Climate change is driven by global-scale warming, while cities additionally experience local amplification due to the urban heat island (UHI) effect (urban–rural temperature differences caused by urban form, materials, and reduced evapotranspiration). In this study, we address both dimensions by analyzing long-term near-surface climate variables and derived heat-exposure indicators for multiple South European cities and by translating climate signals into climate-suitability indicators for passive/evaporative cooling. In this study, heat-stress-relevant indicators and evaporative/adiabatic cooling opportunity across paired coastal and inland South European cities are quantified using long-term hourly reanalysis and scenario-based future projections. This paper compares coastal and inland city pairs from three regions: Nicosia and Limassol from Cyprus, Seville and Lisbon on the Iberian Peninsula, and Niš and Thessaloniki on the Balkans, to characterize recent heat stress and the prospective applications and limits of adiabatic cooling. ERA5/ERA5-Land variables from the Copernicus Climate Data Base, focusing on 2 m air temperature, 2 m dew point/relative humidity, and derived indicators: days above heat thresholds and “tropical nights”, were used to determine the differences between the local climate and compare severity of effects of global warming with respect to the specific climatic conditions of the chosen cities. Application of evaporative cooling was then tested with projections up to 2050 using Climate Consultant software, using regional temperature and humidity differences to explore comfort shifts and passive cooling applicability envelopes. Cross-city comparison of climate-suitability hours and cooling needs is included in the analysis. The novelty is a paired coastal–inland, multi-region South European design (Cyprus, Iberia, and Balkans) that combines long-term hourly reanalysis (1950–2025), scenario-based mid-century morphing, and a standardized psychrometric/adaptive-comfort framework to translate climate signals into comparable climate-suitability indicators for evaporative/adiabatic cooling across contrasting humidity regimes. The results provide planning direction by indicating that humid coastal cities should prioritize shading, reduced radiant load, ventilation/urban porosity and humidity-aware cooling, while hotter and drier inland cities retain a wider climatic window for evaporative cooling, subject to water-availability constraints.
9 December 2017 in Facta Universitatis, Series: Mechanical Engineering
The Archimedean spiral coil made of a transversely corrugated tube was exposed to radiant heating in order to represent a heat absorber of the parabolic dish solar concentrator. The main advantage of the considered innovative design solution is a coupling effect of the two passive methods for heat transfer enhancement - coiling of the flow channel and changes in surface roughness. The curvature ratio of the spiral coil varies from 0.029 to 0.234, while water and a mixture of propylene glycol and water are used as heat transfer fluids. The unique focus of this study is on specific boundary conditions since the heat flux upon the tube external surfaces varies not only in the circumferential direction, but in the axial direction as well. Instrumentation of the laboratory model of the heat absorber mounted in the radiation field includes measurement of inlet fluid flow rate, pressure drop, inlet and outlet fluid temperature and 35 type K thermocouples welded to the coil surface. A thermal analysis of the experimentally obtained data implies taking into consideration the externally applied radiation field, convective and radiative heat losses, conduction through the tube wall and convection to the internal fluid. The experimental results have shown significant enhancement of the heat transfer rate compared to spirally coiled smooth tubes, up to 240% in the turbulent flow regime.
An emergency caused by the COVID-19 pandemic affected the rethinking of existing healthcare systems. The increased need for hospital beds appeared short after the outbreak of the pandemic and the solution was to adapt the existing buildings, primarily public ones. Among all, sports buildings, i.e. sports halls were successfully used around the globe for conversion into hospitals. Topic of the paper was to investigate whether sports halls in Serbia, which were also used as temporary hospitals, are suitable for conversion in terms of energy consumption needed for achieving thermal comfort. Two case studies were analysed. The energy simulations were done using the DesignBuilder software. The results of thermal comfort summary and energy consumption led to the conclusion that this building type in Serbia could be successfully used for hospital purposes. Although the multiple increase in energy consumption was noted during the heating period, the results were within the limits required by both national and international standards.
The assessment of thermal power system reliability represents a key step towards maintaining the stability and efficiency of the system. Through the application of mathematical models, risk analysis, and maintenance strategies, it is possible to optimise system performance and reduce the risk of failures. This paper presents an assessment of the reliability of the thermal energy system in fossil fuel power plant ‘Nikola Tesla, Block B1’, based on a twelve-year failure database. By implementing the theory of reliability, based on statistics and theory of possibility, and using the simple and complex two-parameter Weibull distribution, the theoretical functions of the failure rate are determined. A significant advantage of such a study is the opportunity of an early and in-depth understanding of the logic and mechanisms of system risk behaviour, and a more precise assessment of its functioning throughout future exploitation.
The Archimedean spiral coil made of a transversely corrugated pipe represents the radiant heat absorber of a parabolic dish solar concentrator. The main advantage of the considered design is the coupling of two passive methods for heat transfer enhancement - coiling the flow channel and changing the surface roughness. The aim of this numerical study is to assess the capability of Reynolds-averaged Navier-Stokes models of different complexity (Realizable k-ε, SST k-ω and RSM Linear Pressure-Strain) to adequately represent the heat transfer phenomena in the considered complex flow geometry for wide ranges of Reynolds and Prandtl numbers. The obtained results indicate that the Realizable k-ε model with enhanced wall treatment is inadequate to simulate the heat transfer for all flow conditions, while both SST and RSM slightly overestimate experimental data in the turbulent region and are able to predict laminarisation at low Reynolds numbers. The SST model predictions are more accurate in the transitional and at the beginning of the turbulent region, irrespective of the curvature ratio. RSM predictions are generally more accurate in the turbulent region. Numericaly obtained circumferential distributions of local Nu number reveal that considered turbulence models are unable to completely anticipate the interactions between the complex flow in the basic section of the pipe and the vortex flow within the corrugations.
The objective of this paper was to study the influence of high-intensity asymmetric heat flux at the wall on pressure drop and heat transfer in the Archimedean spiral coil made of transversely corrugated tube that was exposed to radiant heating and is supposed to represent heat absorber of parabolic dish solar concentrator. The working fluids were water and a mixture of propylene glycol and water (90% and 10% by volume, respectively). An increase in the heat flux density at the pipe wall affects the increase in the pressure drop and peripherally averaged Nu number in the considered geometry in all flow regimes. The effect is most noticeable in the laminar region and monotonically decreases with increasing Reynolds number and curvature ratio. The intensification of heat transfer is less compared to the increase in pressure drop with increasing heat load at the wall. Quantitative comparison of the obtained data with results in the literature is lacking due to significant differences between the considered geometries and experimental conditions.