Dan Nguyen

Dan Nguyen

Auto-generated profile, based on publicly available information

Dan Nguyen

Medical Artificial Intelligence and Automation Laboratory Department of Radiation Oncology University of Texas Southwestern Medical Center Dallas Texas USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2021 in Physica Medica
Verified
Journal Article
Closed access
AMAna Maria Barragan Montero
Ana Maria Barragan Montero
UJUmair Javaid
Umair Javaid
GVGilmer Valdés
Gilmer Valdés
DNDan Nguyen
Dan Nguyen
PDPaul Desbordes
Paul Desbordes
JLJohn A. Lee
John A. Lee

1 March 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
DNDan Nguyen
Dan Nguyen
XJXun Jia
Xun Jia
DSDavid Sher
David Sher
MLMu-Han Lin
Mu-Han Lin
ZIZohaib Iqbal
Zohaib Iqbal
SJSteve B Jiang
Steve B Jiang
The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human expertise and a tremendous amount of effort to produce personalized high quality plans, taking as long as a week, which deteriorates the chances of tumor control and patient survival. To solve this problem, we propose to investigate a deep learning-based dose prediction model, Hierarchically Densely Connected U-net, based on two highly popular network architectures: U-net and DenseNet. We find that this new architecture is able to accurately and efficiently predict the dose distribution, outperforming the other two models, the Standard U-net and DenseNet, in homogeneity, dose conformity, and dose coverage on the test data. Averaging across all organs at risk, our proposed model is capable of predicting the organ-at-risk max dose within 6.3% and mean dose within 5.1% of the prescription dose on the test data. The other models, the Standard U-net and DenseNet, performed worse, having an averaged organ-at-risk max dose prediction error of 8.2% and 9.3%, respectively, and averaged mean dose prediction error of 6.4% and 6.8%, respectively. In addition, our proposed model used 12 times less trainable parameters than the Standard U-net, and predicted the patient dose 4 times faster than DenseNet.

31 January 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DNDan Nguyen
Dan Nguyen
TLTroy Long
Troy Long
XJXun Jia
Xun Jia
WLWeiguo Lu
Weiguo Lu
XGXuejun Gu
Xuejun Gu
SJSteve Jiang
Steve Jiang
With the advancement of treatment modalities in radiation therapy for cancer patients, outcomes have improved, but at the cost of increased treatment plan complexity and planning time. The accurate prediction of dose distributions would alleviate this issue by guiding clinical plan optimization to save time and maintain high quality plans. We have modified a convolutional deep network model, U-net (originally designed for segmentation purposes), for predicting dose from patient image contours of the planning target volume (PTV) and organs at risk (OAR). We show that, as an example, we are able to accurately predict the dose of intensity-modulated radiation therapy (IMRT) for prostate cancer patients, where the average Dice similarity coefficient is 0.91 when comparing the predicted vs. true isodose volumes between 0% and 100% of the prescription dose. The average value of the absolute differences in [max, mean] dose is found to be under 5% of the prescription dose, specifically for each structure is [1.80%, 1.03%](PTV), [1.94%, 4.22%](Bladder), [1.80%, 0.48%](Body), [3.87%, 1.79%](L Femoral Head), [5.07%, 2.55%](R Femoral Head), and [1.26%, 1.62%](Rectum) of the prescription dose. We thus managed to map a desired radiation dose distribution from a patient’s PTV and OAR contours. As an additional advantage, relatively little data was used in the techniques and models described in this paper.

1 June 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
XLXiao Liang
Xiao Liang
LCLiyuan Chen
Liyuan Chen
DNDan Nguyen
Dan Nguyen
ZZZhiguo Zhou
Zhiguo Zhou
XGXuejun Gu
Xuejun Gu
SJSteve B Jiang
Steve B Jiang
Throughout the course of delivering a radiation therapy treatment, which may take several weeks, a patient’s anatomy may change drastically, and adaptive radiation therapy (ART) may be needed. Cone-beam computed tomography (CBCT), which is often available during the treatment process, can be used for both patient positioning and ART re-planning. However, due to the prominent amount of noise, artifacts, and inaccurate Hounsfield unit (HU) values, the dose calculation based on CBCT images could be inaccurate for treatment planning. One way to solve this problem is to convert CBCT images to more accurate synthesized CT (sCT) images. In this work, we have developed a cycle-consistent generative adversarial network framework (CycleGAN) to synthesize CT images from CBCT images. This model is capable of image-to-image translation using unpaired CT and CBCT images in an unsupervised learning setting. The sCT images generated from CBCT through this CycleGAN model are visually and quantitatively similar to real CT images with decreased mean absolute error (MAE) from 69.29 HU to 29.85 HU for head-and-neck (H&N) cancer patients. The dose distributions calculated on the sCT by CycleGAN demonstrated a higher accuracy than those on CBCT in a 3D gamma index analysis with increased gamma index pass rate from 86.92% to 96.26% under 1 mm/1% criteria, when using the deformed planning CT image (dpCT) as the reference. We also compared the CycleGAN model with other unsupervised learning methods, including deep convolutional generative adversarial networks (DCGAN) and progressive growing of GANs (PGGAN), and demonstrated that CycleGAN outperformed the other two models. A phantom study has been conducted to compare sCT with dpCT, and the increase of structural similarity index from 0.91 to 0.93 shows that CycleGAN performed better than DIR in terms of preserving anatomical accuracy.

1 March 2020 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
CSChenyang Shen
Chenyang Shen
DNDan Nguyen
Dan Nguyen
ZZZhiguo Zhou
Zhiguo Zhou
SJSteve B Jiang
Steve B Jiang
BDBin Dong
Bin Dong
XJXun Jia
Xun Jia
As one of the most popular approaches in artificial intelligence, deep learning (DL) has attracted a lot of attention in the medical physics field over the past few years. The goals of this topical review article are twofold. First, we will provide an overview of the method to medical physics researchers interested in DL to help them start the endeavor. Second, we will give in-depth discussions on the DL technology to make researchers aware of its potential challenges and possible solutions. As such, we divide the article into two major parts. The first part introduces general concepts and principles of DL and summarizes major research resources, such as computational tools and databases. The second part discusses challenges faced by DL, present available methods to mitigate some of these challenges, as well as our recommendations.

29 May 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
CSChenyang Shen
Chenyang Shen
YGYesenia Gonzalez
Yesenia Gonzalez
PKPeter Klages
Peter Klages
NQNan Qin
Nan Qin
HJHyunuk Jung
Hyunuk Jung
XJXun Jia
Xun Jia
Inverse treatment planning in radiation therapy is formulated as solving optimization problems. The objective function and constraints consist of multiple terms designed for different clinical and practical considerations. Weighting factors of these terms are needed to define the optimization problem. While a treatment planning optimization engine can solve the optimization problem with given weights, adjusting the weights to yield a high-quality plan is typically performed by a human planner. Yet the weight-tuning task is labor intensive, time consuming, and it critically affects the final plan quality. An automatic weight-tuning approach is strongly desired. The procedure of weight adjustment to improve the plan quality is essentially a decision-making problem. Motivated by the tremendous success in deep learning for decision making with human-level intelligence, we propose a novel framework to adjust the weights in a human-like manner. This study used inverse treatment planning in high-dose-rate brachytherapy (HDRBT) for cervical cancer as an example. We developed a weight-tuning policy network (WTPN) that observes dose volume histograms of a plan and outputs an action to adjust organ weighting factors, similar to the behaviors of a human planner. We trained the WTPN via end-to-end deep reinforcement learning. Experience replay was performed with the epsilon greedy algorithm. After training was completed, we applied the trained WTPN to guide treatment planning of five testing patient cases. It was found that the trained WTPN successfully learnt the treatment planning goals and was able to guide the weight tuning process. On average, the quality score of plans generated under the WTPN’s guidance was improved by ~8.5% compared to the initial plan with arbitrarily set weights, and by 10.7% compared to the plans generated by human planners. To our knowledge, this was the first time that a tool was developed to adjust organ weights for the treatment planning optimization problem in a human-like fashion based on intelligence learnt from a training process, which was different from existing strategies based on pre-defined rules. The study demonstrated potential feasibility to develop intelligent treatment planning approaches via deep reinforcement learning.