Hrvoje Brkić

Prof. Hrvoje Brkić

biophysics and medical physics, Faculty of Medicine University of Osijek, Osijek, Osječko-Baranjska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2014 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Open access
ZVZvonimir Vrselja
Zvonimir Vrselja
HBHrvoje Brkić
Hrvoje Brkić
SMStefan Mrdenovic
Stefan Mrdenovic
RRRadivoje Radic
Radivoje Radic
GCGoran Curic
Goran Curic
Nearly 400 years ago, Thomas Willis described the arterial ring at the base of the brain (the circle of Willis, CW) and recognized it as a compensatory system in the case of arterial occlusion. This theory is still accepted. We present several arguments that via negativa should discard the compensatory theory. (1) Current theory is anthropocentric; it ignores other species and their analog structures. (2) Arterial pathologies are diseases of old age, appearing after gene propagation. (3) According to the current theory, evolution has foresight. (4) Its commonness among animals indicates that it is probably a convergent evolutionary structure. (5) It was observed that communicating arteries are too small for effective blood flow, and (6) missing or hypoplastic in the majority of the population. We infer that CW, under physiologic conditions, serves as a passive pressure dissipating system; without considerable blood flow, pressure is transferred from the high to low pressure end, the latter being another arterial component of CW. Pressure gradient exists because pulse wave and blood flow arrive into the skull through different cerebral arteries asynchronously, due to arterial tree asymmetry. Therefore, CW and its communicating arteries protect cerebral artery and blood–brain barrier from hemodynamic stress.

1 October 2016 in Radiation Measurements
Verified
Journal Article
Open access
HBHrvoje Brkić
Hrvoje Brkić
AIAna Ivković
Ana Ivković
MKMladen Kasabašić
Mladen Kasabašić
MSMarina Poje Sovilj
Marina Poje Sovilj
SJSlaven Jurković
Slaven Jurković
DFDario Faj
Dario Faj
At present, high energy electron linear accelerators (LINACs) producing photons with energies higher than 10 MeV have a wide use in radiotherapy (RT). However, in these beams fast neutrons could be generated, which results in undesired contamination of the therapeutic beams. These neutrons affect the shielding requirements in RT rooms and also increase the out-of-field radiation dose to patients. The neutron flux becomes even more important when high numbers of monitor units are used, as in the intensity modulated radiotherapy. Herein, to evaluate the exposure of patients and medical personnel, it is important to determine the full radiation field correctly. A model of the dual photon beam medical LINAC, Siemens ONCOR, used at the University Hospital Centre of Osijek was built using the MCNP611 code. We tuned the model according to measured photon percentage depth dose curves and profiles. Only 18 MV photon beams were modeled. The dependence of neutron dose equivalent and energy spectrum on field size and off-axis distance in the patient plane was analyzed. The neutron source strength (Q) defined as a number of neutrons coming from the head of the treatment unit per x-ray dose (Gy) delivered at the isocenter was calculated and found to be 1.12 × 1012 neutrons per photon Gy at isocenter. The simulation showed that the neutron flux increases with increasing field size but field size has almost no effect on the shape of neutron dose profiles. The calculated neutron dose equivalent of different field sizes was between 1 and 3 mSv per photon Gy at isocenter. The mean energy changed from 0.21 MeV to 0.63 MeV with collimator opening from 0 × 0 cm2 to 40 × 40 cm2. At the 50 cm off-axis the change was less pronounced. According to the results, it is reasonable to conclude that the neutron dose equivalent to the patient is proportional to the photon beam-on time as suggested before. Since the beam-on time is much higher when advanced radiotherapy techniques are used to fulfill high conformity demands, this makes the neutron flux determination even more important. We also showed that the neutron energy in the patient plane significantly changes with field size. This can introduce significant uncertainty in dosimetry of neutrons due to strong dependence of the neutron detector response on the neutron energy in the interval 0.1–5 MeV

5 July 2019 in Journal of Chemical Information and Modeling
Verified
Journal Article
Closed access
Antonija TomićAntonija Tomić
Antonija Tomić
Gordan HorvatGordan Horvat
Gordan Horvat
MRMichael Ramek
Michael Ramek
DADejan Agić
Dejan Agić
HBHrvoje Brkić
Hrvoje Brkić
STSanja Tomić
Sanja Tomić

1 March 2019 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
AKAmir Hossein Karimi
Amir Hossein Karimi
HBHrvoje Brkić
Hrvoje Brkić
Daryoush Shahbazi-GahroueiDaryoush Shahbazi-Gahrouei
Daryoush Shahbazi-Gahrouei
SHSomayeh Biparva Haghighi
Somayeh Biparva Haghighi
IJIraj Jabbari
Iraj Jabbari

27 December 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
VKVjekoslav Kopacin
Vjekoslav Kopacin
HBHrvoje Brkić
Hrvoje Brkić
AIAna Ivković
Ana Ivković
MKMladen Kasabašić
Mladen Kasabašić
ŽKŽeljka Knežević
Željka Knežević
DFDario Faj
Dario Faj
Background: Monte Carlo (MC) simulations or measurements in anthropomorphic phantoms are recommended for estimating fetal dose in pregnant patients in radiotherapy. Among the many existing phantoms, there is no commercially available physical phantom representing the entire pregnant woman.Purpose: In this study, the development of a low‐cost, physical pregnant female phantom was demonstrated using commercially available materials. This phantom is based on the previously published computational phantom.Methods: Three tissue substitution materials (soft tissue, lung and bone tissue substitution) were developed. To verify Tena's substitution tissue materials, their radiation properties were assessed and compared to ICRP and ICRU materials using MC simulations in MV radiotherapy beams. Validation of the physical phantom was performed by comparing fetal doses obtained by measurements in the phantom with fetal doses obtained by MC simulations in computational phantom, during an MV photon breast radiotherapy treatment.Results: Materials used for building Tena phantom are matched to ICRU materials using physical density, radiation absorption properties and effective atomic number. MC simulations showed that percentage depth doses of Tena and ICRU material comply within 5% for soft and lung tissue, up to 25 cm depth. In the bone tissue, the discrepancy is higher, but again within 5% up to the depth of 5 cm. When the phantom was used for fetal dose measurements in MV photon breast radiotherapy, measured fetal doses complied with fetal doses calculated using MC simulation within 15%.Conclusions: Physical anthropomorphic phantom of pregnant patient can be manufactured using commercial materials and with low expenses. The files needed for 3D printing are now freely available. This enables further studies and comparison of numerical and physical experiments in diagnostic radiology or radiotherapy.

26 February 2021 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
HRHans Rabus
Hans Rabus
JGJose-Maria Gomez-Ros
Jose-Maria Gomez-Ros
CVCarmen Villagrasa
Carmen Villagrasa
JEJonathan Eakins
Jonathan Eakins
TVTomas Vrba
Tomas Vrba
PFPaolo Ferrari
Paolo Ferrari
Working Group (WG) 6 ‘Computational Dosimetry’ of the European Radiation Dosimetry Group promotes good practice in the application of computational methods for radiation dosimetry in radiation protection and the medical use of ionising radiation. Its cross-sectional activities within the association cover a large range of current topics in radiation dosimetry, including more fundamental studies of radiation effects in complex systems. In addition, WG 6 also performs scientific research and development as well as knowledge transfer activities, such as training courses. Monte Carlo techniques, including the use of anthropomorphic and other numerical phantoms based on voxelised geometrical models, play a strong part in the activities pursued in WG 6. However, other aspects and techniques, such as neutron spectra unfolding, have an important role as well. A number of intercomparison exercises have been carried out in the past to provide information on the accuracy with which computational methods are applied and whether best practice is being followed. Within the exercises that are still ongoing, the focus has changed towards assessing the uncertainty that can be achieved with these computational methods. Furthermore, the future strategy of WG 6 also includes an extension of the scope toward experimental benchmark activities and evaluation of cross-sections and algorithms, with the vision of establishing a gold standard for Monte Carlo methods used in medical and radiobiological applications.