Robert Sitnik

Prof. Robert Sitnik

Institute of Micromechanics and Photonics, Mechatronics Faculty, Warsaw University of Technology, Św. A. Boboli 8, 520 room, 02-525 Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2002 in Optical Engineering
Verified
Journal Article
Closed access
Robert SitnikRobert Sitnik
Robert Sitnik
MKMalgorzata Kujawinska
Malgorzata Kujawinska
JWJerzy M. Woznicki
Jerzy M. Woznicki
We present a system for 3-D shape measurement in large volumes based on combined digital-fringe-Gray-code projection. With the help of a new calibration procedure, the system provides accurate results despite its crossed-axis configuration and unknown aberrations of the digital light projector and CCD camera. Also, the separate clouds of points captured from different directions are automatically merged into the main cloud. The system delivers results in the form of (x,y,z) coordinates of the object points with additional (R G,B) color information about their texture. Applicability of the system is proven by presenting sample results of measurements performed on complex objects. The uncertainty of the system was estimated at 10-4 of the measurement volume.

1 November 2017 in Expert Systems with Applications
Verified
Journal Article
Closed access
ŁMŁukasz Markiewicz
Łukasz Markiewicz
MWMarcin Witkowski
Marcin Witkowski
Robert SitnikRobert Sitnik
Robert Sitnik
EMElżbieta Mielicka
Elżbieta Mielicka

1 March 2011 in Measurement
Verified
Journal Article
Closed access
Jerzy A. SładekJerzy A. Sładek
Jerzy A. Sładek
PBPaweł M. Błaszczyk
Paweł M. Błaszczyk
MKMagdalena Kupiec
Magdalena Kupiec
Robert SitnikRobert Sitnik
Robert Sitnik

27 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
PLPaweł Liberadzki
Paweł Liberadzki
Marcin AdamczykMarcin Adamczyk
Marcin Adamczyk
MWMarcin Witkowski
Marcin Witkowski
Robert SitnikRobert Sitnik
Robert Sitnik
The existing methods for measuring the shape of the human body in motion are limited in their practical application owing to immaturity, complexity, and/or high price. Therefore, we propose a method based on structured light supported by multispectral separation to achieve multidirectional and parallel acquisition. Single-frame fringe projection is employed in this method for detailed geometry reconstruction. An extended phase unwrapping method adapted for measurement of the human body is also proposed. This method utilizes local fringe parameter information to identify the optimal unwrapping path for reconstruction. Subsequently, we present a prototype 4DBODY system with a working volume of 2.0 × 1.5 × 1.5 m3, a measurement uncertainty less than 0.5 mm and an average spatial resolution of 1.0 mm for three-dimensional (3D) points. The system consists of eight directional 3D scanners functioning synchronously with an acquisition frequency of 120 Hz. The efficacy of the proposed system is demonstrated by presenting the measurement results obtained for known geometrical objects moving at various speeds as well actual human movements.

1 September 2012 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
MKMaciej Karaszewski
Maciej Karaszewski
Robert SitnikRobert Sitnik
Robert Sitnik
EBE. Bunsch
E. Bunsch

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Wojciech Michał GlinkowskiWojciech Michał Glinkowski
Wojciech Michał Glinkowski
Robert SitnikRobert Sitnik
Robert Sitnik
MWMarcin Witkowski
Marcin Witkowski
HKHanna Kocoń
Hanna Kocoń
PBPawel Bolewicki
Pawel Bolewicki
AGAndrzej GórEcki
Andrzej GórEcki
We present an automatic method for assessment of pectus excavatum severity based on an optical 3-D markerless shape measurement. A four-directional measurement system based on a structured light projection method is built to capture the shape of the body surface of the patients. The system setup is described and typical measurement parameters are given. The automated data analysis path is explained. Their main steps are: normalization of trunk model orientation, cutting the model into slices, analysis of each slice shape, selecting the proper slice for the assessment of pectus excavatum of the patient, and calculating its shape parameter. We develop a new shape parameter (I3ds) that shows high correlation with the computed tomography (CT) Haller index widely used for assessment of pectus excavatum. Clinical results and the evaluation of developed indexes are presented.