Summary: Cotton seeds are typically covered by lint and fuzz fibres. Natural ‘fuzzless’ mutants are an ideal model system for identifying genes that regulate cell initiation and elongation. Here, using a genome‐wide association study (GWAS), we identified a ~ 6.2 kb insertion, larINDELFZ, located at the end of chromosome 8, composed of a ~ 5.0 kb repetitive sequence and a ~ 1.2 kb fragment translocated from chromosome 12 in fuzzless Gossypium arboreum. The presence of larINDELFZ was associated with a fuzzless seed and reduced trichome phenotypes in G. arboreum. This distant insertion was predicted to be an enhancer, located ~ 18 kb upstream of the dominant‐repressor GaFZ (Ga08G0121). Ectopic overexpression of GaFZ in Arabidopsis thaliana and G. hirsutum suggested that GaFZ negatively modulates fuzz and trichome development. Co‐expression and interaction analyses demonstrated that GaFZ might impact fuzz fibre/trichome development by repressing the expression of genes in the very‐long‐chain fatty acid elongation pathway. Thus, we identified a novel regulator of fibre/trichome development while providing insights into the importance of noncoding sequences in cotton.
1 January 2019 in Vector-Borne and Zoonotic Diseases
This study investigated the abundance of mosquitoes and circulation of mosquito-borne arboviruses from 16 villages in 8 cities of Hunan Province, China, in July–August of 2010 and in August of 2011. In total, 16,076 mosquitoes consisting of seven species from four genera were collected by ultraviolet-light trap. Culex quinquefasciatus was the most common species, accounting for 50.63% (8140/16,076) of the total. Anopheles sinensis (24.26%, 3900/16,076) made up the second most common species, followed by Culex tritaeniorhynchus (9.76%, 1569/16,076). The proportions of Culex pipiens pallens, Armigeres subalbatus, and Culex modestus were 6.7%, 5.2%, and 3.31%, respectively. Fourteen Aedes albopictus were detected. The mosquitoes were identified by morphologic characteristics and frozen in liquid nitrogen. The mosquitoes were pooled, triturated, and centrifuged. The clarified supernatant was used to inoculate monolayers of C6/36 and baby hamster kidney-21 cells. We obtained six virus isolates that caused cytopathic effects. Phylogenetic analysis revealed that two isolates were Akabane virus (AKAV, from A. sinensis and C. quinquefasciatus), two isolates were Japanese encephalitis virus (from C. pipiens pallens and C. quinquefasciatus), and two isolates were Tibet orbivirus (from C. quinquefasciatus and C. tritaeniorhynchus). This is the first report of AKAV isolated from A. sinensis and C. quinquefasciatus in nature in China. The detection of AKAV in these species confirms circulation of AKAV in Hunan province and suggests potential challenges to the prevention and control of arthropod-borne animal viruses in mainland China.
As key devices in dynamic measurement, the precision and accuracy of accelerometers not only directly influence the performance of the equipment they are part of but also can impact user safety. Accelerometers must undergo pre-factory calibration and regular recalibration during usage, attributable to factors like manufacturing and installation errors, as well as environmental conditions. Currently, the majority of initial calibrations for accelerometers depend on laser interferometry measurement technology. However, ensuring the accuracy and stability of laser measurements is difficult, since laser wavelengths are easily affected by environmental factors, and on-site traceability calibration presents challenges. In this paper, we utilize a chromium atom self-traceable grating, whose pitch is traceable to natural constants (grating pitch d=212.78nm), and combine it with a laser self-mixing grating interferometer and vibrator calibration technology, introducing a novel method for accelerometer calibration. The system’s efficacy was validated using a commercial accelerometer as a test subject. This calibration technique not only promises to enhance the accuracy and interference resistance of the vibrator calibration method but also addresses the issue of on-site traceability.
The characterization of scanning tip morphology is crucial for accurate linewidth measurements. Conventional rectangular characterizers are affected by lateral distortion caused by the nonlinearities in AFM scanning, leading to errors between the actual characterization results and the true values. In this study, we innovatively developed self-traceable two-dimensional nano-gratings using chromium atomic deposition technology and extreme ultraviolet interference lithography. We used this structure as a characterizer for conducting scanning tip characterizations.This paper analyzed the periodic stability of the grating sample during scanning and corrected the lateral distortion of atomic force microscopy (AFM) at scan scales of 0.5 µm and 1 µm based on its self-traceable characteristics. Additionally, we extracted the angle information of the scanning tip in the X direction and Y direction within a scan scale of 0.5 µm. The results demonstrate that the two-dimensional grating sample exhibited excellent periodic stability during scanning. The characterization errors for the tip’s X direction and Y direction angles are within ±2°, showing high consistency. This study highlights that self-traceable two-dimensional grating samples have the capability for in situ bidirectional characterization of tip information, providing a creative solution for the development of new-style tip characterizers.
31 March 2025 in IEEE Transactions on Instrumentation and Measurement
As a key component in motion state sensing, the accuracy of accelerometers directly affect the performance and safety of their systems. However, their sensitivity can influenced due to various factors during operation, necessitating both pre-deployment and periodic calibration. Traditional primary calibration methods rely on laser interferometers, yet their trueness and stability are compromised by environmental disturbances affecting the laser wavelength, making on-site traceability challenging. Addressing these issues, this study combines a Cr self-traceable grating with a homodyne littrow grating interferometer and primary vibration calibration technique. Leveraging the high line density, stability, and traceability of the self-traceable grating, it achieves high accuracy and on-site traceable calibration. In experiments, the effectiveness of this calibration system was validated using commercial accelerometers, achieving a measurement uncertainty of 0.25%. This calibration technique not only enhances the accuracy and environmental adaptability of accelerometer calibration but also addresses the critical issue of on-site traceability, representing the future direction of in-field accelerometer calibration.
The linearity of the accelerometer directly affects its measurement accuracy and applicability, making it a key metric in the development of high-performance accelerometers. In response, this paper proposes an ultra-high linearity MOEMS accelerometer based on a self-traceable grating (STG) interferometer. The accelerometer integrates a MEMS resonator with a STG interferometer based on chromium (Cr) atom transition frequency 7S3 → 7P4, enabling direct traceability of displacement to the International System of Units (SI) “meter”. Specifically, the average pitch of the Cr grating used is (212.781±0.008) nm (k = 2), showing outstanding uniformity and long-term stability. Furthermore, the compact interferometer design gives it an overall size of just 7.5 cm × 7.5 cm × 2 cm, facilitating portable measurements in practical applications. Experimental results show that the accelerometer achieves ultra-high performance with a nonlinearity of 0.04%. The device also demonstrates a sensitivity of 13.77 μm/g within a measurement range of ±1.6 g, with a noise floor of 9.6×10-7 g/√Hz. The integration of STG technology with the MEMS resonator offers a scalable solution for high-precision, field-deployable accelerometer measurements, greatly improving measurement linearity and traceability.