魏 婷

Ms. 魏 婷


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
QLQihui Liu
Qihui Liu
魏婷魏 婷
魏 婷
XCXipeng Cai
Xipeng Cai
YZYihua Zhu
Yihua Zhu
CLChao Luo
Chao Luo
Large-scale wind-farm clusters are characterized by intense power fluctuations, various turbine types and time-varying reactive power margins, along with conflicting goals of voltage security and network loss reduction. To address these issues, this paper proposes a hierarchical coordinated reactive power optimization strategy based on an Environment-Aware Particle Swarm Optimization (EAPSO) algorithm. In this study, “environment-aware” specifically refers to operating-condition awareness, including low-load degree, spatial power dispersion, and output imbalance degree of wind turbines. A three-layer framework consisting of cluster level, wind-farm level and unit level is established to coordinate wind-farm reactive power commands, SVG outputs, transformer tap positions, and turbine-level reactive power allocation. A comprehensive disturbance index is constructed from the low-load degree, spatial power dispersion, and output imbalance degree and is then mapped to the initialization strategy, learning factors, and mutation operation of EAPSO. A 24 h offline simulation is conducted using historical operating profiles of a practical large-scale wind-farm cluster in South China. The results show that the proposed strategy reduces the average absolute PCC voltage deviation from 0.013331 p.u. before optimization to 0.004120 p.u. it achieves an average network-loss reduction rate of 3.55%. Compared with Method 1, the transformer tap operation times decrease from 139 to 92, and the cumulative SVG reactive output decreases from 1077.32 Mvar to 208.39 Mvar.

7 October 2026 in Energies
Verified
Journal Article
Open access
PDF file
XCXipeng Cai
Xipeng Cai
PHPengfei He
Pengfei He
LBLingxun Bian
Lingxun Bian
YZYihua Zhu
Yihua Zhu
QLQihui Liu
Qihui Liu
魏婷魏 婷
魏 婷
Grid-following converters are prone to transient synchronization instability during grid faults, which may lead to the disconnection of renewable energy devices and threaten the security and stability of power systems. To address this issue, this paper first establishes a second-order nonlinear reduced-order model centered on phase-locked loop dynamics and constructs an energy function to analyze the instability mechanism, revealing the decisive role of equivalent damping in the energy dissipation process. On this basis, an adaptive damping stabilization control strategy based on q-axis voltage feedback is proposed. By introducing the amplitude of the q-axis voltage into the feedback loop to reshape the damping path, the strategy can adaptively adjust the damping according to the fault severity. This control strategy significantly enhances the synchronization stability of grid-following converters: it suppresses oscillations and achieves fault ride-through during transient instability, while limiting the divergence of the power angle during static instability to buy time for fault clearing. Finally, hardware-in-the-loop experiments validate the effectiveness of the proposed strategy.