Representative Publications

View All Publications
28 July 2025 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
VMVictoria P. Marino
Victoria P. Marino
FVFrancesca de Vecchi
Francesca de Vecchi
TKTakayuki Koya
Takayuki Koya
LBLandon M Begin
Landon M Begin
DMDouglas C. Moore
Douglas C. Moore
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer
Hemiarthroplasty is used to treat joint damage confined to one side, aiming to preserve the remaining healthy cartilage and bone while addressing conditions like femur fractures and osteonecrosis; however, challenges persist due to cartilage wear and inconsistent clinical outcomes. This scoping review evaluates in vitro studies on hemiarthroplasty bearing materials (HBM), focusing on the HBM tested, cartilage specimens, experimental setups, outcome variables, and the comparability of results. Of 1798 identified studies, 72 met the inclusion criteria, with 48 classified as in vitro. HBMs tested included metals (42%) and soft polymers (30%) and 45% of studies utilized multiple distinct HBMs. Cartilage specimens were predominantly bovine (65%), mostly from the tibial‐femoral joint (69%). The two most common experimental set ups were tribometers (75%) and simulators (25%) both using commercial and custom‐built rigs. Tribometer configurations included pin‐on‐disc and pin‐on‐plate models and simulators highlighted ball‐on‐joint set ups. Tribometer motions included linear reciprocating (62%) or multidirectional reciprocating (24%). Input parameters included contact stress (8.8 kPa to 23.3 MPa, mean 2.1 MPa), velocity (0.5‐100 mm/s, mean 16.46 mm/s), testing duration (0.03–33.8 h, mean 5.4 h), and distance (5.4 cm to 9000 m, mean 393 m). Simulators used inputs of loads ranging from 25 N to 1.5 kN, 500 to 500,000 cycles and a variety of flexion‐extension profiles together with secondary motions. Lubricants were mostly bovine calf serum (38%) and saline‐based solutions (21%). Outcome variables mainly included coefficient of friction and damage to cartilage and/or HBM, but the methods to assess these outputs varied. Methodological differences and inconsistent reporting of outcomes limited the ability to draw firm conclusions about the relative performance of HBMs.

24 August 2025 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
LBLandon M Begin
Landon M Begin
VMVictoria P. Marino
Victoria P. Marino
FVFrancesca de Vecchi
Francesca de Vecchi
DMDouglas C. Moore
Douglas C. Moore
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer
JCJoseph J. Crisco
Joseph J. Crisco
Hemiarthroplasty is commonly used to treat damage localized to one side of a synovial joint, maximally preserving the patient's opposing healthy bone and cartilage; however, challenges remain due to accelerated wear of the cartilage articulating with the implant surface. This scoping review summarized investigations of hemiarthroplasty bearing materials (HBMs) utilizing animal models. The review focused on HBMs tested, animal models used, duration of animal survival, and outcome assessments (e.g., gait analysis, image analysis, histological staining, and cartilage scoring). The initial search was designed to broadly capture all studies evaluating HBMs articulating against articular cartilage. A total of 1798 studies were identified, which after screening yielded 72 that met the inclusion criteria. Of these, 24 were classified as in vivo and were included in this review. The HBMs evaluated included metals (63%), hard and soft polymers (33%), ceramics (17%), and synthetic carbons (17%). HBMs were predominantly studied in canines (46%), rabbits (25%), and sheep (21%), with survival durations from 2 to 104 weeks. Outcome assessment of cartilage wear varied across studies and histological staining was performed in all studies with the most common stains being Safranin‐O (58%) and Hematoxylin and Eosin (54%). Commonly used cartilage scoring systems were Mankin and Modified Mankin (38%); however, among all studies, scales and sub‐categories for scoring criteria varied drastically. While similarities were identified with respect to HBMs, animal models, and some outcome measures, the diversity of testing methodologies and lack of comparative evaluations limited the ability to identify the best practice for evaluating HBM performance.

31 December 2025 in Lubricants
Verified
Journal Article
Open access
PDF file
VMVictoria P. Marino
Victoria P. Marino
FVFrancesca de Vecchi
Francesca de Vecchi
DFDominik Jonas Federl
Dominik Jonas Federl
LBLandon M Begin
Landon M Begin
ALAfton K. Limberg
Afton K. Limberg
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer
Hemiarthroplasty addresses joint damage confined to one side, preserving native cartilage and bone, but accelerated degeneration of the opposing cartilage can compromise outcomes. This systematic review should clarify whether coefficient of friction (COF) reliably predicts cartilage wear when evaluating hemiarthroplasty bearing materials (HBMs). Thirty in vitro studies reporting both outcomes were identified. Data were extracted on COF, wear, and testing parameters, and wear was standardized using a 0–4 rubric to enable cross-study comparison. Three analytical approaches were applied: linear model fits, Pearson’s correlations, and predictive modeling. Reported COFs increased significantly with testing time, while contact stress and sliding velocity showed variable associations with COF. Predictive models for cobalt–chromium (CoCr), the most studied HBM, showed moderate fit, suggesting that mechanical parameters explain only part of COF variability. For wear, linear models showed poor fit with COF, but correlations indicated positive associations with contact stress. Inconsistent effects of velocity and distance were found. Predictive models explained little variability. Together, these findings suggest that outcomes are strongly influenced by testing conditions, lubricants, and HBM selection, and COF alone is an unreliable predictor of cartilage wear in an experimental setting.