Paul Meaney

Dr. Paul Meaney

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2007 in Academic Radiology
Verified
Journal Article
Closed access
PMPaul Meaney
Paul Meaney
MFMargaret W. Fanning
Margaret W. Fanning
TRTimothy Raynolds
Timothy Raynolds
CFColleen J. Fox
Colleen J. Fox
QFQianqian Fang
Qianqian Fang
KPKeith D. Paulsen
Keith D. Paulsen

31 January 2017 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
PMPaul Meaney
Paul Meaney
CFColleen J. Fox
Colleen J. Fox
SGShireen Geimer
Shireen Geimer
KPKeith D. Paulsen
Keith D. Paulsen
We examine the broadband behavior of complex electrical properties of glycerin and water mixtures over the frequency range of 0.1-25.0 GHz, especially as they relate to using these liquids as coupling media for microwave tomographic imaging. Their combination is unique in that they are mutually miscible over the full range of concentrations, which allows them to be tailored to dielectric property matching for biological tissues. While the resultant mixture properties are partially driven by differences in the inherent low-frequency permittivity of each constituent, relaxation frequency shifts play a disproportionately larger role in increasing the permittivity dispersion while also dramatically increasing the effective conductivity over the frequency range of 1-3 GHz. For the full range of mixture ratios, the relaxation frequency shifts from 17.5 GHz for 0% glycerin to less than 0.1 GHz for 100% glycerin. Of particular interest is the fact that the conductivity stays above 1.0 S/m over the 1-3-GHz range for glycerin mixture ratios (70%-90% glycerin) we use for microwave breast tomography. The high level of attenuation is critical for suppressing unwanted multipath signals. This paper presents a full characterization of these liquids along with a discussion of their benefits and limitations in the context of microwave tomography.

24 April 2013 in Breast Cancer Research
Verified
Journal Article
Open access
PDF file
PMPaul Meaney
Paul Meaney
PKPeter A Kaufman
Peter A Kaufman
LMLori S Muffly
Lori S Muffly
MCMichael Click
Michael Click
SPStephen P Poplack
Stephen P Poplack
KPKeith D. Paulsen
Keith D. Paulsen
Introduction: Microwave tomography recovers images of tissue dielectric properties, which appear to be specific for breast cancer, with low-cost technology that does not present an exposure risk, suggesting the modality may be a good candidate for monitoring neoadjuvant chemotherapy. Methods: Eight patients undergoing neoadjuvant chemotherapy for locally advanced breast cancer were imaged longitudinally five to eight times during the course of treatment. At the start of therapy, regions of interest (ROIs) were identified from contrast-enhanced magnetic resonance imaging studies. During subsequent microwave examinations, subjects were positioned with their breasts pendant in a coupling fluid and surrounded by an immersed antenna array. Microwave property values were extracted from the ROIs through an automated procedure and statistical analyses were performed to assess short term (30 days) and longer term (four to six months) dielectric property changes. Results: Two patient cases (one complete and one partial response) are presented in detail and demonstrate changes in microwave properties commensurate with the degree of treatment response observed pathologically. Normalized mean conductivity in ROIs from patients with complete pathological responses was significantly different from that of partial responders (P value = 0.004). In addition, the normalized conductivity measure also correlated well with complete pathological response at 30 days (P value = 0.002). Conclusions: These preliminary findings suggest that both early and late conductivity property changes correlate well with overall treatment response to neoadjuvant therapy in locally advanced breast cancer. This result is consistent with earlier clinical outcomes that lesion conductivity is specific to differentiating breast cancer from benign lesions and normal tissue.

17 July 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
PMPaul Meaney
Paul Meaney
DGDouglas Goodwin
Douglas Goodwin
AGAmir H. Golnabi
Amir H. Golnabi
TZTian Zhou
Tian Zhou
MPMatthew Pallone
Matthew Pallone
KPKeith D. Paulsen
Keith D. Paulsen
We have acquired 2-D and 3-D microwave tomographic images of the calcaneus bones of two patients to assess correlation of the microwave properties with X-ray density measures. The two volunteers were selected because each had one leg immobilized for at least six weeks during recovery from a lower leg injury. A soft-prior regularization technique was incorporated with the microwave imaging to quantitatively assess the bulk dielectric properties within the bone region. Good correlation was observed between both permittivity and conductivity and the computed tomography-derived density measures. These results represent the first clinical examples of microwave images of the calcaneus and some of the first 3-D tomographic images of any anatomical site in the living human.

29 January 2016 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
PMPaul Meaney
Paul Meaney
AGAndrew Gregory
Andrew Gregory
JSJan Seppala
Jan Seppala
TLTapani Lahtinen
Tapani Lahtinen
We have performed a series of experiments, which demonstrate the effect of open-ended coaxial diameter on the depth of penetration. We used a two-layer configuration of a liquid and movable cylindrical piece of either Teflon or acrylic. The technique accurately demonstrates the depth in a sample for which a given probe diameter provides a reasonable measure of the bulk dielectric properties for a heterogeneous volume. In addition, we have developed a technique for determining the effective depth for a given probe diameter size. Using a set of simulations mimicking four 50- Ω coaxial cable diameters, we demonstrate that the penetration depth in both water and saline has a clear dependence on the probe diameter, but is remarkably uniform over frequency and with respect to the intervening liquid permittivity. Two different 50- Ω commercial probes were similarly tested and confirm these observations. This result has significant implications to a range of dielectric measurements, most notably in the area of tissue property studies.

17 June 2014 in BMC Medical Physics
Verified
Journal Article
Open access
PDF file
PMPaul Meaney
Paul Meaney
AGAndrew Gregory
Andrew Gregory
NENeil R Epstein
Neil R Epstein
KPKeith D. Paulsen
Keith D. Paulsen
Tissue dielectric properties are specific to physiological changes and consequently have been pursued as imaging biomarkers of cancer and other pathological disorders. However, a recent study (Phys Med Biol 52:2637–2656, 2007; Phys Med Biol 52:6093–6115, 2007), which utilized open-ended dielectric probing techniques and a previously established sensing volume, reported that the dielectric property contrast may only be 10% or less between breast cancer and normal fibroglandular tissue whereas earlier data suggested ratios of 4:1 and higher may exist. Questions about the sensing volume of this probe relative to the amount of tissue interrogated raise the distinct possibility that the conclusions drawn from that study may have been over interpreted.