Yilmaz Durna

Dr. Yilmaz Durna

Bilkent University, Ankara, Turkey (Türkiye)

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Optics Letters
Verified
Journal Article
Closed access
HKHasan Kocer
Hasan Kocer
YDYilmaz Durna
Yilmaz Durna
HKHamza Kurt
Hamza Kurt
EOEkmel Ozbay
Ekmel Ozbay
Beam splitters are an indispensable part of optical measurements and applications. We propose a dynamic beam splitter incorporating all-dielectric metasurface in an elastic substrate under external mechanical stimulus of stretching. The optical behavior at 720 nm wavelength shows that it can be changed from a pure optical-diode-like behavior to a dynamic beam splitter. Although the structure is designed running at 720 nm, the design approach with appropriate materials can be used at any wavelength. Various cases, including wavelength and polarization dependencies, are thoroughly investigated to demonstrate the principles of operating conditions of two different regimes of the designed metasurface. (C) 2020 Optical Society of America

13 August 2020 in RSC Advances
Verified
Journal Article
Open access
PDF file
MÇM. Cihan Çakır
M. Cihan Çakır
HKHasan Kocer
Hasan Kocer
YDYilmaz Durna
Yilmaz Durna
DYDeniz Umut Yildirim
Deniz Umut Yildirim
AGAmir Ghobadi
Amir Ghobadi
EOEkmel Ozbay
Ekmel Ozbay
A universal hybrid modeling approach is developed to model VO 2 in transition, revealing dynamic behavior of metallic inclusions and grain shapes.

11 May 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YDYilmaz Durna
Yilmaz Durna
FAFikret Arı
Fikret Arı
This study proposes a novel binocular pupil and gaze detection system utilizing a remote full high definition (full HD) camera and employing LabVIEW. LabVIEW is inherently parallel and has fewer time-consuming algorithms. Many eye tracker applications are monocular and use low resolution cameras due to real-time image processing difficulties. We utilized the computer’s direct access memory channel for rapid data transmission and processed full HD images with LabVIEW. Full HD images make easier determinations of center coordinates/sizes of pupil and corneal reflection. We modified the camera so that the camera sensor passed only infrared (IR) images. Glints were taken as reference points for region of interest (ROI) area selection of the eye region in the face image. A morphologic filter was applied for erosion of noise, and a weighted average technique was used for center detection. To test system accuracy with 11 participants, we produced a visual stimulus set up to analyze each eye’s movement. Nonlinear mapping function was utilized for gaze estimation. Pupil size, pupil position, glint position and gaze point coordinates were obtained with free natural head movements in our system. This system also works at 2046 × 1086 resolution at 40 frames per second. It is assumed that 280 frames per second for 640 × 480 pixel images is the case. Experimental results show that the average gaze detection error for 11 participants was 0.76° for the left eye, 0.89° for right eye and 0.83° for the mean of two eyes.

7 April 2022 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
HKHasan Kocer
Hasan Kocer
YDYilmaz Durna
Yilmaz Durna
BGBurak Gunes
Burak Gunes
GTGizem Tendurus
Gizem Tendurus
BBBayram Butun
Bayram Butun
EOEkmel Ozbay
Ekmel Ozbay
Gallium nitride (GaN) high-electron-mobility transistor (HEMT) devices, which have wide application potential from power amplifiers to satellite, need to be thoroughly examined in terms of reliability in order to benefit the superior intrinsic properties of the device. The most critical parameter in the device reliability is the hotspot, or ${T}_{\text {max}}$ , which occurs somewhere on the subsurface and along the channel of the GaN HEMT, which is optically inaccessible due to optical path disability. Therefore, the ${T}_{\text {max}}$ value is underestimated in optical measurements, such as the thermographic IR and Raman methods. With 3-D electrothermal simulations, ${T}_{\text {max}}$ is obtained close to reality, but it requires a huge computation load and the complex modeling of semiconductor device physics. In 2-D or 3-D thermal simulations that do not use electrothermal simulations, since the self-heating is mostly modeled with a single heat source, neither the correct ${T}_{\text {max}}$ value is obtained nor the effect of bias conditions is considered. To address the aforementioned shortcomings, a hybrid method is demonstrated, which exploits the electrical measurements of GaN HEMT, which RF and reliability engineers often and easily do. It is demonstrated that ${T}_{\text {max}}$ can be determined quickly and close to the electrothermal simulations in a GaN HEMT device with a two-heat source method and finite element analysis (FEA) hybrid interaction with respect to various bias conditions. Moreover, the impact of the knee voltage is investigated with different knee-detection techniques. The proposed method provides GaN HEMT reliability engineers with an easy-to-implement alternative to reveal the hotspot location and the value.

23 February 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
YDYilmaz Durna
Yilmaz Durna
HKHasan Kocer
Hasan Kocer
YAYunus Erdem Aras
Yunus Erdem Aras
MSMahmut Can Soydan
Mahmut Can Soydan
BBBayram Butun
Bayram Butun
EOEkmel Ozbay
Ekmel Ozbay
High electron mobility transistors (HEMTs) based on gallium nitride (GaN) with a wide range of application potentials need to be rigorously examined for reliability to take advantage of their intrinsically extraordinary properties. The most vital parameter of the reliability, the hotspot, or Tmax, resides in the two-dimensional electron gas (2DEG) temperature profile inside the device where optical access is often restricted. The device surface temperature can be measured by widespread IR thermography with the limitation of diffraction-based IR transmission losses. However, Tmax on the sub-surface cannot be reached thermographically. Although finite element analysis (FEA)-based thermal simulations can easily reveal the 2DEG temperature profile, accuracy is tightly dependent on the realistic modeling of material/structure parameters. Because these parameters are rather sensitive to fabrication and processing, it is quite difficult to specify them accurately. To overcome these drawbacks, a method integrating both IR thermography and FEA thermal analysis is demonstrated on a fabricated high-power 40 × 360 μm packaged GaN HEMT as a proof-of-concept. Utilizing the simulation and measurement temperature profiles, a correlation algorithm is developed so that accuracy of the FEA thermal simulation is improved by calibrating the parameters specific to fabrication/process conditions by thermographic measurement. Then, it is quantitatively shown that the proposed method is able to find the 2DEG temperature profile and Tmax with an accuracy that best suits the intrinsic and extrinsic characteristics of the device under test. The method sheds light on GaN reliability engineering by providing a feasible and reliable alternative to realistically reveal hotspot information for device lifetime assessments.

20 December 2022 in IEEE Transactions on Device and Materials Reliability
Verified
Journal Article
Closed access
SZSalahuddin Zafar
Salahuddin Zafar
YDYilmaz Durna
Yilmaz Durna
HKHasan Kocer
Hasan Kocer
BABusra Cankaya Akoglu
Busra Cankaya Akoglu
YAYunus Erdem Aras
Yunus Erdem Aras
EOEkmel Ozbay
Ekmel Ozbay
This paper presents a method to reveal the channel temperature profile of high electron mobility transistors (HEMTs) in a multi-stage monolithic microwave integrated circuit (MMIC). The device used for this study is a two-stage X-band low-noise amplifier fabricated using 0.15 m GaN-on-SiC technology with 4x50 m and 4x75 m HEMTs at the first and the second stage, respectively. The surface temperature measured through infrared (IR) thermography has a diffraction-limited resolution. Moreover, it is impossible to measure sub-surface Tmax residing inside the two-dimensional electron gas of HEMT using IR thermographic measurements. Finite element analysis (FEA) thermal simulations are performed in this study to acquire the surface and sub-surface temperature profiles of the whole MMIC. IR measurements and FEA simulations are integrated through a correlation-based method verifying the accuracy of the FEA-based temperature profiles. This method leads to accurately finding the hotspots in the MMIC, thus revealing the Tmax of both stages. The correlation method using two filters approach to match the measurements and simulated temperature profiles of all the stages finds its application in MMICs’ high-temperature operating lifetime reliability tests.