Javad Sajedifar

Javad Sajedifar


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Science of The Total Environment
Verified
Journal Article
Closed access
GGGholamreza Goudarzi
Gholamreza Goudarzi
MSMohammad Shirmardi
Mohammad Shirmardi
ANAbolfazl Naimabadi
Abolfazl Naimabadi
AGAta Ghadiri
Ata Ghadiri
JSJavad Sajedifar
Javad Sajedifar

1 July 2019 in Safety Science
Verified
Journal Article
Closed access
AMAhmad Mehri
Ahmad Mehri
JSJavad Sajedifar
Javad Sajedifar
MAMilad Abbasi
Milad Abbasi
ANAbolfazl Naimabadi
Abolfazl Naimabadi
AMAli Akbar Mohammadi
Ali Akbar Mohammadi
SZSeyed Abolfazl Zakerian
Seyed Abolfazl Zakerian

1 January 2018 in Industrial Health
Verified
Journal Article
Open access
JSJavad Sajedifar
Javad Sajedifar
AKAmir Hossein Kokabi
Amir Hossein Kokabi
SDSomayeh Farhang Dehghan
Somayeh Farhang Dehghan
AMAhmad Mehri
Ahmad Mehri
KAKamal Azam
Kamal Azam
FGFarideh Golbabaei
Farideh Golbabaei
Electric arc welding is a routine operation in the construction of metallic structures, but the fumes generated during the welding process can threaten the health of welders. Fumes are undesirable products of the majority of welding operations and may have various detrimental effects on health. The purpose of this study was to investigate the effect of operational parameters of the shielded metal arc welding (SMAW) process on the emission of fumes. A dust monitor was used to measure the number and mass concentration of fumes generated by SMAW. Measurements were made at the distances of 23 cm (hood inlet) and 41 cm (welder's breathing zone) from the weld point, with different values assigned to three operational parameters, namely current intensity, travel speed, and heat input (HI). Number concentration (NC) decreased with the increase in particle size. The highest mass concentrations (MC) were observed for MC1 (0.35-0.5 μm) and MC8 (Larger than 6.5 μm). For reducing exposures to fumes, welders are recommended to use the lowest voltage and amperage and the highest travel speed to the extent that does not compromise in the quality of welds. For assessment of exposure to airborne particles in industrial workplaces and specially in welding operations, it is thought that taking, solely, mass concentration in to consideration and lack of attention to number concentration would not be able to reflect accurate assessment of the adverse effects of particles on the body organs.

27 October 2018 in Health Promotion Perspectives
Verified
Journal Article
Open access
AMAhmad Mehri
Ahmad Mehri
SDSomayeh Farhang Dehghan
Somayeh Farhang Dehghan
MAMilad Abbasi
Milad Abbasi
MBMohammad Hosein Beheshti
Mohammad Hosein Beheshti
JSJavad Sajedifar
Javad Sajedifar
JSJafari Sm
Jafari Sm
Background: The purpose of this study was to assess the contrast perception of obstacles in a tunnel entrance which was placed in Ilam Province, Iran.Methods: An obstacle with the reflection coefficient of 20% was mounted at the entrance of thetunnel and then, the car was placed near the tunnel entrance and the intrinsic luminance of the road (Lr,intrinsic) and obstacle (Lo,intrinsic) were measured inside the car using the luminance meter.Results: Intrinsic luminance of obstacle and road at the entrance of the tunnel were measured as 41 and 17 cd/m2, respectively. The contrast perception of obstacle in deriver’s eyes and in the safe stopping distance (SSD) from the tunnel entrance was determined as 2.79 cd/m2. At the entrance of the studied tunnel, the contrast perception of obstacles with the reflection coefficient of 20% was lower than the minimum contrast perception (28%) recommended by International Commission on Illumination.Conclusion: The main conclusion that can be drawn from it, is that this obstacle in the SSD from the tunnel entrance cannot be conceived by the drivers, which may lead to higher rate of road traffic crashes.

30 July 2018 in Russian Open Medical Journal
Verified
Journal Article
Open access
AGAbdollah Gholami
Abdollah Gholami
JSJavad Sajedifar
Javad Sajedifar
BFbehzad fouladi
behzad fouladi
LGLeila Ibrahimi Gavamabadi
Leila Ibrahimi Gavamabadi
GTGholam Heidar Teimori
Gholam Heidar Teimori
MAMohsen Attar
Mohsen Attar
Introduction In the mineral industry, there are various operations such as extraction of mineral materials, crushing, screening, loading etc., which result in the exposure of workers to high concentrations of inhalable particulates. Exposure to inhalable dust can endanger the safety and health of workers [1]. Silica is the most abundant element in the earth’s crust, which is a toxic substance to the human respiratory system [2].

19 September 2024 in Heliyon
Verified
Journal Article
Open access
JSJavad Sajedifar
Javad Sajedifar
SMSeyyed Bagher Moetazavi
Seyyed Bagher Moetazavi
HMHassan Asilian Mahabadi
Hassan Asilian Mahabadi
In the present study, a novel fixed-bed continuous reactor with a preheating chamber was designed to be utilized for the practical application of removal studies of dangerous pollutants, especially NOX removal by NOX Storage Reduction (NSR) catalysts on a laboratory scale. The reactor's design and operational parameters, including outer wall temperature (50–600 °C), volumetric flow rate (0.3–3 L/min), wall temperature time (0.16–10 min), and granule surface area inside the preheating chamber (0–270 cm2), were statistically modeled and optimized using Response Surface Methodology (RSM). For more logical and effective parameter optimization, the ratio of gas and catalyst temperatures and pressure drop to the reactor outer wall temperature (GT/ROWT, CT/ROWT, and PD/ROWT) were also included in the optimization process. Experimental results showed that gas temperature, catalyst temperature, and pressure drop ranged from 31 to 177 °C, 51–585 °C, and 7–153 Pa, respectively. Optimal conditions were determined to be an outer wall temperature of 230 °C, a volumetric flow rate of 3 L/min, a wall temperature time of 0.16 min, and a granule surface area of 67.3 cm2. The results demonstrated that outer wall temperature, flow rate, time, and surface area of granules have significant and interaction effects on the responses and should be considered when researchers assess the removal efficiency of thermal catalysts.