Heangwoo Lee

Prof. Heangwoo Lee

College of Design, Sangmyung University, Cheonan-si, Chungcheongnam-do, South Korea
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

HLHeangwoo Lee
Heangwoo Lee
XZXiaolong Zhao
Xiaolong Zhao
JSJanghoo Seo
Janghoo Seo
Recent studies on light shelves found that building energy efficiency could be maximized by applying photovoltaic (PV) modules to light shelf reflectors. Although PV modules generate a substantial amount of heat and change the consumption of indoor heating and cooling energy, performance evaluations carried out thus far have not considered these factors. This study validated the effectiveness of PV module light shelves and determined optimal specifications while considering heating and cooling energy savings. A full-scale testbed was built to evaluate performance according to light shelf variables. The uniformity ratio was found to improve according to the light shelf angle value and decreased as the PV module installation area increased. It was determined that PV modules should be considered in the design of light shelves as their daylighting and concentration efficiency change according to their angles. PV modules installed on light shelves were also found to change the indoor cooling and heating environment; the degree of such change increased as the area of the PV module increased. Lastly, light shelf specifications for reducing building energy, including heating and cooling energy, were not found to apply to PV modules since PV modules on light shelf reflectors increase building energy consumption.

1 October 2018 in Building and Environment
Verified
Journal Article
Closed access
HLHeangwoo Lee
Heangwoo Lee
JSJanghoo Seo
Janghoo Seo
SKSuktae Kim
Suktae Kim

11 November 2019 in Energies
Verified
Journal Article
Open access
HLHeangwoo Lee
Heangwoo Lee
JSJanghoo Seo
Janghoo Seo
CCChang-Ho Choi
Chang-Ho Choi
The consumption of lighting energy in buildings continues to rise, and many studies are being conducted to address this problem. As part of such initiatives, research is being performed on light shelves, which are natural lighting systems. However, most prior studies focused on variables for operating flat reflectors and light shelves. This study aims to evaluate the performance of curved light shelves to prove their effectiveness and derive optimal specifications for them. The following conclusions were reached. The optimal light shelf angles for a flat light shelf were found to be 30°, 20°, and 20° for the summer, mid-season, and winter, respectively, and accordingly, a movable light shelf system would be suitable for all three seasons. The optimal light shelf angles for a movable curved light shelf with an arc angle of 60° were found to be 30°, 30°, and 10° for the summer, mid-season, and winter, respectively. The optimal light shelf angle and arc angle for a fixed-type curved light shelf were found to be 20° and 60°, respectively. A fixed-type curved light shelf designed according to these optimal specifications can reduce energy consumption by 3.6% in comparison to a movable flat light shelf. Consequently, the curved light shelf is considered an effective system, and additional studies analyzing various other factors should be carried out in the future.

4 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
HLHeangwoo Lee
Heangwoo Lee
JSJanghoo Seo
Janghoo Seo
To address the increased use of lighting energy in the building sector, research on the use of light shelves has been increasing. Previous studies have focused on applying operating techniques to improve daylighting performance, which reduces the economic efficiency of light shelves and the building energy savings. This study proposes the use of prism sheets to improve the performance of light shelves, a concept which was validated by evaluating the performance related to saving building energy and improving indoor light uniformity through a full-scale testbed. This study used an external light shelf with no prism sheet, a window with a prism sheet applied, and a window with both an external light shelf and prism sheet applied as Case 1, Case 2, and Case 3, respectively, and analyzed the illuminance distribution and lighting energy consumption required to maintain the optimal indoor illumination for each case. This study also derived the optimal specifications for each case to save building energy and considered the flow of natural light to analyze the performance evaluation results. The main findings are as follows: (1) the optimal specifications to improve daylighting performance were derived for Case 1, requiring the application of operating techniques; (2) Case 2 was not suitable for saving energy and improving light uniformity when compared to Case 1; and (3) Case 3 was effective in saving building energy. In Case 3, even when the light shelf was fixed at 20° without moving, it saved building energy and improved light uniformity compared to Case 1. However, the prism sheet in Case 3 should be detached during winter to maximize building energy savings.

JOJIYOUNG OH
JIYOUNG OH
HLHeangwoo Lee
Heangwoo Lee
HPHeykyung Park
Heykyung Park
Color is the most potent stimulating factor affecting human vision, and the environmental color of an indoor space is a spatial component that affects the environmental stress level. As one of the methods of assessing the physiological response of the autonomic nervous system that influences stress, heart rate variability (HRV) has been utilized as a tool for measuring the user’s stress response in color environments. This study aims to identify the effects of the changes of hue, brightness, and saturation in environmental colors on the HRV of two groups with different stress levels—the stress potential group (n = 15) and the healthy group (n = 12)—based on their stress level indicated by the Psychosocial Well-being Index (PWI). The ln(LF), ln(HF), and RMSSD values collected during the subjects’ exposure to 12 environments colors of red and yellow with adjusted saturation and brightness, were statistically analyzed using t-test and two-way ANOVA. The results show that the HRV values in the two groups did not significantly vary in response to the changes in hue, brightness and saturation. The two groups’ stress factors distinguished according to the stress levels by the PWI scale affected the In(LF) parameter, which demonstrates that the PWI index can be utilized as a reliable scale for measuring stress levels. The ultra-short HRV measurement record and the use of a sole In(LF) parameter for stress assessment are regarded as the limitations of this study.