This paper presents a model-predictive sliding-mode control (MPSMC) scheme for a three-phase ac/dc converter to achieve better stability and dynamic performances. In the conventional model-predictive control method, a proportional-integral (PI) controller is used to generate the active power reference. This traditional model-predictive PI control (MPPIC) scheme, however, produces a large overshoot/undershoot, a long settling time, and a large steady-state error under disturbances. To overcome these deficiencies, a sliding-mode controller is employed to replace the PI controller. Since the control law and the controller are designed based on the system model, the proposed MPSMC scheme can reduce the effects of unexpected disturbances, such as the output voltage demand and the resistance load variations. Both methods have been simulated in MATLAB/Simulink during various disturbances. Compared with the performances of MPPIC, the results obtained from MPSMC show that the settling time of the dc voltage can be minimized by about 91%, and the overshoot can be eliminated from 9.13% during the steady-state progress. The active and reactive power from MPSMC can also be controlled to the desired values, respectively, with a much smaller overshoot/undershoot and a faster response speed. Similar dynamic improvements can be achieved with MPSMC when the dc voltage demand varies. The simulation results are validated by experimental results.
The hysteresis band controller offers excellent dynamic performance. It has been widely researched and applied to the voltage source inverter and inverter fed drives, however it has not been investigated within the context of a matrix converter or a matrix converter based motor drive. In this study, both fixed‐band and sinusoidal‐band hysteresis current controllers are proposed and developed for a direct matrix converter. A comprehensive comparative evaluation of the two methods is then carried out. Both methods have fast dynamic performance and they inherently integrate the line modulation technique of the virtual rectifier stage into the overall modulation. Surge currents are prevented with the proposed scheme. The sinusoidal‐band hysteresis controller demonstrates lower total harmonic distortion at the expense of higher average switching frequency, which is only significantly observable at very high sampling frequencies. The proposed controller is integrated with the field‐oriented control to drive a matrix converter fed permanent magnet synchronous machine. The proposed methods are simple and incur a light computational burden, which advances the practical applications of matrix converters in AC motor drives. The simulation and experiment results demonstrate the effectiveness and feasibility of the proposed scheme.
1 March 2019 in Chinese Journal of Electrical Engineering
This paper proposes a predictive voltage control strategy for a direct matrix converter used in a renewable energy distributed generation (DG) system. A direct matrix converter with LC filters is controlled in order to work as a stable voltage supply for loads. This is especially relevant for the stand-alone operation of a renewable DG where a stable sinusoidal voltage, with desired amplitude and frequency under various load conditions, is the main control objective. The model predictive control is employed to regulate the matrix converter so that it produces stable sinusoidal voltages for different loads. With predictive control, many other control objectives, e.g., input power factor, common-mode voltage, and switching frequency, can be achieved depending on the application. To reduce the number of required measurements and sensors, this paper utilizes observers and makes the use of the switch matrices. In addition, the voltage transfer ratio can be improved with the proposed strategy. The controller is tested under various conditions including intermittent disturbance, nonlinear loads, and unbalanced loads. The proposed controller is effective, simple, and easy to implement. The simulation and experimental results verify the effectiveness of the proposed scheme and control strategy. This proposed scheme can be potentially used in microgrid applications.
This paper presents a finite control set model predictive control (MPC) using a designed dynamic reference for bidirectional electric vehicle (EV) chargers. In the conventional MPC scheme, a PI controller is involved to generate an active power reference from the DC voltage reference. It is hard to find one fixed set of coefficients for all working conditions. In this paper, a designed dynamic reference based MPC strategy is proposed to replace the PI control loop. In the proposed method, a DC voltage dynamic reference is developed to formulate the inherent relationship between the DC voltage reference and the active power reference. Multi-objective control can be achieved in the proposed scheme, including controlling of the DC voltage, battery charging/discharging current, active power and reactive power, independently. Bidirectional power flow is operated effectively between the EV-and the grid-side. Experimental results are obtained from a laboratory three-phase two-stage bidirectional EV charger controlled by dSPACE DS1104. The results show that fast dynamic and good steady state performance of tracking the above objectives can be achieved with the proposed method. Compared with the system performance obtained by the conventional MPC method, the proposed method generates less active power ripples and produces a better grid current performance.