We present the results of a recent, extensive measurement campaign validating the traceability of the solar irradiance record and Earth radiation budget data. The campaign also established future traceability, thus ensuring confidence in the continuing climate-data record. The total solar irradiance radiometer facility (TRF) at the Laboratory for Atmospheric and Space Physics (LASP) Boulder, uses a liquid helium cooled cryogenic radiometer as the reference standard for the validation of spaceflight total solar irradiance (TSI) instrumentation. In 2008 the radiometer was directly compared to the National Institute of Standards and Technology (NIST) Primary Optical Watt Radiometer (POWR) at a wavelength of 532.12 nm. At TSI power levels, a correction factor of 1.000 306 with an associated standard uncertainty (u) of 0.000 098, was reported for the TRF radiometer scale when using external voltage measurement electronics, and not correcting for cavity heating non-equivalence or cavity absorptance. The TRF radiometer has recently been revalidated at LASP using a POWR calibrated silicon photodiode trap transfer standard named TT4. We report a correction factor of 0.999 787, u = 0.000 285 to align the TRF radiometer scale with the current NIST POWR scale. A new room temperature reference standard radiometer was established. It measured 133 parts per million (ppm) higher than POWR using the same silicon transfer standard as above, and in a separate direct measurement, 168 ppm lower than the TRF radiometer shuttered at 400 s full shutter cycle. The difference agrees within stated uncertainties. A correction of 0.999 867, u = 0.000 247 will align the new radiometer scale with the NIST radiant power scale of POWR.
A hyperspectral image projector (HIP) is introduced that is built with liquid crystal based spatial light modulators (SLM) as opposed to micromirror arrays. The use of an SLM as a broadband intensity modulator presents several benefits to this application. With slight modifications to the SLM design, SLMs can be built for a wide range of spectral regimes, ranging from the ultraviolet (UV) to the long-wavelength infrared (LWIR). SLMs can have a large pixel pitch, significantly reducing diffraction in the mid-wavelength infrared (MWIR) and LWIR. Liquid crystal based devices offer direct analog intensity modulation, thus eliminating flicker from time sequential drive schemes. SLMs allow for an on-axis configuration, enabling a simple and compact optical layout. The design of the HIP system is broken into two parts consisting of a spectral and spatial engine. In the spectral engine a diffraction grating is used to disperse a broadband source into spectral components, where an SLM modulates the relative intensity of the components to dynamically generate complex spectra. The recombined output is fed to the spatial engine which is used to construct two-dimensional scenes. The system is used to simulate a broad range of real world environments, and will be delivered to the National Institute of Standards and Technology as an enabling tool for the development of calibration standards and performance testing techniques for multispectral and hyperspectral imagers. The focus of this paper is on a visible-band HIP system; however, related work is presented with regard to SLM use in the MWIR and LWIR.
As optical imaging modalities gain acceptance for medical diagnostics and become common in clinical applications, standardized protocols to quantitatively assess optical sensor performance are required to ensure commonality in measurements and to validate system performance. The current emphasis is on the development of 3-dimensional, tissue-simulating artifacts with optical scattering and absorption properties designed to closely mimic biological systems. These artifacts, commonly known as tissue phantoms, can be fairly complex and are tailored for each specific application. In this work, we describe a conceptually simpler, 2-dimensional digital analog to the 3-dimensional tissue phantoms that we call Digital Tissue Phantoms. The Digital Tissue Phantoms are complex, realistic, calibrated, optical projections of medically relevant images with known spectral and spatial content. By generating a defined set of Digital Tissue Phantoms, the radiometric performance of the optical imaging sensor can be quantified, based on the accuracy of measurements of the projected images. The system is dynamically programmable, which means that the same system can be used with different sets of Digital Tissue Phantoms for sensor performance metrics covering a wide range of optical medical diagnostics, from cancer and tumor detection to burn quantification.