Sufang Wen

Ms. Sufang Wen


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
Ruiming LiuRuiming Liu
Ruiming Liu
SWShengtie Wang
Shengtie Wang
GLGuangchen Liu
Guangchen Liu
SWSufang Wen
Sufang Wen
JZJianwei Zhang
Jianwei Zhang
YMYuechao Ma
Yuechao Ma
This paper proposes a novel virtual inertia control (VIC) method based on a feedforward decoupling strategy to address the low inertia issue of power-converter-interfaced microgrids. The feedforward control scheme is employed to eliminate the coupling between active and reactive power caused by line impedance. The active power-voltage droop can be applied to the battery converter in the hybrid energy storage system (HESS). A novel VIC method is developed for the supercapacitor (SC) converter of HESS to increase the inertia of the microgrid. Detailed small-signal modeling of the SC converter with the proposed VIC was conducted, and the transfer function model was obtained. Parameter analysis of the virtual inertia and virtual damping was carried out with the pole-zero map method, and the step response characteristic of output voltage amplitude with power variation was analyzed in detail, deriving the parameter design principle. The simulation study verifies the effectiveness and validity of the proposed control strategy. The proposed feedforward decoupling method and VIC can be widely applied in microgrids to enhance inertia and improve their power quality.

21 May 2026 in Energies
Verified
Journal Article
Open access
PDF file
DGDahai Guo
Dahai Guo
GLGuangchen Liu
Guangchen Liu
JZJianwei Zhang
Jianwei Zhang
GTGuizhen Tian
Guizhen Tian
SWSufang Wen
Sufang Wen
YWYan Wang
Yan Wang
To address fault-period DC-link overvoltage, the reduction in grid-side active-power regulation margin caused by reactive-current-priority operation, and the double-frequency current fluctuation induced by negative-sequence components under asymmetrical grid faults in a flywheel-assisted permanent-magnet direct-drive wind power system, this paper proposes a coordinated low-voltage ride-through (LVRT) strategy based on DC-link-voltage-threshold partitioning. According to the DC-link voltage level, the operating process is divided into a normal regulation region, a grid-side saturation region, and a flywheel activation region, thereby enabling coordinated regulation between grid-side reactive-current support and flywheel-side active-power absorption. To improve transient smoothness, an anti-windup mechanism together with a bumpless transfer scheme is incorporated into the coordinated control process to suppress integrator saturation and mitigate mode-transition disturbances. In addition, a grid-side proportional–integral–vector resonant controller (PI-VRC) is introduced to improve the suppression of double-frequency current fluctuation under asymmetrical faults and enhance converter capacity utilization. Simulation results show that the proposed strategy can effectively restrain fault-period DC-link voltage rise, improve three-phase current symmetry and grid power quality, and strengthen transient reactive-power support, thereby enhancing the asymmetrical-fault LVRT capability of the system.

28 May 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DGDahai Guo
Dahai Guo
GLGuangchen Liu
Guangchen Liu
JZJianwei Zhang
Jianwei Zhang
GTGuizhen Tian
Guizhen Tian
SWSufang Wen
Sufang Wen
YWYan Wang
Yan Wang
To address DC-link voltage fluctuation, active-power imbalance between the machine side and the grid side, and double-frequency distortion in the grid current of a flywheel energy storage system (FESS) under symmetrical and asymmetrical voltage sag faults, this paper proposes a coordinated control strategy for the machine-side and grid-side converters to enhance low-voltage ride-through (LVRT) capability. Taking the DC-side energy imbalance as the coordination criterion, the machine-side converter adopts an online active-current-command reconstruction method based on cascaded limiting of DC-link voltage deviation. Under reactive-power-priority support and constrained active-power output on the grid side, the FESS can actively adjust its active-current command according to the DC-side energy state, thereby suppressing DC-link overvoltage/undervoltage and restoring the power balance between the machine side and the grid side. On the grid side, an improved linear active disturbance rejection control (LADRC) is introduced into the current inner loop. By optimizing the structure of the extended state observer, the observation and compensation capability for double-frequency disturbances is enhanced, thus improving grid-current quality under asymmetrical faults. In this way, power rebalancing between the machine side and the grid side, DC-link voltage stabilization, and grid-current disturbance suppression are incorporated into a unified coordinated control framework. Hardware-in-the-loop experimental results show that the proposed strategy can maintain DC-link voltage stability during both symmetrical and asymmetrical voltage sags, while keeping the maximum grid-current total harmonic distortion (THD) below 0.13%. Under asymmetrical voltage sag, the improved LADRC reduces the maximum interphase peak-current deviation from approximately 52 A under conventional PI control to 4.57 A, corresponding to a reduction of about 91.2%. These results indicate that the proposed strategy can effectively enhance DC-link voltage stabilization and improve grid-current quality during faults.