Marcin Witkowski

Marcin Witkowski

Auto-generated profile, based on publicly available information

Marcin Witkowski

Warsaw University of Technology

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Expert Systems with Applications
Verified
Journal Article
Closed access
ŁMŁukasz Markiewicz
Łukasz Markiewicz
MWMarcin Witkowski
Marcin Witkowski
Robert SitnikRobert Sitnik
Robert Sitnik
EMElżbieta Mielicka
Elżbieta Mielicka

27 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
PLPaweł Liberadzki
Paweł Liberadzki
Marcin AdamczykMarcin Adamczyk
Marcin Adamczyk
MWMarcin Witkowski
Marcin Witkowski
Robert SitnikRobert Sitnik
Robert Sitnik
The existing methods for measuring the shape of the human body in motion are limited in their practical application owing to immaturity, complexity, and/or high price. Therefore, we propose a method based on structured light supported by multispectral separation to achieve multidirectional and parallel acquisition. Single-frame fringe projection is employed in this method for detailed geometry reconstruction. An extended phase unwrapping method adapted for measurement of the human body is also proposed. This method utilizes local fringe parameter information to identify the optimal unwrapping path for reconstruction. Subsequently, we present a prototype 4DBODY system with a working volume of 2.0 × 1.5 × 1.5 m3, a measurement uncertainty less than 0.5 mm and an average spatial resolution of 1.0 mm for three-dimensional (3D) points. The system consists of eight directional 3D scanners functioning synchronously with an acquisition frequency of 120 Hz. The efficacy of the proposed system is demonstrated by presenting the measurement results obtained for known geometrical objects moving at various speeds as well actual human movements.

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Wojciech Michał GlinkowskiWojciech Michał Glinkowski
Wojciech Michał Glinkowski
Robert SitnikRobert Sitnik
Robert Sitnik
MWMarcin Witkowski
Marcin Witkowski
HKHanna Kocoń
Hanna Kocoń
PBPawel Bolewicki
Pawel Bolewicki
AGAndrzej GórEcki
Andrzej GórEcki
We present an automatic method for assessment of pectus excavatum severity based on an optical 3-D markerless shape measurement. A four-directional measurement system based on a structured light projection method is built to capture the shape of the body surface of the patients. The system setup is described and typical measurement parameters are given. The automated data analysis path is explained. Their main steps are: normalization of trunk model orientation, cutting the model into slices, analysis of each slice shape, selecting the proper slice for the assessment of pectus excavatum of the patient, and calculating its shape parameter. We develop a new shape parameter (I3ds) that shows high correlation with the computed tomography (CT) Haller index widely used for assessment of pectus excavatum. Clinical results and the evaluation of developed indexes are presented.

1 January 2012 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
JMJakub Michoński
Jakub Michoński
Wojciech Michał GlinkowskiWojciech Michał Glinkowski
Wojciech Michał Glinkowski
MWMarcin Witkowski
Marcin Witkowski
Robert SitnikRobert Sitnik
Robert Sitnik
Faulty postures, scoliosis and sagittal plane deformities should be detected as early as possible to apply preventive and treatment measures against major clinical consequences. To support documentation of the severity of deformity and diminish x-ray exposures, several solutions utilizing analysis of back surface topography data were introduced. A novel approach to automatic recognition and localization of anatomical landmarks of the human back is presented that may provide more repeatable results and speed up the whole procedure. The algorithm was designed as a two-step process involving a statistical model built upon expert knowledge and analysis of three-dimensional back surface shape data. Voronoi diagram is used to connect mean geometric relations, which provide a first approximation of the positions, with surface curvature distribution, which further guides the recognition process and gives final locations of landmarks. Positions obtained using the developed algorithms are validated with respect to accuracy of manual landmark indication by experts. Preliminary validation proved that the landmarks were localized correctly, with accuracy depending mostly on the characteristics of a given structure. It was concluded that recognition should mainly take into account the shape of the back surface, putting as little emphasis on the statistical approximation as possible.

1 May 2013 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
JLJanusz Lenar
Janusz Lenar
MWMarcin Witkowski
Marcin Witkowski
VCVincenzo Carbone
Vincenzo Carbone
SKSjoerd Kolk
Sjoerd Kolk
Marcin AdamczykMarcin Adamczyk
Marcin Adamczyk
NVNico Verdonschot
Nico Verdonschot
We report on a structured light-scanning system, the OGX|4DSCANNER, capable of capturing the surface of a human body with 2 mm spatial resolution at a 60 Hz frame-rate. The performance of modeling the human lower body dynamics is evaluated by comparing the system with the current gold standard, i.e., the VICON system. The VICON system relies on the application of reflective markers on a person’s body and tracking their positions in three-dimensional space using multiple cameras [optical motion capture (OMC)]. For the purpose of validation of the 4DSCANNER, a set of “virtual” markers was extracted from the measured surface. A set of musculoskeletal models was built for three subjects based on the trajectories of real and virtual markers. Next, the corresponding models were compared in terms of joint angles, joint moments, and activity of a number of major lower body muscles. Analyses showed a good overall agreement of the modeling outcome. We conclude that the 4DSCANNER within its limitations has the potential to be used in clinical gait analysis instead of optical marker-based systems. The advantage of the 4DSCANNER over OMC solutions is that it does not burden patients with time-consuming marker application. This study demonstrates the versatility of this measurement technique.

5 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RGRadoslaw Gierwialo
Radoslaw Gierwialo
MWMarcin Witkowski
Marcin Witkowski
MKMaciej Kosieradzki
Maciej Kosieradzki
Wojciech LisikWojciech Lisik
Wojciech Lisik
ŁGŁukasz Groszkowski
Łukasz Groszkowski
Robert SitnikRobert Sitnik
Robert Sitnik
This paper presents a projection-based augmented-reality system (MARVIS) that supports the visualization of internal structures on the surface of a liver phantom. MARVIS is endowed with three key features: tracking of spatial relationship between the phantom and the operator’s head in real time, monoscopic projection of internal liver structures onto the phantom surface for 3D perception without additional head-mounted devices, and phantom internal electronic circuit to assess the accuracy of a syringe guidance system. An initial validation was carried out by 25 medical students (12 males and 13 females; mean age, 23.12 years; SD, 1.27 years) and 3 male surgeons (mean age, 43.66 years; SD, 7.57 years). The validation results show that the ratio of failed syringe insertions was reduced from 50% to 30% by adopting the MARVIS projection. The proposed system suitably enhances a surgeon’s spatial perception of a phantom internal structure.