Lucija Faj

Ms. Lucija Faj

Kinesiology, University of Osijek, Osijek, Osječko-Baranjska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2023 in Biomechanics
Verified
Journal Article
Open access
PDF file
NPNicolas Mathias Philipp
Nicolas Mathias Philipp
Dimitrije CabarkapaDimitrije Cabarkapa
Dimitrije Cabarkapa
KMKennedy M. Marten
Kennedy M. Marten
DCDamjana V. Cabarkapa
Damjana V. Cabarkapa
DMDragan M. Mirkov
Dragan M. Mirkov
AFAndrew Fry
Andrew Fry
Given the multidirectional nature of the sport, handball athletes must frequently perform high-intensity decelerations to avoid defenders, generate space, or perform directional changes. The aim of the present study was twofold: (i) to investigate different kinematic measures of horizontal deceleration performance by comparing the acceleration-deceleration assessment (ADA) with the 5-0-5 test and (ii) to investigate relationships between force-time characteristics derived from the countermovement vertical jump (CVJ) and measures of horizontal deceleration performance. Eleven female handball players competing in the first-tier professional league in Europe performed three CVJs while standing on a uni-axial force plate system sampling at 1000 Hz, followed by two ADAs (i.e., maximal-effort acceleration over a 10 m distance, followed by rapid deceleration) and 5-0-5 test trials. Tripod-mounted radar sampling at 47 Hz, placed 5 m behind the start line, was used to record horizontal velocity data. Each test was separated by a 5–7 min rest interval to minimize the influence of fatigue. No statistically significant differences were found in horizontal deceleration performance parameters between ADA and the 5-0-5 test. However, athletes with a higher CVJ height and reactive strength index-modified showed better performance in terms of horizontal deceleration measures such as maximal approach velocity and average and maximal deceleration. Overall, these results may be of interest to practitioners working with multidirectional sport athletes such as handball players as they provide critical insight for the selection of assessments and training strategies targeted toward optimizing on-court athlete performance.

11 December 2024 in Life
Verified
Journal Article
Open access
PDF file
JAJelena Aleksic
Jelena Aleksic
DMDavid Mesaroš
David Mesaroš
DKDmitry Kanevsky
Dmitry Kanevsky
Olivera M. KneževićOlivera M. Knežević
Olivera M. Knežević
Dimitrije CabarkapaDimitrije Cabarkapa
Dimitrije Cabarkapa
Dragan MirkovDragan Mirkov
Dragan Mirkov
The countermovement vertical jump (CMJ) is widely used in sports science and rehabilitation to assess lower body power. In controlled laboratory environments, a complex analysis of CMJ performance is usually carried out using motion capture or force plate systems, providing detailed insights into athlete’s movement mechanics. While these systems are highly accurate, they are often costly or limited to laboratory settings, making them impractical for widespread or field use. This study aimed to evaluate the accuracy of MMPose, a markerless 2D pose estimation framework, for CMJ analysis by comparing it with force plates. Twelve healthy participants performed five CMJs, with each jump trial simultaneously recorded using force plates and a smartphone camera. Vertical velocity profiles and key temporal variables, including jump phase durations, maximum jump height, vertical velocity, and take-off velocity, were analyzed and compared between the two systems. The statistical methods included a Bland–Altman analysis, correlation coefficients (r), and effect sizes, with consistency and systematic differences assessed using intraclass correlation coefficients (ICC) and paired samples t-tests. The results showed strong agreement (r = 0.992) between the markerless system and force plates, validating MMPose for CMJ analysis. The temporal variables also demonstrated high reliability (ICC > 0.9), with minimal systematic differences and negligible effect sizes for most variables. These findings suggest that the MMPose-based markerless system is a cost-effective and practical alternative for analyzing CMJ performance, particularly in field settings where force plates may be less accessible. This system holds potential for broader applications in sports performance and rehabilitation, enabling more scalable, data-driven movement assessments.

19 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LFLucija Faj
Lucija Faj
JAJelena Aleksic
Jelena Aleksic
Olivera M. KneževićOlivera M. Knežević
Olivera M. Knežević
Branislav BožovićBranislav Božović
Branislav Božović
HBHrvoje Brkić
Hrvoje Brkić
Dragan MirkovDragan Mirkov
Dragan Mirkov
Affordable high-frame-rate cameras and open-source software, such as Kinovea (ver. 2025.1.0), have expanded the potential for conducting kinematic assessments outside laboratory settings. This study examined the reliability and validity of Kinovea’s semi-automated linear kinematics tracking tool by comparing its outputs with those from a 3D marker-based motion capture system (Qualisys). Ten recreationally active male basketball players (x̄ ± SD: age 23.7 ± 1.7 years; height 183 ± 5 cm; body mass 76.8 ± 9.8 kg) performed three CMJ trials, simultaneously recorded using both systems. Reflective markers placed on the shoulder, hip, and knee were tracked in Kinovea by two raters with different levels of experience to extract core CMJ variables (total take-off time and maximum vertical displacement) and complementary variables (eccentric and propulsion duration, and minimum vertical displacement). Inter-rater reliability and concurrent validity were evaluated using intraclass correlation coefficients (ICCs), coefficients of variation (CV%), standard error of measurement (SEM), and Bland–Altman analysis. Results showed excellent inter-rater reliability (ICC = 0.73–0.99) across all markers, with the hip and knee demonstrating the highest consistency. Strong validity relative to Qualisys was observed for both raters (ICC = 0.68–0.99; r > 0.80), with small systematic biases primarily in temporal variables. Collectively, these findings demonstrate that Kinovea’s semi-automated 2D analysis yields reliable and valid CMJ measurements comparable to 3D motion capture, even for less experienced users. As a free and easily deployable tool, it offers a widely accessible alternative for field-based performance monitoring and applied biomechanics research where laboratory-grade equipment is not available.