Julia Ting

Dr. Julia Ting

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AFAli Foroutan
Ali Foroutan
DPDiwakar Phuyal
Diwakar Phuyal
GBGeorgia A M Babb
Georgia A M Babb
JTJulia Ting
Julia Ting
GMGhazal Mashhadiagha
Ghazal Mashhadiagha
GSGraham Schwarz
Graham Schwarz
Background/Objectives: Robotic technology has transformed several surgical specialties, offering enhanced precision, visualization, and dexterity. In plastic and reconstructive surgery, robotic systems are increasingly utilized across a range of procedures, though their applications remain in early development. Methods: A review of the literature was performed to identify studies reporting robot-assisted procedures in plastic and reconstructive surgery. The literature was synthesized thematically to characterize current procedural applications, emerging technologies, and areas of active clinical investigation. Results: Robotic systems have been reported in a broad range of plastic and reconstructive procedures, including flap harvest, microsurgery, breast reconstruction, craniofacial and head and neck reconstruction, esthetic surgery, and gender-affirming surgery. The existing studies primarily consist of case series and case reports with substantial variability in reported indications, techniques, and technological platforms. Comparative clinical outcomes and long-term data are limited. Conclusions: Robot-assisted reconstruction continues to expand across multiple procedural domains. However, current evidence remains largely descriptive, underscoring the need for standardized reporting and prospective studies to better define clinical value, safety, and appropriate indications.

31 October 2026 in Microsurgery
Verified
Journal Article
Open access
FPFilippo Andrea Giovanni Perozzo
Filippo Andrea Giovanni Perozzo
DPDiwakar Phuyal
Diwakar Phuyal
JTJulia Ting
Julia Ting
JGJames Owens Gaston
James Owens Gaston
LLL. Scott Levin
L. Scott Levin
AFAlberto Franchi
Alberto Franchi
Pedicle compromise after free tissue transfer typically mandates urgent surgical re‐exploration, as flap viability is considered entirely dependent on an intact vascular supply before inosculation is achieved. Whether selective conservative management can be considered in selected cases remains an open question. We report two cases of lower extremity free flap reconstruction in which presumptive late pedicle compromise—occurring on postoperative day 6 in both patients—was managed conservatively with full flap survival. Case 1 was a 71‐year‐old non‐smoking woman with hypertension who underwent coverage of a traumatic pretibial bone‐exposing defect (measuring approximately 9 × 5 cm) with a free superficial circumflex iliac artery perforator (SCIP) flap (approximately 10 × 6 cm) anastomosed to the posterior tibial perforator and a deep vein. Case 2 was a 33‐year‐old moderate smoker who underwent deep inferior epigastric perforator (DIEP) flap reconstruction (approximately 15 × 9 cm) for tibial plate exposure following a fracture fixation and wound dehiscence, anastomosed to the posterior tibial perforator and deep vein. In both cases, loss of Doppler signal and clinical ischemia on postoperative day 6 were accompanied by bedside indocyanine green (ICG) imaging demonstrating peripheral perfusion originating from the flap margins distant from the anastomosis, consistent with early neovascularization. Re‐exploration was deferred in both cases. Both flaps developed minor marginal epidermal loss without full‐thickness necrosis, and achieved complete healing within 6 weeks. Follow‐up was 6 months in both cases. These cases suggest that, in carefully selected patients with multimodal evidence of peripheral flap perfusion, conservative management of presumptive late pedicle compromise may be considered. The accompanying literature review is subject to publication bias, as only cases with successful outcomes are systematically reported; the true failure rate of conservative management cannot be estimated from available evidence. These findings are hypothesis‐generating and should not be interpreted as a new standard of care; prospective validation is required before definitive recommendations can be made.

5 October 2025 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
DPDiwakar Phuyal
Diwakar Phuyal
JTJulia Ting
Julia Ting
NHNatalie Hoffner
Natalie Hoffner
SYSara Yacoub
Sara Yacoub
ODOsama Darras
Osama Darras
HCHarvey Chim
Harvey Chim

22 September 2026 in Microsurgery
Verified
Journal Article
Closed access
JTJulia Ting
Julia Ting
DPDiwakar Phuyal
Diwakar Phuyal
CPClayton Petro
Clayton Petro
VAVictor F. A. Almeida
Victor F. A. Almeida
LBLucas Beffa
Lucas Beffa
SBSarah Bishop
Sarah Bishop

18 April 2026 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Open access
DPDiwakar Phuyal
Diwakar Phuyal
NHNatalie Hoffner
Natalie Hoffner
NYNoam Yanay
Noam Yanay
JTJulia Ting
Julia Ting
ODOsama Darras
Osama Darras
SBSarah Bishop
Sarah Bishop
The deep inferior epigastric perforator (DIEP) flap is a reliable salvage option following complications of implant-based breast reconstruction (IBR). However, comparative data on indications and outcomes between radiated and non-radiated breasts remain limited. A ten-year retrospective cohort study was performed by including patients who underwent DIEP flap reconstruction following complicated IBR. Data were compared between radiated and non-radiated breasts using the Mann-Whitney U, Chi-square, and Fisher's exact tests. Among the 1684 patients who underwent IBR, 620 (36.8%) required implant removal or exchange, and 63 (3.7%) ultimately underwent DIEP flap reconstruction. In total, 89 breasts underwent DIEP reconstruction after complications of implant, among which 33 (37%) had received post-mastectomy radiation to the ipsilateral implant or tissue expander. Radiated breasts had higher rates of infection (25% vs. 7%, p = 0.02) and implant removal (34.4% vs. 7%, p = 0.002) rates prior to DIEP conversion. The median interval between mastectomy and DIEP reconstruction tended to be shorter in radiated breasts (28 vs. 39 months, p = 0.09). Capsular contracture was the most common indication for conversion (46.9% radiated vs. 29.8% non-radiated, p = 0.1). Flap survival was 100% in radiated breasts and 96.5% in non-radiated breasts (p = 0.53). Permanent implant-to-DIEP conversion occurred in 3.7% of patients. Radiated breasts were more likely to experience infection and implant removal before conversion. Although the time to DIEP tended to be shorter in radiated patients, this was not statistically significant. DIEP flap reconstruction provides high survival in both groups, confirming its reliability as a salvage option.