Kazuki Yoshida Kazuki Yoshida

Kazuki Yoshida Kazuki Yoshida


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2018 in Case Reports in Radiology
Verified
Journal Article
Open access
PDF file
KYKazuki Yoshida Kazuki Yoshida
Kazuki Yoshida Kazuki Yoshida
MMMasao Miyagawa
Masao Miyagawa
TKTeruhito Kido
Teruhito Kido
KIKana Ide
Kana Ide
YSYoshifumi Sano
Yoshifumi Sano
TMTeruhito Mochizuki
Teruhito Mochizuki
Birt-Hogg-Dubé syndrome (BHD) is a rare autosomal dominant disease characterized by skin fibrofolliculomas, pulmonary cysts, spontaneous pneumothoraces, and renal cancers. Oncocytomas are benign epithelial tumors that are also rare. Recently, there have been a few case reports of BHD with a parotid oncocytoma that appears to have a BHD phenotype. Here we document the eighth known case and describe the magnetic resonance imaging features of the parotid oncocytoma, which mimicked Warthin’s tumor. Radiologists should be aware of the association between these rare disorders.

1 May 2023 in Journal of Computer Assisted Tomography
Verified
Journal Article
Open access
KYKazuki Yoshida Kazuki Yoshida
Kazuki Yoshida Kazuki Yoshida
YTYuki Tanabe
Yuki Tanabe
HNHikaru Nishiyama
Hikaru Nishiyama
TMTakuya Matsuda
Takuya Matsuda
HTHidetaka Toritani
Hidetaka Toritani
TKTeruhito Kido
Teruhito Kido
Objectives: We evaluated the feasibility of using deep learning with a convolutional neural network for predicting bone mineral density (BMD) and bone microarchitecture from conventional computed tomography (CT) images acquired by multivendor scanners. Methods: We enrolled 402 patients who underwent noncontrast CT examinations, including L1–L4 vertebrae, and dual-energy x-ray absorptiometry (DXA) examination. Among these, 280 patients (3360 sagittal vertebral images), 70 patients (280 sagittal vertebral images), and 52 patients (208 sagittal vertebral images) were assigned to the training data set for deep learning model development, the validation, and the test data set, respectively. Bone mineral density and the trabecular bone score (TBS), an index of bone microarchitecture, were assessed by DXA. BMDDL and TBSDL were predicted by deep learning with a convolutional neural network (ResNet50). Pearson correlation tests assessed the correlation between BMDDL and BMD, and TBSDL and TBS. The diagnostic performance of BMDDL for osteopenia/osteoporosis and that of TBSDL for bone microarchitecture impairment were evaluated using receiver operating characteristic curve analysis. Results: BMDDL and BMD correlated strongly (r = 0.81, P < 0.01), whereas TBSDL and TBS correlated moderately (r = 0.54, P < 0.01). The sensitivity and specificity of BMDDL for identifying osteopenia or osteoporosis were 93% and 90%, and 100% and 94%, respectively. The sensitivity and specificity of TBSDL for identifying patients with bone microarchitecture impairment were 73% for all values. Conclusions: The BMDDL and TBSDL derived from conventional CT images could identify patients who should undergo DXA, which could be a gatekeeper tool for detecting latent osteoporosis/osteopenia or bone microarchitecture impairment.

1 June 2024 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
YAYusuke Akazawa
Yusuke Akazawa
THTakashi Higaki
Takashi Higaki
KKKosuke Kashiwagi
Kosuke Kashiwagi
TCToshiyuki Chisaka
Toshiyuki Chisaka
HTHidemi Takata
Hidemi Takata
OYOsamu Yamaguchi
Osamu Yamaguchi

25 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TKTakanori Kouchi
Takanori Kouchi
YTYuki Tanabe
Yuki Tanabe
TTTakumasa Takemoto
Takumasa Takemoto
KYKazuki Yoshida Kazuki Yoshida
Kazuki Yoshida Kazuki Yoshida
YYYuta Yamamoto
Yuta Yamamoto
TKTeruhito Kido
Teruhito Kido
We evaluated the feasibility of myocardial perfusion ratio to the aorta (MPR) in static computed tomography perfusion (CTP) for detecting myocardial perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). Twenty-five patients with suspected coronary artery disease who underwent dynamic CTP and SPECT were retrospectively evaluated. CTP images scanned at a sub-optimal phase for detecting myocardial perfusion abnormalities were selected from dynamic CTP images and used as static CTP images in the present study. The diagnostic accuracy of MPR derived from static CTP was compared to those of visual assessment and conventional quantitative parameters such as myocardial CT attenuation (HU) and transmural perfusion ratio (TPR). The area under the curve of MPR (0.84; 95% confidence interval [CI], 0.76–0.90) was significantly higher than those of myocardial CT attenuation (0.73; 95% CI, 0.65–0.79) and TPR (0.76; 95% CI, 0.67–0.83) (p < 0.05). Sensitivity and specificity were 67% (95% CI, 54–77%) and 90% (95% CI, 86–92%) for visual assessment, 51% (95% CI, 39–63%) and 86% (95% CI, 82–89%) for myocardial CT attenuation, 63% (95% CI, 51–74%) and 84% (95% CI, 80–88%) for TPR, and 78% (95% CI, 66–86%) and 84% (95% CI, 80–88%) for MPR, respectively. MPR showed higher diagnostic accuracy for detecting myocardial perfusion abnormality compared with myocardial CT attenuation and TPR.

2 August 2024 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
HTHidetaka Toritani
Hidetaka Toritani
KYKazuki Yoshida Kazuki Yoshida
Kazuki Yoshida Kazuki Yoshida
THTakaaki Hosokawa
Takaaki Hosokawa
YTYuki Tanabe
Yuki Tanabe
YYYuta Yamamoto
Yuta Yamamoto
TKTeruhito Kido
Teruhito Kido
Objectives: This study evaluated the feasibility of a model-based iterative reconstruction technique (MBIR) tuned for the myocardium on myocardial computed tomography late enhancement (CT-LE). Methods: Twenty-eight patients who underwent myocardial CT-LE and late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) within 1 year were retrospectively enrolled. Myocardial CT-LE was performed using a 320-row CT with low tube voltage (80 kVp). Myocardial CT-LE images were scanned 7 min after CT angiography (CTA) without additional contrast medium. All myocardial CT-LE images were reconstructed with hybrid iterative reconstruction (HIR), conventional MBIR (MBIR_cardiac), and new MBIR tuned for the myocardium (MBIR_myo). Qualitative (5-grade scale) scores and quantitative parameters (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) were assessed as image quality. The sensitivity, specificity, and accuracy of myocardial CT-LE were evaluated at the segment level using an American Heart Association (AHA) 16-segment model, with LGE-MRI as a reference standard. These results were compared among the different CT image reconstructions. Results: In 28 patients with 448 segments, 160 segments were diagnosed with positive by LGE-MRI. In the qualitative assessment of myocardial CT-LE, the mean image quality scores were 2.9 ± 1.2 for HIR, 3.0 ± 1.1 for MBIR_cardiac, and 4.0 ± 1.0 for MBIR_myo. MBIR_myo showed a significantly higher score than HIR (P < 0.001) and MBIR_cardiac (P = 0.018). In the quantitative image quality assessment of myocardial CT-LE, the median image SNR was 10.3 (9.1–11.1) for HIR, 10.8 (9.8–12.1) for MBIR_cardiac, and 16.8 (15.7–18.4) for MBIR_myo. The median image CNR was 3.7 (3.0–4.6) for HIR, 3.8 (3.2–5.1) for MBIR_cardiac, and 6.4 (5.0–7.7) for MBIR_myo. MBIR_myo significantly improved the SNR and CNR of CT-LE compared to HIR and MBIR_cardiac (P < 0.001). The sensitivity, specificity, and accuracy for the detection of myocardial CT-LE were 70%, 92%, and 84% for HIR; 71%, 92%, and 85% for MBIR_cardiac; and 84%, 92%, and 89% for MBIR_myo, respectively. MBIR_myo showed significantly higher image quality, sensitivity, and accuracy than the others (P < 0.05). Conclusions: MBIR tuned for myocardium improved image quality and diagnostic performance for myocardial CT-LE assessment.

7 January 2026 in Tomography
Verified
Journal Article
Open access
PDF file
YKYusuke Kobayashi
Yusuke Kobayashi
YTYuki Tanabe
Yuki Tanabe
TMTomoro Morikawa
Tomoro Morikawa
KYKazuki Yoshida Kazuki Yoshida
Kazuki Yoshida Kazuki Yoshida
KOKentaro Ohara
Kentaro Ohara
TKTeruhito Kido
Teruhito Kido
Background/Objectives: Super-resolution deep-learning reconstruction (SR-DLR) is an advanced image reconstruction technique, but its effect on dynamic myocardial computed tomography perfusion (CTP) imaging has not been evaluated. This study aimed to examine the impact of SR-DLR on image quality and perfusion parameters in dynamic myocardial CTP. Methods: Thirty-five patients who underwent dynamic myocardial CTP for coronary artery disease assessment were retrospectively analyzed. Two CTP datasets were reconstructed using hybrid iterative reconstruction (HIR) and SR-DLR. Image quality was compared qualitatively and quantitatively, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge rise slope (ERS). Equivalence of CT-derived myocardial blood flow (CT-MBF) between two reconstructions was tested using a previously reported 15% equivalence margin. Intra-patient variability of CT-MBF was evaluated using the robust coefficient of variation (rCV). Results: In the qualitative assessment, SR-DLR had significantly higher scores in contrast (4.0 vs. 2.0) and sharpness (4.5 vs. 2.5) compared with HIR (p < 0.001), while contrast scores were similar. In the quantitative assessment, SR-DLR demonstrated significantly lower image noise (19.4 vs. 29.4 HU), and improved SNR (6.1 vs. 4.1), CNR (13.7 vs. 10.9), and ERS (171.0 vs. 135.1 HU/mm) (all p < 0.001). Mean global CT-MBF was comparable (3.15 ± 0.91 mL/g/min for HIR vs. 3.18 ± 0.97 mL/g/min for SR-DLR) and equivalence was confirmed (p = 0.022). SR-DLR significantly reduced rCV compared with HIR (36.0% vs. 41.0%, p < 0.001). Conclusions: SR-DLR enhances image quality in dynamic myocardial CTP while maintaining mean global CT-MBF and reducing intra-patient variability.