Aeration is one of the most energy-intensive operations in wastewater treatment plants, with its efficiency strongly affected by the presence of surfactants. This study investigates the impact of Sodium Dodecyl Sulphate (SDS) on oxygen mass transfer using a commercial fine-bubble diffuser. Oxygen transfer experiments were performed under varying air flow rates and SDS concentrations. Key parameters, including the volumetric mass transfer coefficient (), gas holdup, bubble size, and interfacial area, were experimentally measured and analysed. SDS reduces the average bubble diameter by up to 50%; above 4 mg/L, further increases in concentration do not change the bubble size. Gas holdup increases by approximately 2% per mg L−1 of SDS, and a new empirical correlation was proposed to predict gas holdup as a function of air flow rate and surfactant concentration, achieving an R2 of 0.97 with deviations below 10%. Despite the increase in interfacial area, SDS strongly suppresses interfacial turbulence, reducing the liquid-side mass transfer coefficient () by up to 70%, which ultimately leads to a significant loss of overall oxygen transfer efficiency. The Sardeing model, originally developed for single bubbles, successfully predicted within ±15% of the experimental values, demonstrating its potential as a practical tool for estimating oxygen transfer in aeration systems. These findings highlight the substantial impact of surfactants on fine-bubble aeration performance and underscore the need to account for their effects in the design and operation of industrial aeration systems.
Fine-bubble aeration is a core process in wastewater treatment plants (WWTPs). However, the physical mechanisms linking bubble plume hydrodynamics to oxygen transfer performance remain insufficiently quantified under configurations representative of full-scale installations. This study presents a local multi-sensor experimental characterization of a multiple bubble plume system using a 4 × 4 array of commercial membrane diffusers in a pilot-scale aeration tank (2 m3), emulating WWTP diffuser density and geometry. Airflow rate was varied to analyze its effects on mixing and oxygen transfer efficiency. The experimental methodology combines three complementary measurement approaches. Oxygen transfer performance is quantified using a dissolved oxygen probe. Liquid-phase velocity fields are then mapped using Acoustic Doppler Velocimetry (ADV). Finally, local two-phase measurements are obtained using dual-tip Conductivity Probe (CP) arrays, which provide bubble size, bubble velocity, void fraction, and Interfacial Area Concentration (IAC). Based on these observations, a zonal hydrodynamic model is proposed to describe plume interaction, wall-driven recirculation, and the formation of a collective plume core at higher airflows. Quantitatively, the results reveal a 29% reduction in Standard Oxygen Transfer Efficiency (SOTE) between 10 and 40 m3/h, driven by a 41% increase in bubble size and an 18% rise in bubble velocity. Bubble chord length also increased with height, by 33%, 19%, and 15% over 0.8 m for 10, 20, and 40 m3/h, respectively. These trends indicate that increasing airflow enhances turbulent mixing but simultaneously enlarges bubbles and accelerates their ascent, thereby reducing residence time and negatively affecting oxygen transfer. Overall, the validated multiphase datasets and mechanistic insights demonstrate the dominant role of diffuser interaction in dense layouts, supporting improved parameterization and experimental benchmarking of fine-bubble aeration systems in WWTPs.
4 March 2026 in Nuclear Engineering and Technology
Aeration is one of the most energy-intensive operations in wastewater treatment plants, with its efficiency strongly affected by the presence of surfactants. This study investigates the impact of surfactants on oxygen mass transfer using a commercial fine bubble diffuser. Oxygen transfer experiments were performed under varying air flow rates and surfactant concentrations. Key parameters, including the volumetric mass transfer coefficient (kLa), gas holdup, bubble size, and interfacial area, were experimentally measured and analysed. Results show that kLa increases with air flow rate due to larger interfacial area, while the Standard Oxygen Transfer Efficiency (SOTE) decreases, particularly at higher surfactant concentrations. Surfactants promote smaller bubble sizes and higher gas holdup, thus increasing the interfacial area. However, they significantly reduce the liquid-side mass transfer coefficient (kL) by suppressing interfacial turbulence. Despite the increased interfacial area, the reduction in kL leads to lower overall oxygen transfer efficiency. These findings highlight the importance of accounting for surfactant effects in the design and operation of industrial aeration systems.