Yusuke Kobayashi

Dr. Yusuke Kobayashi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2023 in Radiology Case Reports
Verified
Journal Article
Open access
YKYusuke Kobayashi
Yusuke Kobayashi
YSYoshifumi Sugawara
Yoshifumi Sugawara
HTHiroyuki Takahata
Hiroyuki Takahata
TSTeruhiko Shimizu
Teruhiko Shimizu
NTNorihiro Teramoto
Norihiro Teramoto
TNTakashi Ninomiya
Takashi Ninomiya
Benign notochordal cell tumor (BNCT) is a benign lesion derived from notochordal cells. Although it is relatively common in intraosseous lesion, pulmonary BNCT is extremely rare. We present a case of 54-year-old male with multiple pulmonary nodules, in which were considered to be metastatic chordomas initially. For 20 months follow-up without any therapy, most of the nodules had no remarkable change but some nodules showed cystic change. We consulted with pathologists specializing in chordoma and the final diagnosis of the nodules was considered as BNCT rather than chordoma. We herein report the case of multiple pulmonary BNCTs with cystic change, comparing with previous reports.

7 January 2026 in Tomography
Verified
Journal Article
Open access
PDF file
YKYusuke Kobayashi
Yusuke Kobayashi
YTYuki Tanabe
Yuki Tanabe
TMTomoro Morikawa
Tomoro Morikawa
KYKazuki Yoshida Kazuki Yoshida
Kazuki Yoshida Kazuki Yoshida
KOKentaro Ohara
Kentaro Ohara
TKTeruhito Kido
Teruhito Kido
Background/Objectives: Super-resolution deep-learning reconstruction (SR-DLR) is an advanced image reconstruction technique, but its effect on dynamic myocardial computed tomography perfusion (CTP) imaging has not been evaluated. This study aimed to examine the impact of SR-DLR on image quality and perfusion parameters in dynamic myocardial CTP. Methods: Thirty-five patients who underwent dynamic myocardial CTP for coronary artery disease assessment were retrospectively analyzed. Two CTP datasets were reconstructed using hybrid iterative reconstruction (HIR) and SR-DLR. Image quality was compared qualitatively and quantitatively, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge rise slope (ERS). Equivalence of CT-derived myocardial blood flow (CT-MBF) between two reconstructions was tested using a previously reported 15% equivalence margin. Intra-patient variability of CT-MBF was evaluated using the robust coefficient of variation (rCV). Results: In the qualitative assessment, SR-DLR had significantly higher scores in contrast (4.0 vs. 2.0) and sharpness (4.5 vs. 2.5) compared with HIR (p < 0.001), while contrast scores were similar. In the quantitative assessment, SR-DLR demonstrated significantly lower image noise (19.4 vs. 29.4 HU), and improved SNR (6.1 vs. 4.1), CNR (13.7 vs. 10.9), and ERS (171.0 vs. 135.1 HU/mm) (all p < 0.001). Mean global CT-MBF was comparable (3.15 ± 0.91 mL/g/min for HIR vs. 3.18 ± 0.97 mL/g/min for SR-DLR) and equivalence was confirmed (p = 0.022). SR-DLR significantly reduced rCV compared with HIR (36.0% vs. 41.0%, p < 0.001). Conclusions: SR-DLR enhances image quality in dynamic myocardial CTP while maintaining mean global CT-MBF and reducing intra-patient variability.