As society ages, wireless body area networks (WBANs) are expected to increasingly improve the quality of life of the elderly and disabled. One promising WBAN technology is human body communication (HBC), which utilizes part of the human body as a transmission medium. Communication between head-mounted wearable devices, such as hearing aids, is a potential HBC application. To clarify the HBC transmission mechanism between head-mounted wearable devices, this study analyzes the input impedance characteristics of the transceiver electrodes, transmission characteristics, and electric field distributions around and through a detailed head model. The investigation was performed via an electromagnetic field simulation. The signal frequency had less effect on the transmission characteristics and electric field distributions at 10, 20, and 30 MHz. However, the transmission mechanism between the head-mounted wearable devices was influenced by the number of electrodes in the transceiver. Moreover, the transmission characteristics between two-electrode transceivers were improved by impedance matching. Finally, the availability of the proposed system was evaluated from power consumption and human safety perspectives.
Daily and continuous measurement of glycemia is vital for managing diabetes. To improve a patient's quality of life, we propose non-invasive glycemia monitoring based on bioimpedance. This study aims to investigate the optimal frequency band for bioimpedance-measurement to estimate the blood-glucose level. We clarify the frequency characteristics of the correlation coefficient between blood-glucose level and bioimpedance from the subject experiment. It is found that the frequency band below 40 kHz is a candidate for stable estimation.
Implantable medical devices, such as neurostimulators, need to be wirelessly controlled from outside the body. Many of these devices use high-frequency signals in the 400 MHz, 900 MHz, and 2.45 GHz bands to communicate with external devices. However, high-frequency bands can suffer from signal attenuation in biological tissues and from electromagnetic interference with surrounding devices. In contrast, human body communication (HBC) uses relatively low frequencies in the 3–30 MHz band, which can alleviate signal attenuation and prevent emissions outside the body during communication. In this study, we investigated the use of HBC for implantable medical devices in the abdomen using electromagnetic field simulations. The results showed that the transmission between the transmitter inside the body and the receiver outside the body was adequate for stable communication. However, when the receiver was detached from the skin surface, the transmission characteristics rapidly decreased. Moreover, when the receiver and skin were separated by 1 mm, the transmission degraded by 34 dB, indicating that electromagnetic interference between the implanted transmitter and surrounding devices (including other medical devices) is rare. Finally, we evaluated the proposed system from the perspective of medical electromagnetic compatibility and human safety. The simulation results demonstrated that the radiated emissions and human exposure of the HBC system meet international standards.
Human body communication (HBC) is a wireless communication method that uses the human body as part of the transmission medium. Electrodes are used instead of antennas, and the signal is transmitted by the electric current through the human body and by the capacitive coupling outside the human body. In this study, direction of electric field lines and direction of electric current through the human body were analyzed by the finite-difference time-domain method to clarify the signal path, which is not readily apparent from electric field strength distribution. Signal transmission from a transmitter on the subject’s wrist to an off-body receiver touched by the subject was analyzed for two types of transmitter electrode settings. When both the signal and ground electrodes were put in contact with the human body, the major return path consisted of capacitive coupling between the receiver ground and the human body, and the electric current through the human body that flowed back to the ground electrode of the transmitter. When the ground electrode was floating, the only return path was through the capacitive coupling of the floating ground. These results contribute to the better understanding of signal transmission mechanism of HBC and will be useful for developing HBC applications.
In human body communication (HBC) systems, radio-frequency signals are excited in the human body through a wearable antenna comprised of electrodes that are in contact with the surface of the body. The input impedance characteristics of these antennas are important design parameters for increasing transmission efficiency and reducing signal reflection, similar to other wireless circuits. In this study, we discuss variations of input impedance characteristics of a wearable antenna prototype caused by differences among real human subjects. A realistic human arm model is used for simulations, and the analytical results obtained are compared to measured data obtained from real human subjects, in a range from 1 to 100 MHz. The simulations of input impedance characteristics from antennas worn on the wrists of male and female models with dry and wet skin conditions show that the impedance variation between genders is small. The moisture condition of the skin has little influence on frequencies exceeding several MHz. Measurements with a proto-type wearable antenna and 22 real human subjects reveal that HBC is robust against the variations of individual users from the viewpoint of the voltage standing wave ratio. Moreover, a simplified rectangular prism model is proposed to analyze the thickness of body tissues. Comparisons of measured input impedances indicate that individual differences in impedance are mainly due to differences in the thickness of skin and fat layers. The model also enables us to design the antenna prototype without multiple subject experiments.
Daily monitoring of blood glucose levels is vital for managing diabetes; however, invasive blood sampling is a burden on patients. To improve patients’ quality of life, bioimpedance-based noninvasive blood glucose monitoring (BI-NIBGM) that involves wearable electrodes on the wrist has been proposed. In this study, we investigated the validity of applying a simple NaCl solution to a blood phantom for in vitro evaluation of BI-NIBGM. The electrical properties of cow blood and various blood phantoms with different NaCl concentrations were measured based on the parallel-plate method at frequencies from 200 kHz to 100 MHz. The following observations were made: (1) the conductivity of blood can be mimicked accurately with simple NaCl solutions, and the optimal concentration of the phantom depends on the operating frequency and (2) it is challenging to mimic the relative permittivity of blood with simple NaCl solutions because NaCl lacks a cellular structure. Furthermore, the relationship between the bioimpedance and electrical properties of the phantom was examined using a simplified arm model. The results indicate that the relative permittivity of the blood layer has little effect on the bioimpedance and that only the conductivity determines the bioimpedance. Therefore, the NaCl concentration of the phantom can be adjusted from the viewpoint of conductivity for BI-NIBGM.