Llateral ligament is sufficient. We hypothesized that increasing sizes and subtypes of anteromedial facet fractures cause increasing instability and that isolated lateral collateral ligament repair without fracture fixation would restore elbow stability in the presence of small subtype-I fractures....
1 June 2013 in Journal of Shoulder and Elbow Surgery
Background: Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the x‐ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and density‐mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT equivalent density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common density‐modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented.Results: Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K2HPO4) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K2HPO4 and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or density‐modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics.Conclusions: This review assessed the current state of QCT‐based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models.
1 March 2005 in Journal of Shoulder and Elbow Surgery
E on glenohumeral joint motion and stability. Methods: Cadaveric shoulders (n = 8) were mounted on a biomechanical testing apparatus that applies simulated loads to the rotator cuff and the anterior, middle, and posterior heads of the deltoid muscle. Testing was performed with the shoulder intact, after creation of the Bankart lesion, and after repair of the Bankart lesion. In addition, testing was performed after Bankart repair with and without remplissage in shoulders with 15% and 30% Hill-Sachs defects. Shoulder motion and glenohumeral translation were recorded with an optical tracking system. Outcomes measured included stability (joint stiffness and defect engagement) and internal-external glenohumeral rotational motion in adduction and in 90° of composite shoulder abduction. Results: In specimens with a 15% Hill-Sachs defect, Bankart repair combined with remplissage resulted in a significant reduction in internal-external range of motion in adduction (15.1° ± 11.1°, p = 0.039), but not in abduction (7.7° ± 9.9, p = 0.38), compared with the intact condition. In specimens with a 30% Hill-Sachs defect, repair that included remplissage also significantly reduced internal-external range of motion in adduction (14.5° ± 11.3°, p = 0.049) but not in abduction (6.2° ± 9.3°, p = 0.60). In specimens with a 15% Hill-Sachs defect, addition of remplissage significantly increased joint stiffness compared with isolated Bankart repair (p = 0.038), with the stiffness trending toward surpassing the level in the intact condition (p = 0.060). In specimens with a 30% Hill-Sachs defect, addition of remplissage restored joint stiffness to approximately normal (p = 0.41 compared with the intact condition). All of the specimens with a 30% Hill-Sachs defect engaged and dislocated after Bankart repair alone. The addition of remplissage was effective in preventing engagement and dislocation in all specimens. None of the specimens with a 15% Hill-Sachs defect engaged or dislocated after Bankart repair. Conclusions: In this experimental model, addition of remplissage provided little additional benefit to a Bankart repair in specimens with a 15% Hill-Sachs defect, and it also reduced specific shoulder motions. However, Bankart repair alone was ineffective in preventing engagement and recurrent dislocation in specimens with a 30% Hill-Sachs defect. The addition of remplissage to the Bankart repair in these specimens prevented engagement and enhanced stability, although at the expense of some reduction in shoulder motion. Clinical Relevance: The remplissage procedure has substantial effects on shoulder stability and motion....