As one of the most popular approaches in artificial intelligence, deep learning (DL) has attracted a lot of attention in the medical physics field over the past few years. The goals of this topical review article are twofold. First, we will provide an overview of the method to medical physics researchers interested in DL to help them start the endeavor. Second, we will give in-depth discussions on the DL technology to make researchers aware of its potential challenges and possible solutions. As such, we divide the article into two major parts. The first part introduces general concepts and principles of DL and summarizes major research resources, such as computational tools and databases. The second part discusses challenges faced by DL, present available methods to mitigate some of these challenges, as well as our recommendations.
Inverse treatment planning in radiation therapy is formulated as solving optimization problems. The objective function and constraints consist of multiple terms designed for different clinical and practical considerations. Weighting factors of these terms are needed to define the optimization problem. While a treatment planning optimization engine can solve the optimization problem with given weights, adjusting the weights to yield a high-quality plan is typically performed by a human planner. Yet the weight-tuning task is labor intensive, time consuming, and it critically affects the final plan quality. An automatic weight-tuning approach is strongly desired. The procedure of weight adjustment to improve the plan quality is essentially a decision-making problem. Motivated by the tremendous success in deep learning for decision making with human-level intelligence, we propose a novel framework to adjust the weights in a human-like manner. This study used inverse treatment planning in high-dose-rate brachytherapy (HDRBT) for cervical cancer as an example. We developed a weight-tuning policy network (WTPN) that observes dose volume histograms of a plan and outputs an action to adjust organ weighting factors, similar to the behaviors of a human planner. We trained the WTPN via end-to-end deep reinforcement learning. Experience replay was performed with the epsilon greedy algorithm. After training was completed, we applied the trained WTPN to guide treatment planning of five testing patient cases. It was found that the trained WTPN successfully learnt the treatment planning goals and was able to guide the weight tuning process. On average, the quality score of plans generated under the WTPN’s guidance was improved by ~8.5% compared to the initial plan with arbitrarily set weights, and by 10.7% compared to the plans generated by human planners. To our knowledge, this was the first time that a tool was developed to adjust organ weights for the treatment planning optimization problem in a human-like fashion based on intelligence learnt from a training process, which was different from existing strategies based on pre-defined rules. The study demonstrated potential feasibility to develop intelligent treatment planning approaches via deep reinforcement learning.
Purpose: In the treatment planning process of intensity‐modulated radiation therapy (IMRT), a human planner operates the treatment planning system (TPS) to adjust treatment planning parameters, for example, dose volume histogram (DVH) constraints’ locations and weights, to achieve a satisfactory plan for each patient. This process is usually time‐consuming, and the plan quality depends on planer’s experience and available planning time. In this study, we proposed to model the behaviors of human planners in treatment planning by a deep reinforcement learning (DRL)‐based virtual treatment planner network (VTPN), such that it can operate the TPS in a human‐like manner for treatment planning.Methods and Materials: Using prostate cancer IMRT as an example, we established the VTPN using a deep neural network developed. We considered an in‐house optimization engine with a weighted quadratic objective function. Virtual treatment planner network was designed to observe an intermediate plan DVHs and decide the action to improve the plan by changing weights and threshold dose in the objective function. We trained the VTPN in an end‐to‐end DRL process in 10 patient cases. A plan score was used to measure plan quality. We demonstrated the feasibility and effectiveness of the trained VTPN in another 64 patient cases.Results: Virtual treatment planner network was trained to spontaneously learn how to adjust treatment planning parameters to generate high‐quality treatment plans. In the 64 testing cases, with initialized parameters, quality score was 4.97 (±2.02), with 9.0 being the highest possible score. Using VTPN to perform treatment planning improved quality score to 8.44 (±0.48).Conclusions: To our knowledge, this was the first time that intelligent treatment planning behaviors of human planner in external beam IMRT are autonomously encoded in an artificial intelligence system. The trained VTPN is capable of behaving in a human‐like way to produce high‐quality plans.
5 April 2018 in IEEE Transactions on Medical Imaging
A number of image-processing problems can be formulated as optimization problems. The objective function typically contains several terms specifically designed for different purposes. Parameters in front of these terms are used to control the relative importance among them. It is of critical importance to adjust these parameters, as quality of the solution depends on their values. Tuning parameters are a relatively straight forward task for a human, as one can intuitively determine the direction of parameter adjustment based on the solution quality. Yet manual parameter tuning is not only tedious in many cases, but also becomes impractical when a number of parameters exist in a problem. Aiming at solving this problem, this paper proposes an approach that employs deep reinforcement learning to train a system that can automatically adjust parameters in a human-like manner. We demonstrate our idea in an example problem of optimization-based iterative computed tomography (CT) reconstruction with a pixel-wise total-variation regularization term. We set up a parameter-tuning policy network (PTPN), which maps a CT image patch to an output that specifies the direction and amplitude by which the parameter at the patch center is adjusted. We train the PTPN via an end-to-end reinforcement learning procedure. We demonstrate that under the guidance of the trained PTPN, reconstructed CT images attain quality similar or better than those reconstructed with manually tuned parameters.
The dual-energy CT-based (DECT) approach holds promise in reducing the overall uncertainty in proton stopping-power-ratio (SPR) estimation as compared to the conventional stoichiometric calibration approach. The objective of this study was to analyze the factors contributing to uncertainty in SPR estimation using the DECT-based approach and to derive a comprehensive estimate of the range uncertainty associated with SPR estimation in treatment planning. Two state-of-the-art DECT-based methods were selected and implemented on a Siemens SOMATOM Force DECT scanner. The uncertainties were first divided into five independent categories. The uncertainty associated with each category was estimated for lung, soft and bone tissues separately. A single composite uncertainty estimate was eventually determined for three tumor sites (lung, prostate and head-and-neck) by weighting the relative proportion of each tissue group for that specific site. The uncertainties associated with the two selected DECT methods were found to be similar, therefore the following results applied to both methods. The overall uncertainty (1 σ ) in SPR estimation with the DECT-based approach was estimated to be 3.8%, 1.2% and 2.0% for lung, soft and bone tissues, respectively. The dominant factor contributing to uncertainty in the DECT approach was the imaging uncertainties, followed by the DECT modeling uncertainties. Our study showed that the DECT approach can reduce the overall range uncertainty to approximately 2.2% (2 σ ) in clinical scenarios, in contrast to the previously reported 1%.
25 November 2019 in International Journal of Computer Assisted Radiology and Surgery