In recent years, zirconia dental implants have been attracting increasingly more recognition and interest. Commercially, these implants are available in either one- piece (OPI) or two-piece (TPI) designs. The TPI design is categorised as either bone- level (BL) or tissue-level (TL) and is connected to the abutment with either a titanium or a ceramic abutment screw. Due to zirconia's brittle nature and high elastic modulus, the design of zirconia implants and their implant to abutment connection may influence load transfer from the prosthesis to the implant and surrounding bone, thereby affecting stress distribution, fracture resistance, and ultimately clinical survival. Existing research on stress distribution, fracture resistance, and clinical outcomes of various zirconia implant designs and material combinations is limited. Therefore, this thesis aims to evaluate the clinical outcomes, stress concentrations, and fracture resistance of different designs of zirconia dental implants. In line with the aim, the thesis comprises three studies: Study I – A systematic review of clinical studies that evaluated the clinical outcomes of various zirconia implant designs. The findings showed that the one-piece implant had a promising 5-year clinical survival rate (95%), with no difference across implant diameters and lengths. The design with an acid-etched surface showed higher survival compared to other surfaces. Study II – A finite element analysis that evaluated the location of high-stress levels and concentrations in various zirconia implant designs. The findings showed that OPI and TPI designs showed differing stress distributions. TPIs demonstrated lower stress within the implant body but higher stress transfer to the specimen holder. Among TPI designs, Implant level (TL vs BL) and abutment screw design/material influenced the stress distribution within the implant–abutment complex. Study III – An in vitro laboratory study that evaluated the fracture resistance, fracture mode, and crystal phase change after dynamic preloading of various zirconia dental implant designs. The findings showed that the evaluated zirconia-based OPI, BLTPI, and TLTPI systems possessed adequate fracture resistance for further clinical evaluation. Fracture resistance and fracture mode were influenced by implant-level design (TL vs BL), whereas the abutment screw design/material (ceramic vs titanium) had a less pronounced influence and depended on the implant- level design. Overall, within the limitations of this thesis, zirconia dental implants should not be regarded as a uniform category. Differences in implant design, including OPI and TPI, TL and BL configurations, and implant–abutment connection design, influence clinical outcomes, stress distribution, and fracture resistance. Clinical evidence is currently better established for OPI, which has shown promising clinical outcomes, while evidence for TPI remains limited. Mechanically, TL TPI shows the highest fracture resistance among the evaluated designs. However, further long-term clinical studies are needed to confirm these findings, particularly for TPI.