This paper presents the transfer of a microgrid converter from/to on-grid to/from off-grid when the converter is working in two different modes. In the first transfer presented method, the converter operates as a Current Source Inverter (CSI) when on-grid and as a Voltage Source Inverter (VSI) when off-grid. In the second transfer method, the converter is operated as a VSI both, when operated on-grid and off-grid. The two methods are implemented successfully in a real platform but the later offers some advantage.
Microgrid integration and fault protection in complex network scenarios is a coming challenge to be faced with new strategies and solutions. In this context of increasing complexity, this paper describes two specific overload control strategies for four-wire inverters integrated in low voltage four-wire alternating current (AC) microgrids. The control of grid-tied microgrid inverters has been widely studied in the past and mainly focused on the use of droop control, which hugely constrains the time response during grid-disconnected operation. Taking into account the previous knowledge and experience about this subject, the main contribution of these two proposals regards providing fault current limitation in both operation modes, over-load capability skills in grid-connected operation and sinusoidal short-circuit proof in grid-disconnected operation. In the complex operation scenarios mentioned above, a hybrid combination of AC droop control based on dynamic phasors with varying virtual resistance, and voltage/frequency master voltage control for grid-(dis)connected operation modes are adopted as the mechanism to enhance time response. The two proposals described in the present document are validated by means of simulations using Matlab/Simulink and real experimental results obtained from CENER (The National Renewable Energy Centre) experimental ATENEA four-wire AC microgrid, obtaining time responses in the order of two-three grid cycles for all cases.
Anti-islanding detection methods have been part of a secure operation for distributed energy resource inverters, avoiding the creation of non-intentional energization when the mains are lost. These detection mechanisms were conceived historically for current-controlled inverters. New control possibilities have broken ground, and current- or voltage-controlled inverters are a reality; however, special attention must be paid to detection strategies when applied to the latter ones. This paper addresses two topics: it exposes the lack of effectiveness of those detection algorithms based on the voltage/frequency displacement concept under voltage-controlled inverters and evaluates the applicability limits of the others based on the impedance measurement (IM). The IM is presented as a valid mechanism to achieve the islanding detection, but the exploration of its limits drives the concept of detection frequency bandwidth (DFBW), introduced in this paper. The DFBW is suggested as a practical approach to select the proper injection frequency to measure. Therefore, an improved strategy based on the IM and DFBW is proposed to allow achieving the detection towards (non-)resonant loads considering low computational burden. The results were experimentally validated in a 90-kVA four-wire voltage-controlled inverter, offering detection times of less than 100 ms in any case.
This paper proposes a hybrid controller that combines conventional proportional-resonant controllers with the more recent application of fractional order calculus applied to the current control loop of voltage source converters. The use of existing non-integer orders applied to proportional-integral controllers is extended to resonant controllers. The application of fractional exponents for the integro-derivative parts contributes with an extra degree of freedom that permits to enhance the obtained response in an extended frequency range when the closed-loop bode diagram is analysed. Different implementation alternatives in the continuous time domain are presented, and the most suitable one is selected. The new controller formulation capabilities are compared with conventional proportional-resonant controllers via simulations and its performance is validated in a test platform based on a 20 kVA silicon-carbide converter acting as an active filter.
Isolated microgrids must be able to perform autonomous operation without external grid support. This leads to a challenge when non-dispatchable generators are installed because power imbalances can produce frequency excursions compromising the system operation. This paper addresses the optimal operation of PV–battery–diesel-based microgrids taking into account the frequency constraints. Particularly, a new stochastic optimization method to maximize the PV generation while ensuring the grid frequency limits is proposed. The optimization problem was formulated including a minimum frequency constraint, which was obtained from a dynamic study considering maximum load and photovoltaic power variations. Once the optimization problem was formulated, three complete days were simulated to verify the proper behavior. Finally, the system was validated in a laboratory-scaled microgrid.