Alois Foltran Müller

Dr. Alois Foltran Müller

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in Anatomia, Histologia, Embryologia
Verified
Journal Article
Closed access
JGJulia B. Guaraná
Julia B. Guaraná
GAGüneş Aytaç
Güneş Aytaç
AMAlois Foltran Müller
Alois Foltran Müller
JTJesse Thompson
Jesse Thompson
SFSilvio Henrique de Freitas
Silvio Henrique de Freitas
BFBruno Ferrante
Bruno Ferrante

19 April 2011 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
PDF file
WEWilfried Engelke
Wilfried Engelke
AMAlois Foltran Müller
Alois Foltran Müller
ODOscar A. Decco
Oscar A. Decco
MRMaría J. Rau
María J. Rau
ACAndrea C. Cura
Andrea C. Cura
MKMichael Knösel
Michael Knösel
The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement.

29 September 2021 in Anatomia, Histologia, Embryologia
Verified
Journal Article
Closed access
PDF file
JGJulia Belotto Guaraná
Julia Belotto Guaraná
AMAlois Foltran Müller
Alois Foltran Müller
RSRicardo F Strefezzi
Ricardo F Strefezzi
FOFabrício Singaretti Oliveira
Fabrício Singaretti Oliveira
LMLuciana Cristina Machado
Luciana Cristina Machado
SFSilvio Henrique de Freitas
Silvio Henrique de Freitas

1 January 2026 in Animal Reproduction
Verified
Journal Article
Open access
Diego Rodrigues GomesDiego Rodrigues Gomes
Diego Rodrigues Gomes
DSDIANA VILLA VERDE SALAZAR
DIANA VILLA VERDE SALAZAR
DRDenise Jaques Ramos
Denise Jaques Ramos
CSCamila Silveira Stanquini
Camila Silveira Stanquini
TDTamiris Disselli
Tamiris Disselli
MFMarcus Antônio Rossi Feliciano
Marcus Antônio Rossi Feliciano
This study aimed to evaluate the applicability of fetal heart rate variability (FHRvar%), umbilical artery resistivity index (RI-UmbArt), and maternal body temperature (Temp, °C) for predicting parturition in bitches. Fifteen bitches (1-6 years old) were included. Gestational age was estimated using fetal biometry (inner chorionic cavity or biparietal diameter), and during the last week of pregnancy the animals were evaluated twice daily until parturition. Data were retrospectively grouped according to the hours before parturition (HBP). The evaluated parameters were FHRvar% (measured over 5-10 minutes using pulsed Doppler abdominal ultrasonography), RI-UmbArt (assessed by triplex Doppler in three fetuses per session), and Temp (rectal thermometry). Data were statistically compared and correlated with HBP. FHRvar% showed a gradual increase (P = 0.010) beginning at 84 HBP, reaching a peak between 24 and 12 HBP, whereas Temp significantly decreased during the last 24 HBP (P < 0.001). Both FHRvar% and Temp were significantly correlated with HBP (P < 0.001); however, these correlations were weak (Pearson’s r = −0.338 and −0.491, respectively). RI-UmbArt showed no significant variation across HBP (P = 0.711). An FHRvar% > 31.5% predicted parturition within 24 hours with a sensitivity of 65% and a specificity of 67%, whereas a Temp < 37.5°C predicted parturition with 69.6% sensitivity and 77.8% specificity. In conclusion, although FHRvar% and maternal body temperature are influenced by the proximity of parturition, they may not be reliable predictors of parturition timing, while RI-UmbArt appears to remain unchanged close to delivery.

1 January 2021 in Acta Cirurgica Brasileira
Verified
Journal Article
Open access
SFSilvio Henrique de Freitas
Silvio Henrique de Freitas
AMAlois Foltran Müller
Alois Foltran Müller
TFThaís Ribeiro Fadel
Thaís Ribeiro Fadel
WBWellington Henrique Bessi
Wellington Henrique Bessi
RDRenata Gebara Sampaio Dória
Renata Gebara Sampaio Dória
CACarlos Eduardo Ambrosio
Carlos Eduardo Ambrosio
To analyze and compare the reactions at the interface between the composite, composed of fragmented heterologous mineralized bone matrix (MOMHF) and polymethylmethacrylate (PMMA), and the rabbit’s tibias, through macroscopic evaluation and scanning electron microscopy (SEM) in different periods. In this study, 12 New Zealand adult rabbits were used (E1: n = 3, E2: n = 3, E3: n = 3 and E4: n = 3). They had the right tibial defects filled with composite and were evaluated immediately after surgery and at 30, 60, 90, and 120 days. The composites were incorporated and integrated into the recipient beds in 100% of the cases, defined by the MOMHF osseointegration and the PMMA fibrointegration, with no sign of infection, migration, or rejection. The behavior of the composites in the recipient beds demonstrates that these biomaterials have the potential to be used in bone defect repairs, offering, thus, better quality of life to the orthopedic patient.

1 January 2025 in Ciência Rural
Verified
Journal Article
Open access
PDF file
AMAlois Foltran Müller
Alois Foltran Müller
SFSilvio Henrique de Freitas
Silvio Henrique de Freitas
RDRenata Gebara Sampaio Dória
Renata Gebara Sampaio Dória
JGJulia Belotto Guaraná
Julia Belotto Guaraná
FMFábio Mendonça
Fábio Mendonça
BMBruno Watanabe Minto
Bruno Watanabe Minto
The ulna, humerus, femur, tibia, and calcaneus fractures repair, which are under constant tension due to exerted forces by the muscle groups adhered thereto, play a key role in the clinical-surgical routine, both in veterinary and human medicine. Therefore, the need for repairing orthopedic procedures is clear. Among the treatment options, the interlocking nail confers rigid stabilization on diaphyseal fractures. It has mechanical advantages over other stabilization techniques, such as plates, compression cortical screws (lag effect), or tension band technique. It was proposed in this study to mechanically compare two fixation methods (interlocking micro-nail or tension band) for fractures under muscular tension. The flexion force was assessed in a universal test machine (EMIC, DL 10000N model), comparing the interlocking micro-nail (IMN) to the tension band (TB) fixation system. The IMN and TB test specimens systems (n=6) went into total failure when the mean maximum force reached 511.20N and 279.90N, and the mean relative stiffness reached 31.33N/mm and 20.97 N/mm, respectively. A significant difference between IMN and TB for the variables maximum strength and relative stiffness were reported (P < 0.01). We concluded that, through mechanical flexion tests, the IMN system has superior resistance compared to the TB system. Thus, the IMN system may be a better option for fixing fractures under muscular tension forces.