This is a retrospective, single-center cohort study comparing the long-term radiographic osseointegration and aseptic loosening between a 3D-printed EPORE® collar and a prior generation HA-coated collar in endoprosthetic reconstructions. Achieving stable bone integration in endoprosthetic reconstructions remains challenging, with hydroxyapatite (HA)-coated collars being the only option available in the past. Earlier studies from our center have shown reliable and accelerated osseointegration at the bone–collar interface using a novel highly porous 3D-printed EPORE® collar system compared to a previously used HA-coated collar. Methods: Twenty-eight patients who underwent an implantation of endoprostheses utilizing the novel 3D-printed EPORE® collar system were case-matched to 24 patients who had previously undergone surgeries using a HA-coated collar. The mean age at surgery was 65.2 years (range: 17–95 years). Patients in the HA-coated collar group had a mean age of 63.8 years (range: 17–86 years), while those in the 3D-printed collar group had a mean age of 66.7 years (range: 32–95 years), with no statistically significant difference between groups (p = 0.876). A minimum radiological and clinical follow-up of 2 years was available in all included cases. Osseointegration was evaluated using postoperative plain radiographs in two planes based on a previously validated semi-quantitative score. Results: When aseptic loosening was used as the primary endpoint, no failures occurred in the 3D-printed EPORE® group during the study period. The overall rate of stem loosening (including both aseptic and septic causes) was 7% (2/28) in the 3D-printed group and 16% (4/24) in the HA-coated group. All cases of loosening in the 3D-printed cohort were related to septic failure. This translates into a 2-year aseptic-loosening-free survival of 100% in the 3D-printed group. When the radiographic osseointegration was analyzed as the endpoint, the rate of successful osseointegration was significantly higher in the 3D-printed group (92.9%, 26/28; 95% CI 76.5–99.1%) compared with the HA-coated group (70.8%, 17/24; 95% CI 48.9–87.4%; p = 0.04). The distribution of ongrowth scores also differed significantly between groups. The highest ongrowth score (grade 4) was achieved in 82.14% of 3D-printed implants (23/28; 95% CI 63.1–93.9%), compared with 37.5% of HA-coated implants (9/24; p = 0.0002). The time to achieve grade 4 ongrowth was significantly shorter in the 3D-printed cohort, with a median of 470 days (IQR 360–610), compared with 1482 days (IQR 1020–1860) in the HA-coated group (p < 0.0001). In addition, patients in the 3D-printed implant group had a significantly higher mean body mass index compared with the HA-coated group (32.51 vs. 28.36, p = 0.01). Conclusions: These results show that the novel highly porous 3D-printed EPORE® collars reduce aseptic loosening and accelerate extracortical bridging in endoprosthetic replacements. This benefit persisted even in higher BMI or revision contexts when compared to the previously used HA-coated collars.
Aims: Combined endoprosthetic replacement of the ipsilateral distal femur and proximal tibia is rarely performed. It is usually undertaken to achieve limb salvage after resection of primary bone tumours around the knee. This study aims to determine the viability of ‘composite’ endoprosthetic reconstruction around the knee, and report implant survival and limb salvage rates. Methods: A retrospective review of a prospectively maintained departmental database was undertaken to identify patients who had undergone composite endoprosthetic reconstruction around the knee. The primary outcome of interest was revision-free implant survival. Secondary outcomes were amputation-free survival, the Musculoskeletal Tumor Society (MSTS) score, and extensor lag. A total of 34 patients (21 male and 13 female) with a mean age of 32 years (14 to 66) underwent surgery between January 1997 and November 2024, and were followed up for a median interval of 12.6 years (IQR 3 to 14). Results: The oncological diagnoses were osteosarcoma (n = 26), Ewing’s sarcoma (n = 5), and one each of giant cell tumour of bone, spindle cell sarcoma, chondrosarcoma, and synovial sarcoma. Of the eight primary and 26 revision cases, the pooled five- and ten-year revision-free implant survival rates were 77% (95% CI 63 to 94%) and 61% (95% CI 45 to 83), respectively (Kaplan-Meier). Resection length and construct:stem ratio had no impact on revision rate. Limb salvage at five and ten years was 81% (95% CI 68 to 96) and 69% (95% CI 54 to 89), respectively. Range of motion outcomes were available in 30 patients and MSTS scores in 20 patients. The mean extensor lag was 25° (10° to 50°) and the mean MSTS score was 53% (27% to 67%). Conclusion: Composite endoprosthetic reconstruction around the knee after tumour resection is a viable limb salvage option in the primary or revision setting; however, it does carry a risk of reoperation in the medium and long term. The leading reason for failed limb salvage in the long term is infection. We recommend careful patient selection and preoperative discussion before contemplating composite reconstruction. Cite this article: Bone Joint J 2026;108-B(6):827–834.
10 September 2026 in European Journal of Surgical Oncology
Achieving stable bone integration in megaprosthetic reconstructions remains challenging, with traditional hydroxyapatite (HA)-coated collars showing variable outcomes. This study compares long-term osseointegration and clinical performance of a novel 3D-printed porous collar (EPORE®) versus conventional HA-coated collars in 52 patients (28 with 3D-printed, 24 with HA-coated). Radiographic osseointegration was assessed using a validated scoring system, with follow-up exceeding two years. The 3D-printed group demonstrated significantly higher osseointegration rates (92.9% vs. 70.8%, p=0.04) and faster bone ongrowth (470 vs. 1482 days to full integration, p<0.0001), with 89.3% achieving the highest integration score compared to 37.5% in the HA group (p=0.0002). Notably, no aseptic loosening occurred with 3D-printed collars, while HA-coated collars had an 8% aseptic loosening rate. Despite higher BMI in the 3D-printed group (32.5 vs. 28.4, p=0.01), outcomes were superior, suggesting the porous design mitigates obesity-related risks. These findings indicate that 3D-printed collars enhance biological fixation, reduce loosening, and improve implant stability, particularly in complex revisions. This technology represents a significant advancement in megaprosthetic design, with potential to improve long-term outcomes in high-risk patients.