Abdulaziz Gul

Dr. Abdulaziz Gul

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2024 in Journal of Dentistry
Verified
Journal Article
Open access
AGAbdulaziz Gul
Abdulaziz Gul
EPEvaggelia Papia
Evaggelia Papia
ANAron Naimi-Akbar
Aron Naimi-Akbar
ARAmund Ruud
Amund Ruud
PSPer Vult von Steyern
Per Vult von Steyern
To evaluate the clinical outcome of different designs of zirconia dental implants. This systematic review adhered to the PRISMA checklist and followed the PICO framework. The protocol is registered in PROSPERO (CRD42022337228). The search was conducted in March 2023 through four databases (PubMed, Web of Science, Cochrane Library, and Google Scholar) along with a search of references in the related reviews. Three authors reviewed on title, and abstract level and analysed the risk of bias, and all authors reviewed on a full-text level. Clinical studies excluding case reports for patients treated with different designs of zirconia dental implants were included. From a total of 2728 titles, 71 full-text studies were screened, and 27 studies were included to assess the risk of bias (ROBINS-I tool) and data extraction. After quality assessment, four studies were included, and the remaining 23 excluded studies were narratively described. The included prospective studies with moderate risk of bias reported success and survival rates of one-piece implants that ranged between 95 and 98.4 % with no difference between different lengths and diameters. The acid-etched roughened surface showed higher clinical outcomes compared to other surface roughness designs. Promising 5-year clinical outcomes were found for one-piece zirconia implants with no difference between different diameters and lengths. Concerning surface roughness, better outcomes were found when using the acid-etched implant surface. However, due to the limited available studies, further high-quality clinical studies comparing zirconia one-piece and two-piece implants with different diameters, lengths, and surface roughness are needed. Based on this systematic review, under suitable clinical situations, the one-piece zirconia implants with diameters of 4.0 mm, 4.5 mm, or 5.5 mm and lengths of 8 mm, 10 mm, 12 mm, or 14 mm have similar promising clinical outcomes. Additionally, the acid-etched roughened implant surface may be preferable.

13 June 2026 in Clinical Oral Implants Research
Verified
Journal Article
Open access
AGAbdulaziz Gul
Abdulaziz Gul
EPEvaggelia Papia
Evaggelia Papia
SESiamak Eqtesadi
Siamak Eqtesadi
MAMagnus Anderson
Magnus Anderson
JBJonas P. Becktor
Jonas P. Becktor
PSPer Vult von Steyern
Per Vult von Steyern
Objectives: To evaluate the fracture resistance, fracture modes, and crystalline phase changes of zirconia one‐piece implants (OPI) and bone‐level (BLTPI) or tissue‐level, two‐piece implants (TLTPI), with ceramic (C) or titanium (T) abutment screws after dynamic preloading in a moist environment. Materials and Methods: Dynamic preloading under moist conditions and subsequent static load‐to‐fracture testing were performed to evaluate fracture resistance and fracture mode. Scanning electron microscopy (SEM) analysis of fracture surfaces was employed to supplement the observations of macroscopic fracture modes. Crystalline phase changes were assessed using micro‐Raman spectroscopy. Specimen preparations were performed in accordance with ISO 14801:2016. Five different ceramic (zirconia) implant designs were divided into the following groups: OPI, BLTPI (BLC, BLT), TLTPI (TLC, TLT). One‐way and two‐way ANOVA tests were used for comparisons and factor effect analysis. Results: Fracture resistance (N) and bending moment (N cm) differed significantly among the implant groups ( p < 0.001), following the order TLTPI (775.2 ± 71 N) > OPI (605.7 ± 37 N) > BLTPI (498.3 ± 93 N). Within the two‐piece implants (TPI), tissue‐level designs (TL) outperformed bone‐level designs (BL), while designs with different abutment screw materials showed no significant difference ( p = 0.982). Conclusions: Within the limitations of this in vitro study, the evaluated zirconia‐based OPI, BLTPI, and TLTPI systems demonstrate sufficient fracture resistance to support further clinical investigation. Implant‐level design (TL vs. BL) influences mechanical performance, whereas the influence of abutment screw material (ceramic vs. titanium) is less pronounced and varies according to the implant‐level design.

23 April 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AGAbdulaziz Gul
Abdulaziz Gul
EBEmil Bureau
Emil Bureau
JBJonas P Becktor
Jonas P Becktor
PSPer Vult von Steyern
Per Vult von Steyern
EPEvaggelia Papia
Evaggelia Papia
Background: Various designs of dental implants made of zirconium dioxide (zirconia) as an alternative to titanium implants are available as one-piece implant (OPI) or as bone-level or tissue-level two-piece implants (TPI) with either ceramic or titanium abutment screw types of implant-abutment connections. This study aimed to identify and quantify stress concentrations and levels across different zirconia implant designs under a quasi-static external load. Methods: The study used a finite element analysis (FEA) simulation model, including five zirconia implant design models of OPI and bone-level and tissue-level TPI zirconia implants with either ceramic or titanium abutment screw, to calculate and locate maximum principal (σ 1 ) and minimum principal (σ 3 ) and equivalent (von Mises) stresses under 400N of quasi-static loading at a 30-degree angle within ISO14801:2016 geometry and boundary conditions. The FEA assumed linear elastic and isotropic material properties. Results: OPI showed high stress concentrations at the implant body’s external thread above the specimen holder. TPIs showed similar maximum principal stress (σ 1 ) areas in their implant body, while minimum principal stress (σ 3 ) occurred in the implant–abutment interface at the abutment neck, and the corresponding area in the implant platform. The TPIs with ceramic screws exhibited the highest stresses at the screw–abutment interface. Conclusions: Within the limitations of this study, under a static oblique load applied within the ISO 14801:2016 geometry condition, stress distributions differ between OPI and TPI. TPIs show lower stress within the implant body but higher stress transfer to the specimen holder compared with OPI. Tissue-level TPIs exhibit lower stress than bone-level designs, whereas stresses in the abutment and screw depend on screw design and material. TPIs with ceramic screws exhibit higher stress levels compared to titanium screw.

9 October 2026
Verified
Thesis
Closed access
AGAbdulaziz Gul
Abdulaziz Gul
In recent years, zirconia dental implants have been attracting increasingly more recognition and interest. Commercially, these implants are available in either one- piece (OPI) or two-piece (TPI) designs. The TPI design is categorised as either bone- level (BL) or tissue-level (TL) and is connected to the abutment with either a titanium or a ceramic abutment screw. Due to zirconia's brittle nature and high elastic modulus, the design of zirconia implants and their implant to abutment connection may influence load transfer from the prosthesis to the implant and surrounding bone, thereby affecting stress distribution, fracture resistance, and ultimately clinical survival. Existing research on stress distribution, fracture resistance, and clinical outcomes of various zirconia implant designs and material combinations is limited. Therefore, this thesis aims to evaluate the clinical outcomes, stress concentrations, and fracture resistance of different designs of zirconia dental implants. In line with the aim, the thesis comprises three studies: Study I – A systematic review of clinical studies that evaluated the clinical outcomes of various zirconia implant designs. The findings showed that the one-piece implant had a promising 5-year clinical survival rate (95%), with no difference across implant diameters and lengths. The design with an acid-etched surface showed higher survival compared to other surfaces. Study II – A finite element analysis that evaluated the location of high-stress levels and concentrations in various zirconia implant designs. The findings showed that OPI and TPI designs showed differing stress distributions. TPIs demonstrated lower stress within the implant body but higher stress transfer to the specimen holder. Among TPI designs, Implant level (TL vs BL) and abutment screw design/material influenced the stress distribution within the implant–abutment complex. Study III – An in vitro laboratory study that evaluated the fracture resistance, fracture mode, and crystal phase change after dynamic preloading of various zirconia dental implant designs. The findings showed that the evaluated zirconia-based OPI, BLTPI, and TLTPI systems possessed adequate fracture resistance for further clinical evaluation. Fracture resistance and fracture mode were influenced by implant-level design (TL vs BL), whereas the abutment screw design/material (ceramic vs titanium) had a less pronounced influence and depended on the implant- level design. Overall, within the limitations of this thesis, zirconia dental implants should not be regarded as a uniform category. Differences in implant design, including OPI and TPI, TL and BL configurations, and implant–abutment connection design, influence clinical outcomes, stress distribution, and fracture resistance. Clinical evidence is currently better established for OPI, which has shown promising clinical outcomes, while evidence for TPI remains limited. Mechanically, TL TPI shows the highest fracture resistance among the evaluated designs. However, further long-term clinical studies are needed to confirm these findings, particularly for TPI.