Dilsora O'tkir qizi Axmadova

Ms. Dilsora O'tkir qizi Axmadova


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
NQNigora Xakimovna Qutlimurotova
Nigora Xakimovna Qutlimurotova
DADilsora O'tkir qizi Axmadova
Dilsora O'tkir qizi Axmadova
DIDilnoza Ismailova
Dilnoza Ismailova
JTJasur Tursunqulov
Jasur Tursunqulov
RQRukhiya Qutlimurotova
Rukhiya Qutlimurotova
NANargiza Atakulova
Nargiza Atakulova
A simple and cost-effective graphite paste electrode modified with 5-(4-aminophenyl)-4-amino-1,2,4-triazole-3(2H)-thione was developed for the selective voltammetric determination of Cu(II) ions in environmental water samples. The N,S-donor ligand was incorporated into a graphite–polystyrene matrix without the use of nanomaterials, providing a reproducible and straightforward electrode fabrication route. Scanning electron microscopy revealed a rough, porous surface morphology with an enhanced electroactive surface area of 0.065 cm2, approximately twice the geometric area. Electrochemical impedance spectroscopy confirmed diffusion-controlled mass transport, while cyclic voltammetry indicated quasi-reversible behaviour of the Cu(II)/Cu(0) redox system with a linear dependence of peak current on the square root of the scan rate. Differential pulse voltammetry under optimised conditions (0.1 mol·L−1 H2SO4, pH 1.0–1.2) yielded a linear analytical response over the concentration range of 0.01–0.4 μmol·L−1 (R2 = 0.99507), with a limit of detection of 0.02 μmol·L−1 and a limit of quantification of 0.06 μmol·L−1—well below the WHO guideline for copper in drinking water. The sensing mechanism involves selective N,S-bidentate coordination of Cu(II) at the electrode surface, followed by electrochemical reduction, as supported by FT-IR spectroscopic evidence. The sensor demonstrated good selectivity toward Cu(II) in the presence of common interfering metal ions at up to 20-fold excess. The method was successfully validated against ICP-OES (recovery 99.8%, RSD < 0.33%) and confirmed by spike–recovery experiments (99.0–99.5%), confirming its practical applicability for trace-level environmental monitoring. The modified electrode retained approximately 93% of its initial response after 30 consecutive measurements and 91% after 14 days of storage, demonstrating good operational stability.