Silviu Epure

Mr. Silviu Epure

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
SESilviu Epure
Silviu Epure
Răzvan ŞoleaRăzvan Şolea
Răzvan Şolea
RBRazvan Buhosu
Razvan Buhosu
This work contributes to both Romania’s and the European Union’s energy policies by highlighting the research results obtained within the Dunarea de Jos University of Galati, but also through the technological transfer of this knowledge to the industry. In order to improve the power quality of the nonlinear loads connected to the electrical grid, a three-phase shunt active power filter prototype based on the Harmonic Component Separation Method with a Low-Pass Filter was used. The active power filter is connected at the Point of Common Coupling to compensate for individual loads or even all of them simultaneously. Therefore, active power filters can be used to compensate for the power factor and reduce the harmonic distortion of power supplies, or for processes subsequently connected to additional nonlinear loads, thus improving the energy efficiency. The shunt active power filter prototype is composed of the power side (three-phase insulated gate bipolar transistor bridge, DC link capacitor precharge system, inductive filter) and the control side (gate drive circuits, control subsystems, signal acquisition system). The filter control strategy is based on the principle of separating harmonic components with a low-pass filter, implemented by the authors on the industrial prototype. In this paper, the main technical features of the industrial shunt active power filter prototype are specified. The authors of this paper involved three cascaded control loops: the DC link voltage control loop, the shunt active power filter current control loop and the phase-locked loop. Both simulation and experimental results for the shunt-type active power filter prototype were obtained. By analyzing the obtained waveforms of the power supply source in two cases (with and without an active power filter), a decrease in the total harmonic distortion was demonstrated, both the voltage harmonic distortion factor THDu and the current harmonic distortion factor THDi in the case of the active power filter connection. By using the Field-Programmed Gate Array processing platform, the powerful computational speed features were exploited to implement the active shunt power filter control on an experimental test bench. Conducting source current harmonics mitigation increased the efficiency of the power system by decreasing the respective harmonic Joule losses. The energy-saving feature led to the increased added value of the parallel active power filter. Through the performed laboratory tests, the authors demonstrated the feasibility of the proposed control solution for the industrial prototype. In accordance with the European Union’s Research and Technological Development Policy, the development of an innovation ecosystem was taken into consideration. The unified and efficient integration of all the specific actors (enterprises, research institutes, universities and entrepreneurs) in innovation was achieved.

2 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
SESilviu Epure
Silviu Epure
Răzvan ŞoleaRăzvan Şolea
Răzvan Şolea
RBRazvan Buhosu
Razvan Buhosu
CVCiprian Vlad
Ciprian Vlad
Marin George-AndreiMarin George-Andrei
Marin George-Andrei
The proliferation of power converters in modern energy production systems has led to increased harmonic content due to the commutation of active switching devices. This increase in harmonics contributes to lower system efficiency, reduced power factor, and consequently, a higher reactive power requirement. To address these issues, this paper presents both simulation and experimental results of various control strategies implemented on Parallel Voltage Source Inverters (PVSI) for harmonic mitigation. The proposed control strategies are categorized into direct and indirect control methods. The direct control techniques implemented include the instantaneous power method (PQ), the synchronous algorithm (DQ), the maximum principle method (MAX), the algorithm based on synchronization of current with the voltage positive-sequence component (SEC-POZ), and two methods employing the separating polluting components approach using a band-stop filter and a low-pass filter. The main innovation in these active power filter (APF) control strategies, compared to traditional or existing technologies, is the real-time digital implementation on high-speed platforms, specifically FPGAs. Unlike slower microcontroller-based systems with limited processing capabilities, FPGA-based implementations allow parallel processing and high-speed computation, enabling the execution of complex control algorithms with minimal latency. Additionally, the enhanced reference current generation achieved through the seven applied methods provides precise harmonic compensation under highly distorted and nonlinear load conditions. Another key advancement is the integration with Smart Grid functionalities, allowing IoT connectivity and remote diagnostics, which enhances system monitoring and operational flexibility. Following validation on an experimental test bench, these algorithms were implemented and tested on industrial APF prototypes powered by a standardized three-phase network supply. All control strategies demonstrated an effective reduction in total harmonic distortion (THD) and improvement in power factor. Experimental findings were used to provide recommendations for choosing the most effective control solution, focusing on minimizing THD and enhancing system performance.

5 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
SESilviu Epure
Silviu Epure
Răzvan ŞoleaRăzvan Şolea
Răzvan Şolea
RBRazvan Buhosu
Razvan Buhosu
CVCiprian Vlad
Ciprian Vlad
The authors of this paper highlight the creation of an experimental system for the implementation and testing of active low-voltage electronic power filters of the parallel type, with applicability in a wide range of electrical parameters. In this paper, the authors present the results obtained on an experimental test bench for power quality purposes. The experimental test bench is one of the results of a technology transfer project. One of the specific objectives of the project was to carry out industrial research and experimental development activities in order to develop a competitive, technical and economic solution for an intelligent power system, Active Power Filter (APF). Thus, this paper presents the experimental test bench for the design, implementation and testing of algorithms for current harmonics mitigation. The conceptual theoretical frame bases of both direct and indirect control have been presented by the authors. As a case study, both the simulation and experimental results of the indirect control strategy implemented on the test bench are provided. The indirect control method is chosen due to simplicity, no complex calculus requirements, and the use of a minimum number of transducers. By features comparison with modern control strategies, this study underlines the supremacy of the indirect control in active harmonics control.

29 July 2026 in Electricity
Verified
Journal Article
Open access
PDF file
Marin George-AndreiMarin George-Andrei
Marin George-Andrei
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
ABAdriana Burlibasa
Adriana Burlibasa
SESilviu Epure
Silviu Epure
CVCiprian Vlad
Ciprian Vlad
GPGeorge Petrea
George Petrea
This paper presents a low-cost embedded monitoring system for real-time RMS voltage and RMS current acquisition in three-phase electrical networks. The proposed architecture is based on distributed Arduino Nano acquisition nodes equipped with ACS712 Hall-effect current sensors and isolated voltage transformers, while a Raspberry Pi 4 Model B is used as a centralized data acquisition and processing unit through the I2C communication protocol. The embedded acquisition nodes implement timer-controlled analog signal sampling using the internal 10-bit ADC of the ATmega328P microcontroller, allowing real-time acquisition of electrical waveforms for RMS computation. Unlike conventional low-cost IoT electrical monitoring systems focused mainly on basic parameter visualization and wireless communication, the proposed platform emphasizes synchronized three-phase RMS monitoring and experimental validation accuracy under real operating conditions. The proposed monitoring architecture is experimentally benchmarked against a FLUKE 435 professional power quality analyser used as a high-accuracy reference instrument. Experimental results demonstrate that the proposed low-cost embedded architecture can provide RMS voltage and RMS current measurements with acceptable accuracy for educational applications, experimental electrical platforms, and distributed IoT-based monitoring systems. The presented system does not aim to implement a fully IEC 61000-4-30-compliant power quality analyser but rather to validate the feasibility of low-cost embedded RMS monitoring architectures for real-time electrical applications.

1 October 2017
Verified
Conference Paper
Closed access
SESilviu Epure
Silviu Epure
CVCiprian Vlad
Ciprian Vlad
RPRomeo Paduraru
Romeo Paduraru
A DC/DC converter that can be used to charge a lead-acid battery bank from a wide variety of input renewable sources is presented. The motherboard of the converter can be populated in such way that a boost or a SEPIC (Single-Ended Primary-Inductor Converter) structure is obtained. In order to lower the stress on the electronic components, the converter uses four DC/DC stages connected in parallel and driven with interleaved PWM signals. The main advantage resides in the fact that all parameters of the control loops as well as the nominal values for input and output electrical values can be adjusted by the final user. Two converters were built and tested simultaneously inside a low power distributed system, implementing MPPT algorithm. Key aspects of the low level hardware implementation and component dimensioning will be detailed.

19 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ABAdriana Burlibasa
Adriana Burlibasa
SESilviu Epure
Silviu Epure
MCMihai Culea
Mihai Culea
CDCristinel Radu Dache
Cristinel Radu Dache
CLCristian Lungu
Cristian Lungu
CVCiprian Vlad
Ciprian Vlad
Accurate time synchronization is essential in distributed electrical signal monitoring, where phase coherence and event correlation depend on precise timing agreement between acquisition nodes. Conventional approaches often rely on a single synchronization source, typically internet-based Network Time Protocol (NTP) or GPS-disciplined clocks, which is impractical in isolated, offline, or cost-sensitive scenarios. This paper introduces an autonomous offline synchronization architecture for multi-node monitoring systems built on Raspberry Pi 5 (RPI5) platforms connected to a private Ethernet network. Instead of depending on one timing method, the system integrates several complementary mechanisms: battery-backed RTC persistence via the J5 interface, deterministic orchestration through systemd services, automated boot time recovery, chrony-managed NTP discipline, and Precision Time Protocol (PTP) hardware timestamping using PTP Hardware Clock (PHC). Synchronization performance is validated through continuous multi-day measurements of long-term stability, inter-node phase coherence, and short-term jitter. Controlled power-loss scenarios are also included to verify recovery behavior. The system maintains sub-microsecond alignment between nodes using only commodity hardware and no external time source. To further confirm inter-node timestamp alignment at the signal level, both hardware-based reference signal injection and software-based synchronized signal emulation are employed, providing ground-truth validation alongside scalable and reproducible evaluation. The results show that low-cost embedded hardware can support reliable, long-duration synchronization in fully offline installations.