This work contributes to both Romania’s and the European Union’s energy policies by highlighting the research results obtained within the Dunarea de Jos University of Galati, but also through the technological transfer of this knowledge to the industry. In order to improve the power quality of the nonlinear loads connected to the electrical grid, a three-phase shunt active power filter prototype based on the Harmonic Component Separation Method with a Low-Pass Filter was used. The active power filter is connected at the Point of Common Coupling to compensate for individual loads or even all of them simultaneously. Therefore, active power filters can be used to compensate for the power factor and reduce the harmonic distortion of power supplies, or for processes subsequently connected to additional nonlinear loads, thus improving the energy efficiency. The shunt active power filter prototype is composed of the power side (three-phase insulated gate bipolar transistor bridge, DC link capacitor precharge system, inductive filter) and the control side (gate drive circuits, control subsystems, signal acquisition system). The filter control strategy is based on the principle of separating harmonic components with a low-pass filter, implemented by the authors on the industrial prototype. In this paper, the main technical features of the industrial shunt active power filter prototype are specified. The authors of this paper involved three cascaded control loops: the DC link voltage control loop, the shunt active power filter current control loop and the phase-locked loop. Both simulation and experimental results for the shunt-type active power filter prototype were obtained. By analyzing the obtained waveforms of the power supply source in two cases (with and without an active power filter), a decrease in the total harmonic distortion was demonstrated, both the voltage harmonic distortion factor THDu and the current harmonic distortion factor THDi in the case of the active power filter connection. By using the Field-Programmed Gate Array processing platform, the powerful computational speed features were exploited to implement the active shunt power filter control on an experimental test bench. Conducting source current harmonics mitigation increased the efficiency of the power system by decreasing the respective harmonic Joule losses. The energy-saving feature led to the increased added value of the parallel active power filter. Through the performed laboratory tests, the authors demonstrated the feasibility of the proposed control solution for the industrial prototype. In accordance with the European Union’s Research and Technological Development Policy, the development of an innovation ecosystem was taken into consideration. The unified and efficient integration of all the specific actors (enterprises, research institutes, universities and entrepreneurs) in innovation was achieved.

2 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
SESilviu Epure
Silviu Epure
Răzvan ŞoleaRăzvan Şolea
Răzvan Şolea
RBRazvan Buhosu
Razvan Buhosu
CVCiprian Vlad
Ciprian Vlad
Marin George-AndreiMarin George-Andrei
Marin George-Andrei
The proliferation of power converters in modern energy production systems has led to increased harmonic content due to the commutation of active switching devices. This increase in harmonics contributes to lower system efficiency, reduced power factor, and consequently, a higher reactive power requirement. To address these issues, this paper presents both simulation and experimental results of various control strategies implemented on Parallel Voltage Source Inverters (PVSI) for harmonic mitigation. The proposed control strategies are categorized into direct and indirect control methods. The direct control techniques implemented include the instantaneous power method (PQ), the synchronous algorithm (DQ), the maximum principle method (MAX), the algorithm based on synchronization of current with the voltage positive-sequence component (SEC-POZ), and two methods employing the separating polluting components approach using a band-stop filter and a low-pass filter. The main innovation in these active power filter (APF) control strategies, compared to traditional or existing technologies, is the real-time digital implementation on high-speed platforms, specifically FPGAs. Unlike slower microcontroller-based systems with limited processing capabilities, FPGA-based implementations allow parallel processing and high-speed computation, enabling the execution of complex control algorithms with minimal latency. Additionally, the enhanced reference current generation achieved through the seven applied methods provides precise harmonic compensation under highly distorted and nonlinear load conditions. Another key advancement is the integration with Smart Grid functionalities, allowing IoT connectivity and remote diagnostics, which enhances system monitoring and operational flexibility. Following validation on an experimental test bench, these algorithms were implemented and tested on industrial APF prototypes powered by a standardized three-phase network supply. All control strategies demonstrated an effective reduction in total harmonic distortion (THD) and improvement in power factor. Experimental findings were used to provide recommendations for choosing the most effective control solution, focusing on minimizing THD and enhancing system performance.

5 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
SESilviu Epure
Silviu Epure
Răzvan ŞoleaRăzvan Şolea
Răzvan Şolea
RBRazvan Buhosu
Razvan Buhosu
CVCiprian Vlad
Ciprian Vlad
The authors of this paper highlight the creation of an experimental system for the implementation and testing of active low-voltage electronic power filters of the parallel type, with applicability in a wide range of electrical parameters. In this paper, the authors present the results obtained on an experimental test bench for power quality purposes. The experimental test bench is one of the results of a technology transfer project. One of the specific objectives of the project was to carry out industrial research and experimental development activities in order to develop a competitive, technical and economic solution for an intelligent power system, Active Power Filter (APF). Thus, this paper presents the experimental test bench for the design, implementation and testing of algorithms for current harmonics mitigation. The conceptual theoretical frame bases of both direct and indirect control have been presented by the authors. As a case study, both the simulation and experimental results of the indirect control strategy implemented on the test bench are provided. The indirect control method is chosen due to simplicity, no complex calculus requirements, and the use of a minimum number of transducers. By features comparison with modern control strategies, this study underlines the supremacy of the indirect control in active harmonics control.

23 June 2015
Verified
Book Chapter
Closed access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
RBRazvan Buhosu
Razvan Buhosu

25 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
Marin George-AndreiMarin George-Andrei
Marin George-Andrei
SESilviu Epure
Silviu Epure
RBRazvan Buhosu
Razvan Buhosu
CVCiprian Vlad
Ciprian Vlad
This paper presents a hierarchical estimator-assisted control architecture for a three-phase shunt active power filter (SAPF) for industrial power-quality improvement. The framework combines grid synchronization, harmonic-reference generation, cascaded DC-link and dq-current control, adaptive state–parameter estimation, modulation, and supervisory protection. Numerical and experimental validations are reported separately. In the final 15 kHz switching-model validation of a 400 V, 50 Hz system supplying a six-pulse rectifier load, grid-current THD is reduced from 29.50% to 0.7469%, corresponding to a 97.47% reduction, while the power factor reaches 0.99993. The DC-link voltage is regulated to 750.32 V with 0.0896% ripple. Current- and DC-link-voltage estimation RMSEs are 0.0590 A and 7.76 mV, respectively, and all defined Safe Operating Area criteria are satisfied. Joint online identification yields Rf = 0.03 ohm and Lf = 2.998 mH, with errors of +0.0164% and −0.0667%. On the 15 kHz laboratory prototype, grid-current THD decreases from 29.1% to 2.8%. The proposed architecture provides improved robustness against parameter variations and load disturbances, enhanced observability through online state reconstruction, superior energy regulation, and comprehensive diagnostic capabilities while preserving a computational structure suitable for real-time DSP and FPGA implementation in advanced industrial power-quality conditioning systems. A broader robustness and thermal-estimator validation remain subjects for future work.

19 September 2026 in Electronics
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
RBRazvan Buhosu
Razvan Buhosu
Marin George-AndreiMarin George-Andrei
Marin George-Andrei
MSMarius George Solomon
Marius George Solomon
The increasing penetration of nonlinear industrial loads, distributed renewable generation, and intelligent electrical infrastructures requires active power filters capable of simultaneously providing high-performance harmonic mitigation, reactive power compensation, coordinated operation of multiple converters, and deterministic real-time implementation. Conventional centralized shunt active power filters (SAPFs) exhibit limited scalability, while optimization-based approaches often compromise deterministic execution because of their computational complexity. To address these challenges, this paper proposes a Distributed Quantum Multi-Shunt Active Power Filter (Quantum Multi-SAPF) that combines deterministic-based local current control with asynchronous quantum-assisted supervisory optimization. The proposed architecture employs four distributed SAPF units operating under a hierarchical cyber–physical framework. The lower control layer, implemented on a MATLAB R2026a, includes all fast electrical functions—signal acquisition, SOGI-based synchronization, Clarke transformation, instantaneous p–q current reference generation, current regulation, interleaved PWM modulation, and protection—which are executed deterministically at a switching frequency of 15 kHz. The upper supervisory layer operates asynchronously at 20 Hz and formulates converter coordination as a quadratic unconstrained binary optimization (QUBO) problem solved using Quantum Approximate Optimization Algorithm (QAOA) allocation together with Variational Quantum Eigensolver (VQE) predictive correction. This multi-rate architecture separates fast electrical dynamics from slow supervisory optimization, ensuring that uncertain optimization latency does not affect converter stability. The proposed controller is validated through comprehensive switching-level simulations on the MATLAB R2026a platform. Numerical results demonstrate a reduction in source current total harmonic distortion from 24.615% to 0.142%, corresponding to a 99.423% harmonic reduction, while improving the source power factor to 0.99999 and achieving 99.999% reactive power compensation. The distributed four-SAPF synchronization network maintains coherent phase alignment among all converter units throughout the simulation, thereby supporting coordinated compensation and balanced current sharing. This synchronized operation contributes to highly accurate compensation current tracking, with an RMS tracking error of only 0.026 A, while limiting the source current unbalance to 0.026%. These results confirm the effectiveness of the distributed synchronization and local control architecture in maintaining coordinated and balanced operation of the four parallel SAPFs. The proposed interleaved modulation strategy, combined with optimized current sharing, maintains balanced converter utilization while suppressing circulating currents without requiring a dedicated circulating current controller. The proposed Distributed Quantum Multi-SAPF establishes a scalable framework that combines deterministic industrial control with quantum-assisted supervisory optimization. The architecture provides high harmonic compensation capability, near-unity power factor, balanced converter utilization, comprehensive Safe Operating Area supervision, and practical industrial feasibility, making it a promising solution for future smart grids, renewable energy integration, electric vehicle charging infrastructures, and intelligent power quality conditioning systems.