Nijanth Kothandapani

Mr. Nijanth Kothandapani


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
DSDan Robert Smith
Dan Robert Smith
SRScott Rand
Scott Rand
PHPeter Hruby
Peter Hruby
BFBen De Fresart
Ben De Fresart
Paul SubzakPaul Subzak
Paul Subzak
GTGovindasamy Tamizhmani
Govindasamy Tamizhmani
The 2025 International Technology Roadmap for Photovoltaics (ITRPV) projects that bifacial modules will dominate the photovoltaic (PV) market, reaching roughly 60–80% global share between 2024 and 2035, while monofacial PV modules will steadily decline. Current industry practice is to route the cable bundles along structural members such as main beams or torque tubes, thereby preventing rear-side shading but resulting in two key drawbacks: increased cable length and decreased system reliability due to cable proximity with rotating members and pinch points. Both effects contribute to higher system costs and reduced cable reliability. An alternative method involves suspending cable bundles directly behind the modules using hangers. While this approach mitigates excess length and risk of cable snags, it introduces the possibility of partial rear-side shading, which could possibly cause performance loss and hot-spot formation due to shade-induced electrical mismatch. Experimental evidence indicates that this risk is minimal, as albedo irradiance typically represents only 10–30% of front-side irradiance as reported in the literature and is largely diffuse, thereby limiting the likelihood of significant directional shading. This study evaluates the performance and reliability impacts of hanger-supported cable bundles under varying experimental conditions. Performance metrics assessed include maximum power output (Pmax), short-circuit current (Isc), open-circuit voltage (Voc), and fill factor (FF), while hot-spot risk was evaluated through measurements of module temperature uniformity using infrared imaging. Each cable (1X) was 6 AWG with a total outer diameter of approximately 9 mm. Experiments covered different cable bundle counts/sizes (2X, 6X, 16X), mounting configurations (fixed-tilt and single-axis tracker), and albedo conditions (snow-covered and snow-free ground). Measurements were conducted hourly on clear days between 8:00 and 16:00 from June to September 2025. The results consistently show that hanger-supported cable bundles have a negligible shading impact across all hours of the day and throughout the measurement period. This indicates that rear-side cable shading can be safely and practically disregarded in performance modeling and energy-yield assessments for the tested configurations, including fixed-tilt systems and single-axis trackers with or without torque tube shading and with various hanger sizes and cable-bundle counts. Therefore, hanging cables behind modules is a cost- and reliability-friendly, safe and recommended practice.

5 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AKAkash Kumar
Akash Kumar
NKNijanth Kothandapani
Nijanth Kothandapani
STSai Tatapudi
Sai Tatapudi
SBSagar Bhoite
Sagar Bhoite
GTGovindasamy Tamizhmani
Govindasamy Tamizhmani
This study investigates the influence of array height, irradiance, and wind speed on temperature difference and thermal gradients in photovoltaic (PV) arrays operating in hot, arid conditions. A field experiment was conducted in Mesa, Arizona (latitude 33° N), using two fixed-tilt PV module arrays installed at different elevations—one at 1 m and the other at 2 m above ground level. Each array comprised seven monocrystalline PV modules arranged in a single row with an 18° tilt angle optimized for summer performance. Data were collected between June and September 2025 and the analysis was restricted to 10:00–13:00 h to avoid shading and ensure uniform irradiance exposure on both arrays. Measurements included module backsheet temperatures at the center and edge modules, ambient temperature, plane-of-array (POA) irradiance, and wind speed. By maintaining identical orientation, tilt, and exposure conditions, the evaluation isolated the effect of height on module operating temperature and intra-array thermal gradients. Results indicate that the 2 m array consistently operated 1–3°C cooler than the 1 m array, confirming the positive impact of elevation on convective cooling. This reduction corresponds to a 0.4–0.9 % improvement in module efficiency or power based on standard temperature coefficients of crystalline silicon modules. The 1 m array exhibited a mean edge–center temperature gradience of −1.54°C, while the 2 m array showed −2.47°C, indicating stronger edge cooling in the elevated configuration. The 1 m array displayed a broader temperature range (−7 °C to +3°C) compared to the 2 m array (−5°C to +2°C), reflecting greater variability and weaker convective uniformity near ground level. The temperature gradience became more negative as irradiance increased, signifying intensified edge cooling under higher solar loading. Conversely, wind speed inversely affected ΔT, mitigating thermal gradients at higher airflow velocities. Overall, elevating PV arrays enhances convective heat transfer, reduces module temperature, and improves reliability and power output. These findings highlight the importance of array height, array length, irradiance, and wind conditions in optimizing PV system thermal and electrical performance.

25 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
AKAkash Kumar
Akash Kumar
NKNijanth Kothandapani
Nijanth Kothandapani
STSai Tatapudi
Sai Tatapudi
SBSagar Bhoite
Sagar Bhoite
GTGovindasamy Tamizhmani
Govindasamy Tamizhmani
This study investigates the influence of array height, irradiance, and wind speed on temperature difference and thermal gradients in photovoltaic (PV) arrays operating in hot, arid conditions. A field experiment was conducted in Mesa, Arizona (latitude 33° N), using two fixed-tilt PV module arrays installed at different elevations—one at 1 m and the other at 2 m above ground level. Each array comprised seven monocrystalline PV modules arranged in a single row with an 18° tilt angle optimized for summer performance. Data were collected between June and September 2025, and the analysis was restricted to 10:00–13:00 h to avoid shading and ensure uniform irradiance exposure on both arrays. Measurements included module backsheet temperatures at the center and edge modules, ambient temperature, plane-of-array (POA) irradiance, and wind speed. By maintaining identical orientation, tilt, and exposure conditions across all PV configurations, the influence of array height was isolated by comparing module operating temperatures between the 1-m and 2-m installations (inter-array comparison). Under the same controlled conditions, the setup also enabled an examination of how the intra-array comparison affects temperature gradients along the PV modules themselves, thereby revealing edge-center thermal non-uniformities. Results indicate that the 2 m array consistently operated 1–3 °C cooler than the 1 m array, confirming the positive impact of elevation on convective cooling. This reduction corresponds to a 0.4–0.9% improvement in module efficiency or power based on standard temperature coefficients of crystalline silicon modules. The 1 m array exhibited a mean edge–center intra-array temperature gradient of −1.54 °C, while the 2 m array showed −2.47 °C, indicating stronger edge cooling in the elevated configuration. The 1 m array displayed a broader temperature range (−7 °C to +3 °C) compared to the 2 m array (−5 °C to +2 °C), reflecting greater variability and weaker convective uniformity near ground level. The intra-array temperature gradient became more negative as irradiance increased, signifying intensified edge cooling under higher solar loading. Conversely, wind speed inversely affected ΔT, mitigating thermal gradients at higher airflow velocities. These findings highlight the importance of array height (inter-array), string length (intra-array), irradiance, and wind conditions in optimizing PV system thermal and electrical performance.