Steven W. Brown

Dr. Steven W. Brown


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2003 in Metrologia
Verified
Journal Article
Closed access
PDF file
SBSteven W. Brown
Steven W. Brown
BJB. Carol Johnson
B. Carol Johnson
MFMichael E Feinholz
Michael E Feinholz
MYMark A Yarbrough
Mark A Yarbrough
SFStephanie J Flora
Stephanie J Flora
DCDennis K Clark
Dennis K Clark

9 December 2015 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RBRobert A. Barnes
Robert A. Barnes
SBSteven W. Brown
Steven W. Brown
KLKeith R. Lykke
Keith R. Lykke
BGBruce Guenther
Bruce Guenther
JBJames J. Butler
James J. Butler
CMChristopher Moeller
Christopher Moeller
Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance responsivity in a two-step method. In the first step, the relative spectral response (RSR) of the instrument is determined using a nearly monochromatic light source such as a lamp-illuminated monochromator. These sources do not typically fill the field of view of the instrument nor act as calibrated sources of light. Consequently, they only provide a relative (not absolute) spectral response for the instrument. In the second step, the instrument views a calibrated source of broadband light, such as a lamp-illuminated integrating sphere. The RSR and the sphere’s absolute spectral radiance are combined to determine the absolute spectral radiance responsivity (ASR) of the instrument. More recently, a full-aperture absolute calibration approach using widely tunable monochromatic lasers has been developed. Using these sources, the ASR of an instrument can be determined in a single step on a wavelength-by-wavelength basis. From these monochromatic ASRs, the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as lamp-illuminated integrating spheres. In this work, the traditional broadband source–based calibration of the Suomi National Preparatory Project Visible Infrared Imaging Radiometer Suite sensor is compared with the laser-based calibration of the sensor. Finally, the impact of the new full-aperture laser-based calibration approach on the on-orbit performance of the sensor is considered.

2 March 2012 in Metrologia
Verified
Journal Article
Open access
YZYuqin Zong
Yuqin Zong
SBSteven W. Brown
Steven W. Brown
GEGeorge P Eppeldauer
George P Eppeldauer
KLKeith R Lykke
Keith R Lykke
YOYoshi Ohno
Yoshi Ohno

1 January 2003 in International Journal of Remote Sensing
Verified
Journal Article
Closed access
SBSteven W. Brown
Steven W. Brown
BJB. Carol Johnson
B. Carol Johnson
We have designed and built a portable integrating sphere source for use at the National Aeronautics and Space Administration (NASA) satellite sensor calibration facilities in support of the Earth Observing System (EOS) calibration programme. The source is designed to complement existing detector-based validation methodologies over the spectral range 400-2500 nm, affording extra flexibility in implementing the programme. Details of the design and operation of the portable source will be described and discussed.

23 March 2006 in Metrologia
Verified
Journal Article
Closed access
JRJ P Rice
J P Rice
SBSteven W. Brown
Steven W. Brown
BJB. Carol Johnson
B. Carol Johnson
JNJ E Neira
J E Neira

1 October 2000 in Metrologia
Verified
Journal Article
Closed access
BJB. Carol Johnson
B. Carol Johnson
SBSteven W. Brown
Steven W. Brown
HYH W Yoon
H W Yoon