Nikolas K. Knowles

Dr. Nikolas K. Knowles


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
NKNikolas K. Knowles
Nikolas K. Knowles
JRJacob M. Reeves
Jacob M. Reeves
LFLouis Ferreira
Louis Ferreira
Background: Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the x‐ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and density‐mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT equivalent density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common density‐modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented.Results: Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K2HPO4) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K2HPO4 and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or density‐modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics.Conclusions: This review assessed the current state of QCT‐based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models.

1 September 2019 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
SRSumit Raniga
Sumit Raniga
NKNikolas K. Knowles
Nikolas K. Knowles
EWEmily West
Emily West
LFLouis Ferreira
Louis Ferreira
GAGeorge S. Athwal
George S. Athwal

1 April 2019 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
KWKilian Wegmann
Kilian Wegmann
NKNikolas K. Knowles
Nikolas K. Knowles
ELEmily E. Lalone
Emily E. Lalone
MHMichael Hackl
Michael Hackl
LMLars P. Müller
Lars P. Müller
GAGeorge S. Athwal
George S. Athwal

1 February 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
NKNikolas K. Knowles
Nikolas K. Knowles
GLG. Daniel G. Langohr
G. Daniel G. Langohr
MFMohammadreza Faieghi
Mohammadreza Faieghi
ANAndrew Nelson
Andrew Nelson
LFLouis Ferreira
Louis Ferreira

25 October 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
NKNikolas K. Knowles
Nikolas K. Knowles
KIKenneth Ip
Kenneth Ip
LFLouis Ferreira
Louis Ferreira

31 July 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
NKNikolas K. Knowles
Nikolas K. Knowles
NNNathan Neeteson
Nathan Neeteson
SBSteven Kyle Boyd
Steven Kyle Boyd
Image-based finite element (FE) modeling of bone is a non-invasive method to estimate bone stiffness and strength. High-resolution imaging data as input allows for inclusion of bone microarchitecture but results in large amounts of data unsuitable for traditional FE solvers. Bone-specific mesh-free solvers have been developed over the past 20 years to improve on memory efficiency in simulated bone loading applications. The objective of this study was to provide linear performance benchmarking for a bone-specific, mesh-free solver (FAIM) using µCT and HR-pQCT image data on Mac, Linux, and Windows operating systems using both single- and multi-thread CPU and GPU processing. The focus is on the linear gradient-descent solver using standardized uniaxial loading of bone models from µCT, and first- and second-generation HR-pQCT scans of the radius and tibia. Convergence, speedup, memory, and batch performance tests were completed using CPUs and GPUs on three laboratory-based systems with Windows, Linux, and Mac operating systems. Although varying by system and model size, time-per-iteration was as low as 0.03 s when an HR-pQCT-based radius model (6.45 million DOF) was solved with 3 GPUs. Strong scaling was achieved with GPU and CPU parallel processing, with strong parallel efficiencies when models were solved using 3 GPUs or ≤ 10 CPU threads. Errors in force, strain energy density, and Von Mises stress were as low as 0.1% when a convergence tolerance of 10-3 or smaller was used. The results of this study indicate that to maximize computational efficiency and minimize model solution times using FAIM software under the standardized tested conditions using µCT, XCT1 and XCT2 HR-pQCT image data, convergence tolerance set to 10-4, and 10 threads or 2 GPUs are sufficient for efficient solution times. Less strict convergence tolerances will improve solution times but will introduce more error in the outcome measures.