between observed performance, calculated requirements and assumed operating conditions. Storage studies report relevant site measurements and operating conditions, but they do not demonstrate the performance of a cyclic electricity-storage system. National storage rules also differ by territory and activity, and approval for permanent storage cannot be presumed to permit cyclic use. Environmental protection, availability of required resources, funding and authority for operating and post-closure actions require separate assessment. The results identifies the measurements and documents needed to evaluate a proposed operating requirement and the technical and legal questions that remain unresolved. It provides a basis for examining site-specific proposals without inferring feasibility or climate benefit from storage capacity or circulated carbon dioxide alone.