Joao Luiz Carvalho

Dr. Joao Luiz Carvalho

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
VRVinicius Carvalho Rispoli
Vinicius Carvalho Rispoli
JNJon F. Nielsen
Jon F. Nielsen
Krishna NayakKrishna Nayak
Krishna Nayak
JCJoao Luiz Carvalho
Joao Luiz Carvalho
Phase contrast magnetic resonance imaging (PC-MRI) is used clinically for quantitative assessment of cardiovascular flow and function, as it is capable of providing directly-measured 3D velocity maps. Alternatively, vascular flow can be estimated from model-based computation fluid dynamics (CFD) calculations. CFD provides arbitrarily high resolution, but its accuracy hinges on model assumptions, while velocity fields measured with PC-MRI generally do not satisfy the equations of fluid dynamics, provide limited resolution, and suffer from partial volume effects. The purpose of this study is to develop a proof-of-concept numerical procedure for constructing a simulated flow field that is influenced by both direct PC-MRI measurements and a fluid physics model, thereby taking advantage of both the accuracy of PC-MRI and the high spatial resolution of CFD. The use of the proposed approach in regularizing 3D flow fields is evaluated. The proposed algorithm incorporates both a Newtonian fluid physics model and a linear PC-MRI signal model. The model equations are solved numerically using a modified CFD algorithm. The numerical solution corresponds to the optimal solution of a generalized Tikhonov regularization, which provides a flow field that satisfies the flow physics equations, while being close enough to the measured PC-MRI velocity profile. The feasibility of the proposed approach is demonstrated on data from the carotid bifurcation of one healthy volunteer, and also from a pulsatile carotid flow phantom. The proposed solver produces flow fields that are in better agreement with direct PC-MRI measurements than CFD alone, and converges faster, while closely satisfying the fluid dynamics equations. For the implementation that provided the best results, the signal-to-error ratio (with respect to the PC-MRI measurements) in the phantom experiment was 6.56 dB higher than that of conventional CFD; in the in vivo experiment, it was 2.15 dB higher. The proposed approach allows partial or complete measurements to be incorporated into a modified CFD solver, for improving the accuracy of the resulting flow fields estimates. This can be used for reducing scan time, increasing the spatial resolution, and/or denoising the PC-MRI measurements.

17 September 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
FSFabiano Araujo Soares
Fabiano Araujo Soares
JCJoao Luiz Carvalho
Joao Luiz Carvalho
CMCristiano Jacques Miosso
Cristiano Jacques Miosso
MAMarcelino Monteiro de Andrade
Marcelino Monteiro de Andrade
ARAdson Ferreira da Rocha
Adson Ferreira da Rocha
In surface electromyography (surface EMG, or S-EMG), conduction velocity (CV) refers to the velocity at which the motor unit action potentials (MUAPs) propagate along the muscle fibers, during contractions. The CV is related to the type and diameter of the muscle fibers, ion concentration, pH, and firing rate of the motor units (MUs). The CV can be used in the evaluation of contractile properties of MUs, and of muscle fatigue. The most popular methods for CV estimation are those based on maximum likelihood estimation (MLE). This work proposes an algorithm for estimating CV from S-EMG signals, using digital image processing techniques. The proposed approach is demonstrated and evaluated, using both simulated and experimentally-acquired multichannel S-EMG signals. We show that the proposed algorithm is as precise and accurate as the MLE method in typical conditions of noise and CV. The proposed method is not susceptible to errors associated with MUAP propagation direction or inadequate initialization parameters, which are common with the MLE algorithm. Image processing -based approaches may be useful in S-EMG analysis to extract different physiological parameters from multichannel S-EMG signals. Other new methods based on image processing could also be developed to help solving other tasks in EMG analysis, such as estimation of the CV for individual MUs, localization and tracking of innervation zones, and study of MU recruitment strategies.

14 March 2018
Verified
Book Chapter
Open access
PDF file
VRVinicius Carvalho Rispoli
Vinicius Carvalho Rispoli
JCJoao Luiz Carvalho
Joao Luiz Carvalho
CMCristiano J. Miosso
Cristiano J. Miosso
FSFabiano A. Soares
Fabiano A. Soares
Fourier velocity encoding (FVE) is an alternative to phase contrast imaging (PC). FVE provides considerably higher SNR than PC, due to its higher dimensionality and larger voxel sizes. Furthermore, FVE is robust to partial voluming, as it resolves the velocity distribution within each voxel. FVE data are usually acquired with low spatial resolution, due to scan-time restrictions associated with its higher dimensionality. FVE is capable of providing the velocity distribution associated with a large voxel, but does not directly provides a velocity map. Knowing the velocity distribution on a voxel is important for accurate diagnosis of stenosis in vessels on the scale of spatial resolution. Velocity maps, however, are useful for visualizing the actual blood flow through a vessel and can be used in different studies and diagnosis. In this context, this chapter deals with two aspects of the FVE MRI technique: acceleration and estimation of velocity map. First, are introduced six different acceleration techniques that can be applied to FVE acquisition. Methods such as variable-density sampling and compressive sampling. Then, is proposed a novel method to estimate velocity maps with high spatial resolution from low-resolution FVE data. Finally, it can be concluded that FVE datasets can be acquired in time scale comparable to PC, it contains more velocity information, since it resolves a velocity distribution within a voxel, and also provides an accurate estimation of the velocity map.