Haiwu Zheng

Haiwu Zheng


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2025 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
HXHao Xiong
Hao Xiong
HZHaiwu Zheng
Haiwu Zheng
DZDingxuan Zhao
Dingxuan Zhao
YFYan Feng
Yan Feng

17 December 2025 in Actuators
Verified
Journal Article
Open access
PDF file
HZHaiwu Zheng
Haiwu Zheng
HXHao Xiong
Hao Xiong
DZDingxuan Zhao
Dingxuan Zhao
YRYinying Ren
Yinying Ren
SCShuoshuo Cao
Shuoshuo Cao
LLLiangpeng Li
Liangpeng Li
System time delays and nonlinear unmodeled dynamics severely constrain the control performance of the Active Suspension Electro-Hydraulic Servo Actuator (ASEHSA). To tackle these challenges, this paper presents a Dynamic Error Differentiation-based Model-Free Adaptive Control (DE-MFAC) strategy integrated with an Improved Particle Swarm Optimization (IPSO) algorithm. Established under the Model-Free Adaptive Control (MFAC) framework, the DE-MFAC integrates a dynamic error differentiation mechanism and an implicit expression of time delays, thus removing the dependence on a precise system model. The traditional PSO algorithm is improved by incorporating an inertia weight adjustment strategy and a boundary reflection wall strategy, which effectively mitigates the issues of local optima and boundary stagnation. In AMESim 2021, a 1/4 vehicle active suspension electro-hydraulic actuation system model is constructed. To ensure an impartial evaluation of controller performance, the IPSO algorithm is employed to optimize the parameters of the PID, MFAC, and DE-MFAC controllers, respectively. Co-simulations with Simulink 2023b are conducted under two time delay scenarios using a composite square-sine wave signal as the reference. The results indicate that all three IPSO-optimized controllers realize effective position tracking. Among them, the DE-MFAC controller exhibits the optimal performance, demonstrating remarkable advantages in reducing tracking errors and balancing settling time with overshoot. These findings verify the effectiveness of the proposed control strategy, time delay compensation mechanism, and optimization algorithm. Future research will involve validation on a physical ASEHSA platform, further exploration of the method’s applicability and robustness under diverse operating conditions, and extension to other industrial systems with similar nonlinear time delay features.

4 March 2026 in Actuators
Verified
Journal Article
Open access
PDF file
HZHaiwu Zheng
Haiwu Zheng
HXHao Xiong
Hao Xiong
DZDingxuan Zhao
Dingxuan Zhao
YZYufei Zhao
Yufei Zhao
YRYinying Ren
Yinying Ren
YHYi Han
Yi Han
To address performance degradation and control instability in electro-hydraulic servo active suspension systems due to internal leakage faults arising from wear and aging of hydraulic components, this paper proposes an innovative fuzzy PID fault-tolerant controller based on the Improved Giant Armadillo Optimization (IGAO) algorithm. Specifically, to overcome the limitations of the standard Giant Armadillo Optimization (GAO), which is prone to local optima and exhibits poor convergence performance when handling multi-constraint parameter optimization problems, this study introduces a nonlinear dynamic inertia weight mechanism and a random reflection strategy for out-of-bounds particles to improve the original algorithm’s performance. These enhancements significantly enhance its ability to balance global exploration and local exploitation. Furthermore, this research develops a comprehensive performance evaluation fitness function by quantifying key performance indicators such as body acceleration, suspension dynamic deflection, and tire dynamic load. A quarter-car model incorporating an internal leakage fault was established as a simulation validation platform to demonstrate the reliability of the proposed method. Simulation results indicate that under various road excitation conditions, the proposed IGAO algorithm can rapidly and stably converge to superior parameters for the fuzzy PID controller. Compared to the Particle Swarm Optimization (PSO) and standard GAO algorithm, the control system optimized by IGAO not only significantly more effectively suppresses body vibration and reduces shock amplitude but also exhibits stronger dynamic recovery performance and control robustness under varying degrees of internal leakage faults. This research provides a robust control approach for addressing internal parameter uncertainties in hydraulic systems and offers a new approach to theoretical modeling for enhancing the reliability of design and fault-tolerant control capabilities of active suspension systems.

21 February 2026 in Actuators
Verified
Journal Article
Open access
PDF file
HXHao Xiong
Hao Xiong
DZDingxuan Zhao
Dingxuan Zhao
HZHaiwu Zheng
Haiwu Zheng
LZLiqiang Zhao
Liqiang Zhao
The Electro-Hydraulic Servo Actuator for Active Suspensions (ASEHSA) plays a decisive role in shaping the holistic performance of vehicle suspension systems through its dynamic response speed and control precision. However, achieving high-performance control of ASEHSA still faces challenges. On one hand, existing model-based control methods are highly sensitive to parameter uncertainties and unmodeled nonlinear hydraulic dynamics, which can easily lead to reduced robustness in practical applications. On the other hand, traditional model-free strategies have limited time-delay compensation capabilities and often struggle to balance overshoot and settling time under delayed and disturbed conditions. To resolve this challenge, this study proposes an improved model-free adaptive control method that incorporates the differentiation of the tracking error (DE-IMFAC). Within the framework of traditional model-free adaptive control (MFAC), this approach reconfigures the time-delay term from an explicit form in the control law to implicit management, substantially mitigating the influence of time delays on system control performance. At the same time, by refining the performance criterion function and integrating a tracking error differentiation term together with dynamic weighting factors, the dynamic performance and adjustment flexibility of the controller are significantly enhanced. Additionally, by leveraging the characteristic equation of discrete autonomous systems and compression mapping theory, the BIBO stability of the DE-IMFAC control system and the monotonic convergence of the tracking error are rigorously established through theoretical analysis. Simulation and experimental results demonstrate that, compared with PID and traditional MFAC methods, DE-IMFAC significantly reduces integral absolute error, overshoot, settling time, and maximum position tracking error, while improving disturbance rejection capability. This approach does not depend on an accurate mathematical model of the ASEHSA system and maintains robust dynamic performance under complex operating environments characterized by time delays and data disturbances, providing a practical solution for ASEHSA and related industrial control systems.

30 January 2026 in Actuators
Verified
Journal Article
Open access
PDF file
HXHao Xiong
Hao Xiong
DZDingxuan Zhao
Dingxuan Zhao
HZHaiwu Zheng
Haiwu Zheng
XWXuechun Wang
Xuechun Wang
ZHZiqi Huang
Ziqi Huang
LLLiangpeng Li
Liangpeng Li
The dynamic response accuracy of suspension servo actuators directly determines the vibration-reduction performance of active-suspension systems. However, during long-term service, the system is prone to the influence of compound-degradation faults, such as internal leakage and time delay, leading to a significant decline in control performance. To address this issue, this paper proposes a collaborative control framework combining model-free adaptive control with a differential term of tracking error (DE-MFAC) and an improved particle swarm optimization (IPSO) algorithm. Firstly, to overcome the limitations of traditional model-free adaptive control (MFAC), a DE-MFAC strategy is constructed by implicitly handling the time-delay term and introducing the differential term of tracking error and dynamic weight factor into the performance index. Secondly, to enhance the parameter-tuning effect, the traditional particle swarm optimization (PSO) algorithm is improved (IPSO) by incorporating a dynamic inertia weight and an out-of-bounds random reflection mechanism, thereby strengthening the global optimization capability. On this basis, a suspension servo actuator system model incorporating internal leakage and time-delay faults is established based on the co-simulation platform of Simulink and AMESim, and the proposed method is validated. The simulation results show that, compared with the optimized traditional MFAC, the DE-MFAC tuned by IPSO exhibits superior position-tracking accuracy, faster response speed, and stronger overshoot-suppression capability under various compound-fault conditions. Further analysis indicates that the Integral of Absolute Cubic Error (IACE) function, due to its higher sensitivity to large deviations, can more effectively suppress overshoot and is suitable for engineering scenarios with strict requirements on dynamic performance. In addition, the optimization of control parameters using the IPSO algorithm can effectively compensate for the performance degradation caused by degradation faults, providing a feasible technical approach for extending the service life of actuators through adaptive adjustment.

17 November 2026 in Actuators
Verified
Journal Article
Open access
PDF file
SHSong He
Song He
ZDZhikui Dong
Zhikui Dong
ZMZeyang Meng
Zeyang Meng
HAHuijiang An
Huijiang An
KZKaiming Zang
Kaiming Zang
HZHaiwu Zheng
Haiwu Zheng
Pump-controlled hydraulic die cushions offer energy-efficient actuation, but accurate position control is challenged by flow dead-zone nonlinearity, parameter perturbations, and external load disturbances. This study proposes a coordinated dead-zone inverse compensation (DIC) and improved active disturbance rejection control (IADRC) strategy, termed DIC-IADRC. A mechanism-based dead-zone model is derived by considering leakage across multiple piston-pump friction pairs and oil compressibility. A smooth inverse compensator is constructed using experimentally identified parameters, and its compensation error is explicitly introduced into a high-order sliding mode observer (HOSMO) as a known input for finite-time disturbance estimation. The improved ADRC further incorporates a full-range fast tracking differentiator (FFTD) and nonlinear state error feedback (NLSEF) to suppress differentiation chattering and balance response speed and smoothness. The strategy is evaluated on a physical pump-controlled hydraulic die-cushion test bench through step tracking, sudden-load disturbance rejection, and sinusoidal tracking experiments, with PID, standard ADRC, and DIC-ADRC as benchmarks. Compared with PID, DIC-IADRC reduces step overshoot by 79.4%, steady-state mean absolute error (MAE) by 83.6%, peak sudden-load tracking error by 64.9%, and maximum sinusoidal tracking deviation by 35.7%. It also outperforms standard ADRC and DIC-ADRC across the tested operating conditions.