Fikret Arı

Dr. Fikret Arı


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2020 in Small
Verified
Journal Article
Closed access
PDF file
HTHadiseh Taheri
Hadiseh Taheri
MUMehmet Altay UNAL
Mehmet Altay UNAL
MSMelike Sevim
Melike Sevim
CGCANSU GURCAN
CANSU GURCAN
OEOkan Ekim
Okan Ekim
AYAçelya Yilmazer
Açelya Yilmazer

4 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EGEvrim Gökçe
Evrim Gökçe
EGEmel Güneş
Emel Güneş
FAFikret Arı
Fikret Arı
SHSerhat Hayme
Serhat Hayme
ENErhan Nalçacı
Erhan Nalçacı
Previous research indicates that different exercise modes might create different effects on cognition and peripheral protein signals. This study aimed to compare the effects of long-term participation in an open and closed-skill exercise on cognitive functions and Brain-derived neurotrophic factor and Cathepsin B levels. 18 fencers, 18 swimmers, 18 sedentary controls between 18–25 years old participated in the study. Participants performed visuospatial working memory, verbal fluency and selective attention tasks. Blood samples were tested for Brain-derived neurotrophic factor and Cathepsin B using ELISA. The results showed that fencers performed superiorly on some part of visuospatial working memory, verbal fluency, and selective attention tasks than swimmers and sedentary controls. Athlete groups showed higher scores on some subtests of visuospatial working memory and selective attention tasks than sedentary controls. The basal serum Brain-derived neurotrophic factor level was not significant between the groups, but Cathepsin B was higher in fencers than swimmers and sedentary controls. The peripheric protein signal response to acute exercise was significantly higher in athletes, particularly in the open-skill group for Cathepsin B. Our research provided noteworthy results that more cognitively challenging exercise may provide more benefits for some aspects of cognition. Since our findings suggest that open-skill exercise improves specific types of executive-control functioning, this exercise mode might be included in training programs to support cognition and prevent cognitive impairment.

1 November 2018 in Optical Fiber Technology
Verified
Journal Article
Closed access
INIsa Navruz
Isa Navruz
FAFikret Arı
Fikret Arı
MBMustafa Bilsel
Mustafa Bilsel
ZAZinah A. Al-Mashhadani
Zinah A. Al-Mashhadani

1 March 2025 in International Soil and Water Conservation Research
Verified
Journal Article
Open access
FAFikret Arı
Fikret Arı
SSSelen Deviren Saygin
Selen Deviren Saygin
CTCagla Temiz
Cagla Temiz
SASefika Arslan
Sefika Arslan
MUMehmet Altay Unal
Mehmet Altay Unal
DFDennis C. Flanagan
Dennis C. Flanagan

11 May 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YDYilmaz Durna
Yilmaz Durna
FAFikret Arı
Fikret Arı
This study proposes a novel binocular pupil and gaze detection system utilizing a remote full high definition (full HD) camera and employing LabVIEW. LabVIEW is inherently parallel and has fewer time-consuming algorithms. Many eye tracker applications are monocular and use low resolution cameras due to real-time image processing difficulties. We utilized the computer’s direct access memory channel for rapid data transmission and processed full HD images with LabVIEW. Full HD images make easier determinations of center coordinates/sizes of pupil and corneal reflection. We modified the camera so that the camera sensor passed only infrared (IR) images. Glints were taken as reference points for region of interest (ROI) area selection of the eye region in the face image. A morphologic filter was applied for erosion of noise, and a weighted average technique was used for center detection. To test system accuracy with 11 participants, we produced a visual stimulus set up to analyze each eye’s movement. Nonlinear mapping function was utilized for gaze estimation. Pupil size, pupil position, glint position and gaze point coordinates were obtained with free natural head movements in our system. This system also works at 2046 × 1086 resolution at 40 frames per second. It is assumed that 280 frames per second for 640 × 480 pixel images is the case. Experimental results show that the average gaze detection error for 11 participants was 0.76° for the left eye, 0.89° for right eye and 0.83° for the mean of two eyes.

1 October 2019
Verified
Conference Paper
Closed access
NMNilgun Ozturk Mutlu
Nilgun Ozturk Mutlu
MAM. Cenk Akbostanci
M. Cenk Akbostanci
FAFikret Arı
Fikret Arı
FKF. Tugra Karaarslan
F. Tugra Karaarslan
In this study, a method for the detection of rigidity movement disorder, which is one of the common symptoms of Parkinson's Disease, was developed. The developed method is based on an electromechanical measuring device. With this method, parameters related to stiffness of the patient's wrist were obtained by the computerized analysis of the recorded measurement data and comparison was made with the stiffness score of the physician. The data were compared with the motor scores of the Unified Parkinson's Disease Assessment Scale (UPDRS) and the Hoehn-Yahr Staging Scale. The results showed that the motor UPDRS scores and the Hoehn-Yahr Staging scale were consistent. Furthermore, it was seen that the rigidity enhancing effect of the Froment maneuver can be distinguished by the established system. It was noted that the stiffness scores with Froment maneuver measurements made for the same patient were 1 point higher than the stiffness scores without Froment maneuver measurements. Also; As a result of the comparison made with the stiffness scoring performed by the physician, it was found that the stiffness data obtained were generally consistent with the physician scoring. However, according to the data obtained, some physician scoring deviations from normal were determined. As a result of these studies, a lower-upper limit was established for stiffness values evaluated between 0-4 points. Thus, an objective method that can be used to evaluate the sign of stiffness was proposed.