Janghoo Seo

Prof. Janghoo Seo


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
HLHeangwoo Lee
Heangwoo Lee
XZXiaolong Zhao
Xiaolong Zhao
JSJanghoo Seo
Janghoo Seo
Recent studies on light shelves found that building energy efficiency could be maximized by applying photovoltaic (PV) modules to light shelf reflectors. Although PV modules generate a substantial amount of heat and change the consumption of indoor heating and cooling energy, performance evaluations carried out thus far have not considered these factors. This study validated the effectiveness of PV module light shelves and determined optimal specifications while considering heating and cooling energy savings. A full-scale testbed was built to evaluate performance according to light shelf variables. The uniformity ratio was found to improve according to the light shelf angle value and decreased as the PV module installation area increased. It was determined that PV modules should be considered in the design of light shelves as their daylighting and concentration efficiency change according to their angles. PV modules installed on light shelves were also found to change the indoor cooling and heating environment; the degree of such change increased as the area of the PV module increased. Lastly, light shelf specifications for reducing building energy, including heating and cooling energy, were not found to apply to PV modules since PV modules on light shelf reflectors increase building energy consumption.

4 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
HLHeangwoo Lee
Heangwoo Lee
JSJanghoo Seo
Janghoo Seo
To address the increased use of lighting energy in the building sector, research on the use of light shelves has been increasing. Previous studies have focused on applying operating techniques to improve daylighting performance, which reduces the economic efficiency of light shelves and the building energy savings. This study proposes the use of prism sheets to improve the performance of light shelves, a concept which was validated by evaluating the performance related to saving building energy and improving indoor light uniformity through a full-scale testbed. This study used an external light shelf with no prism sheet, a window with a prism sheet applied, and a window with both an external light shelf and prism sheet applied as Case 1, Case 2, and Case 3, respectively, and analyzed the illuminance distribution and lighting energy consumption required to maintain the optimal indoor illumination for each case. This study also derived the optimal specifications for each case to save building energy and considered the flow of natural light to analyze the performance evaluation results. The main findings are as follows: (1) the optimal specifications to improve daylighting performance were derived for Case 1, requiring the application of operating techniques; (2) Case 2 was not suitable for saving energy and improving light uniformity when compared to Case 1; and (3) Case 3 was effective in saving building energy. In Case 3, even when the light shelf was fixed at 20° without moving, it saved building energy and improved light uniformity compared to Case 1. However, the prism sheet in Case 3 should be detached during winter to maximize building energy savings.

17 February 2018 in Energies
Verified
Journal Article
Open access
PDF file
SPSeonghyun Park
Seonghyun Park
JSJanghoo Seo
Janghoo Seo
Demand is soaring for data centers with advanced data-processing capabilities. In data centers with high-temperature information technology (IT) equipment, enormous cooling systems are operated year-round. To date, studies have aimed to improve the cooling efficiency of server-room units, but cooling-energy-consumption analysis considering the recirculation of exhaust air (EA) has not been researched to a sufficient degree. This study analyzed the cooling-energy saving effects considering the EA-recirculation and supply-air (SA)-temperature conditions when direct and indirect air-side economizers were applied to a data center in Korea. Thirteen case studies were conducted. The results showed that when the EA-recirculation ratio in the direct air-side economizer was 15%, its annual cooling-energy consumption increased by approximately 6.1% compared to the case with no recirculation. The indirect air-side economizer also exhibited an approximately 9% increase in cooling-energy consumption. On the other hand, when the SA temperature changed to 22 °C, the annual cooling-energy consumption of the direct and indirect air-side economizers decreased by approximately 67% and 55%, respectively, compared to a central chilled-water system. This indicates the importance of developing measures to prevent EA recirculation and of securing a wind path for the improvement of air-conditioning efficiency in data centers at the design stage.

HPHyungyu Park
Hyungyu Park
SPSeonghyun Park
Seonghyun Park
JSJanghoo Seo
Janghoo Seo
Fine particulate matter entering the body through breathing cause serious damage to humans. In South Korea, filter-type air purifiers are used to eliminate indoor fine particulate matter, and there has been a broad range of studies on the spread of fine particulate matter and air purifiers. However, earlier studies have not evaluated an operating method of air purifiers considering the inflow of fine particulate matter into the body or reduction performance of the concentration of fine particulate matter. There is a limit to controlling the concentration of fine particulate matter of the overall space where an air purifier is fixed in one spot as the source of indoor fine particulate matter is varied. Accordingly, this study analyzed changes in the concentration of indoor fine particulate matter through an experiment according to the discharging method and location of a fixed air purifier considering the inflow route of fine particulate matter into the body and their harmfulness. The study evaluated the purifiers’ performance in reducing the concentration of fine particulate matter in the occupants’ breathing zone according to the operation method in which a movable air purifier responds to the movement of occupants. The results showed the concentration of fine particulate matter around the breathing zone of the occupants had decreased by about 51 μg/m3 compared to the surrounding concentration in terms of the operating method in which an air purifier tracks occupants in real-time, and a decrease of about 68 μg/m3 in terms of the operating method in which an air purifier controls the zone. On the other hand, a real-time occupant tracking method may face a threshold due to the moving path of an air purifier and changes in the number of occupants. A zone controlling method is deemed suitable as an operating method of a movable air purifier to reduce the concentration of fine particulate matter in the breathing zone of occupants.

15 January 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HLHeangwoo Lee
Heangwoo Lee
SHSowon Han
Sowon Han
JSJanghoo Seo
Janghoo Seo
Some recent research in the area of light shelves has been focused on applying photovoltaic modules to light shelves to save building energy. However, due to the modules installed on the light shelf reflectors, most such light shelves have failed to improve both daylighting and generation efficiency. This study proposes a folding technology to improve light shelves’ daylighting and generation efficiency that uses photovoltaic modules and validates their performance using a testbed. The major obtained findings are as follows: (1) The proposed folding technology has a structure in which reflectors and photovoltaic modules fold alternately by modularizing the light shelf. The reflector and photovoltaic modules are controlled by adjusting the degree of folding. (2) Because light shelf angles for improving daylighting and generation differed depending on the application of the photovoltaic module, the optimal light shelf specifications differed. (3) Compared to previous light shelf technologies, the light shelf with folding technology and a photovoltaic module reduced energy use by 31.3% to 38.2%. This demonstrates the efficacy of the proposed system. (4) Applying a photovoltaic module can lower the indoor uniformity ratio, which means that the daylighting performance of the light shelf is degraded due to the reduction of the area occupied by the reflector.

16 April 2016 in Energies
Verified
Journal Article
Open access
PDF file
MYMin Gyung Yu
Min Gyung Yu
YNYujin Nam
Yujin Nam
YYYoungdong Yu
Youngdong Yu
JSJanghoo Seo
Janghoo Seo
Recently, the use of hybrid systems using multiple heat sources in buildings to ensure a stable energy supply and improve the system performance has gained attention. Among them, a heat pump system using both solar and ground heat was developed and various system configurations have been introduced. However, establishing a suitable design method for the solar-assisted ground heat pump (SAGHP) system including a thermal storage tank is complicated and there are few quantitative studies on the detailed system configurations. Therefore, this study developed three SAGHP system design methods considering the design factors focused on the thermal storage tank. Using dynamic energy simulation code (TRNSYS 17), individual performance analysis models were developed and long-term quantitative analysis was carried out to suggest optimum design and operation methods. As a result, it was found that SYSTEM 2 which is a hybrid system with heat storage tank for only a solar system showed the highest average heat source temperature of 14.81 °C, which is about 11 °C higher than minimum temperature in SYSTEM 3. Furthermore, the best coefficient of performance (COP) values of heat pump and system were 5.23 and 4.32 in SYSYEM 2, using high and stable solar heat from a thermal storage tank. Moreover, this paper considered five different geographical and climatic locations and the SAGHP system worked efficiently in having high solar radiation and cool climate zones and the system COP was 4.51 in the case of Winnipeg (Canada) where the highest heating demand is required.