Accurate quantitation of activity provides the basis for internal dosimetry of targeted radionuclide therapies. This study investigated quantitative imaging capabilities at sites with a variety of experience and equipment and assessed levels of errors in activity quantitation in Single-Photon Emission Computed Tomography (SPECT) and planar imaging. Participants from 9 countries took part in a comparison in which planar, SPECT and SPECT with X ray computed tomography (SPECT-CT) imaging were used to quantify activities of four epoxy-filled cylinders containing 133Ba, which was chosen as a surrogate for 131I. The sources, with nominal volumes of 2, 4, 6 and 23mL, were calibrated for 133Ba activity by the National Institute of Standards and Technology, but the activity was initially unknown to the participants. Imaging was performed in a cylindrical phantom filled with water. Two trials were carried out in which the participants first estimated the activities using their local standard protocols, and then repeated the measurements using a standardized acquisition and analysis protocol. Finally, processing of the imaging data from the second trial was repeated by a single centre using a fixed protocol. In the first trial, the activities were underestimated by about 15% with planar imaging. SPECT with Chang's first order attenuation correction (Chang-AC) and SPECT-CT overestimated the activity by about 10%. The second trial showed moderate improvements in accuracy and variability. Planar imaging was subject to methodological errors, e.g., in the use of a transmission scan for attenuation correction. The use of Chang-AC was subject to variability from the definition of phantom contours. The project demonstrated the need for training and standardized protocols to achieve good levels of quantitative accuracy and precision in a multicentre setting. Absolute quantification of simple objects with no background was possible with the strictest protocol to about 6% with planar imaging and SPECT (with Chang-AC) and within 2% for SPECT-CT.
16 April 2019 in Journal of Radiological Protection
Nuclear medicine (NM) procedures for diagnosis and treatment of disease are performed routinely in hospitals throughout the world. These involve preparation and administration to patients of pharmaceuticals labelled with radioactive material. There is potential for incidents to occur, involving unintended exposures of patients or staff members, throughout all stages of a procedure. The International Atomic Energy Agency (IAEA) and the World Health Organisation highlighted the need for improvement in prevention of medical radiation incidents and accidents in the Bonn Call-for-Action in 2012. An IAEA Technical Meeting was held on prevention of unintended exposures and accidents in NM in 2018 to address the issue. Exposures can take place at any time when radioactive material is being produced and used, and the risk continues after procedures have been completed. Thus there is potential for staff or members of the general public to be exposed, as well as patients. This paper sets out guidelines for incident prevention based on presentations and discussions at the meeting, and review of reports from the literature. It deals with potential incidents in in-house radionuclide production, radiopharmaceutical preparation, administration to patients, and following a procedure, as well as aspects in management of radioactive materials. Special attention has been paid to therapeutic procedures, as these have the potential to cause more harm to patients from erroneous administrations, including tissue reactions from extravasation of radiopharmaceutical, and could lead to significant contamination events. Administration of NM therapy is generally contraindicated in pregnancy. Identification of any patient who may be pregnant is crucial and it might be necessary to verify this with a pregnancy test for patients within the age band considered to be fertile. Inclusion of NM therapy incidents in the IAEA automated reporting system SAFRON is recommended. In summary, the paper aims to highlight errors that could occur during different phases of NM procedures in order to aid prevention of incidents. The value of periodic audit in evaluating systems in place on a regular basis is emphasized. Approaches to incident investigation and follow-up are described, and the need to ensure corrective action is taken to address any deficiencies stressed.
8 December 2019 in European Journal of Nuclear Medicine and Molecular Imaging
Purpose: The International Atomic Energy Agency (IAEA) decided to initiate a survey to evaluate the current status of the practice of paediatric nuclear medicine worldwide, with the focus mainly on low and middle-income countries specifically in Latin America, Eastern Europe, Africa and Asia. This investigation sought to determine if the practice in paediatric nuclear medicine in these countries differed from that indicated by the survey of the Nuclear Medicine Global Initiative (NMGI) and if nuclear medicine practitioners were following established paediatric nuclear medicine guidelines. Methods: A total of 133 institutes took part in the survey from 62 different IAEA member states within Africa (29), Asia (39), Europe (29) and Latin America (36). The four most frequent conventional (single-photon) nuclear medicine procedures were 99mTc labelled MDP, DSMA, MAG3 and pertechnetate thyroid scans. In addition, 46 centres provided data on FDG PET/CT, including exposure data for the CT component. Nearly half of the sites (48%) perform less than 200 paediatric nuclear medicine studies per year, while 11% perform more than 1000 such studies per year. Results: Administered activities largely exceeded the recommendations for most of the sites for DMSA, MAG3 and pertechnetate, while compliance with international standards was somehow better for MDP studies. For FDG PET, the results were more uniform than for conventional nuclear medicine procedures. However, the use of CT in PET/CT for paediatric nuclear medicine revealed a high variability and, in some cases, high, dose-length product (DLP) values. This observation indicates that further attention is warranted for optimizing clinical practice in FDG PET/CT. Conclusions: Overall, in most parts of the world, efforts have been undertaken to comply either with the EANM dosage card or with the North American Consensus Guidelines. However, variability in the practice of paediatric nuclear medicine still exists. The results of this survey provide valuable recommendations for a path towards global standardization of determining the amount of activity to be administered to children undergoing nuclear medicine procedures.
Background: The aim of this study was to investigate the feasibility of ultrahypofractionated radiotherapy to the prostate bed in patients with biochemical and/or clinical relapse following radical prostatectomy who were enrolled in the prospective, observational, multicentric POPART trial (NCT04831970). Methods: Patients with post-radical prostatectomy PSA levels of ≥0.1–2.0 ng/mL and/or local relapse at PSMA PET/CT or multiparametric MRI were treated with Linac-based SBRT on the prostate bed up to a total dose of 32.5 Gy in five fractions every other day (EQD21.5 = 74.2 Gy). Maximum acute toxicity was assessed using the Common Terminology Criteria for Adverse Events version 5 scale. International Consultation on Incontinence Questionnaire—Short Form (ICIQ-SF) and Prostate Cancer Index Composite for Clinical Practice (EPIC-CP) scores were assessed at baseline and during the follow-up. Results: From April 2021 to June 2022, thirty men with a median age of 72 years (range 55–82) were enrolled in three centers. The median PSA level before RT was 0.30 ng/mL (range 0.18–1.89 ng/mL). At 3 months post-treatment, no GI or ≥2 GU side effects were reported; three patients (10%) experienced Grade 1 GU toxicity. No changes in ICIQ-SF or in the urinary domains of EPIC-CP were observed, while a transient worsening was registered in the bowel domain. At the same time point, all but two patients, who progressed distantly, were found to be biochemically controlled with a median post-treatment PSA level of 0.07 ng/mL (range 0–0.48 ng/mL). Conclusions: Our preliminary findings show that SBRT can be safely extended to the postoperative setting, without an increase in short-term toxicity or a significant decline in QoL. Long-term results are needed to confirm this strategy.
High-spin states in were populated via the and reactions. The ground-state band has been extended from to 24 (tentatively 26) and a new side band is observed up to a spin of 21 (tentatively 23). A low-frequency crossing is observed in the latter band at a rotational frequency that is similar to that seen in the ground-state band. The first and second neutron alignments are also observed in . Surprisingly, these crossings occur at approximately the same frequency. Total Routhian surface and cranked shell model calculations are used in an attempt to understand this behavior.
Rationale: The International Atomic Energy Agency (IAEA) instituted a Coordinated Research Project (CRP) on the “Evaluation and Optimization of Pediatric Imaging” addressing the lack of consistency in this field. The purpose was to develop and test an optimization schema for the practices of pediatric radiology and nuclear medicine. Methods: A 5-step optimization schema was developed. Once a protocol optimization is identified, the steps are: 1) identification of the imaging situation, 2) collection of administered activity data and evaluation of the diagnostic image quality at baseline, 3) comparison of baseline administered activity data to published standards or other benchmarks, 4) identification of intervention, if necessary, 5) implementation of intervention and evaluation. Results: Within the CRP, two institutes considered optimization projects regarding nuclear medicine. In this work, renal imaging using 99mTc-DMSA projects are presented as examples. Site 1 acquired their standard 300-s static 99mTc-DMSA studies as 5-frame dynamic studies in 29 children. Frames were added to simulate different levels of administered activity. Image quality was subjectively judged on a 3-point Likert scale. A 30% reduction in administered activity with increased imaging duration (350-s) across all age groups was shown to be acceptable. This reduction was implemented and evaluated in 31 subsequent children yielding administered activities significantly lower than baseline (mean relative difference of 30% (age group 0-5 y), 37% (5-10 y) and 38% (10-15 y)). Site 2 performed a phantom study to determine the impact of lowering administered activity on image noise, indicating that administered activities could be significantly lowered if longer imaging times were used. This led to a 50-70% reduction from baseline with no loss in image quality. Conclusion: A dose optimization approach was applied successfully for several procedures commonly performed in pediatric nuclear medicine. Results are reported for renal cortical imaging using 99mTc-DMSA, leading to significant reductions in administered activity (and thus radiation dose). This optimization schema can be successfully implemented by nuclear medicine clinics seeking to improve their approach to imaging children.