Quantitative myocardial and blood T1 have recently achieved clinical utility in numerous pathologies, as they provide non-invasive tissue characterization with the potential to replace invasive biopsy. Native T1 time (no contrast agent), changes with myocardial extracellular water (edema, focal or diffuse fibrosis), fat, iron, and amyloid protein content. After contrast, the extracellular volume fraction (ECV) estimates the size of the extracellular space and identifies interstitial disease. Spatially resolved quantification of these biomarkers (so-called T1 mapping and ECV mapping) are steadily becoming diagnostic and prognostically useful tests for several heart muscle diseases, influencing clinical decision-making with a pending second consensus statement due mid-2017. This review outlines the physics involved in estimating T1 times and summarizes the disease-specific clinical and research impacts of T1 and ECV to date. We conclude by highlighting some of the remaining challenges such as their community-wide delivery, quality control, and standardization for clinical practice.
Purpose: To develop a novel pulse sequence for free‐breathing, multislice, native myocardial T1 mapping.Methods: The slice‐interleaved T1 (STONE) sequence consists of multiple sets of single‐shot images of different slices, acquired after a single nonselective inversion pulse. Each slice is only selectively excited once after each inversion pulse to allow sampling of the unperturbed longitudinal magnetization in the adjacent slices. For respiratory motion, a prospective slice‐tracking respiratory navigator is used to decrease through‐plane motion followed by a retrospective image registration to reduce in‐plane motion. STONE T1 maps were calculated using both a two‐parameter and three‐parameter fit model. The accuracy and precision of the STONE sequence for different T1, T2, and inversion pulse efficiency were studied using numerical simulations and phantom experiments. T1 maps from 14 subjects were acquired with the STONE sequence and T1s were compared to the MOdified Look‐Locker Inversion recovery sequence (MOLLI).Results: In numerical simulations and phantom experiments, the STONE sequence using a two‐parameter fit model yields more accurate T1 times compared to MOLLI, with similar high precision. The three‐parameter fit model further improves the accuracy, but with a reduced precision. The native myocardial T1 times were higher in the STONE sequence using two‐ or three‐parameter fit compared to MOLLI. The standard deviation of the T1 times was lower in the STONE T1 maps with a two‐parameter fit compared with MOLLI or a three‐parameter fit.Conclusion: The STONE sequence allows accurate and precise quantification of native myocardial T1 times with the additional benefit of covering the entire ventricle. Magn Reson Med 74:115–124, 2015.
Purpose: To develop an improved T2 prepared (T2prep) balanced steady‐state free‐precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T2 mapping.Methods: Myocardial T2 mapping is commonly performed by acquisition of multiple T2prep bSSFP images and estimating the voxel‐wise T2 values using a two‐parameter fit for relaxation. However, a two‐parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T2prep RF pulses, which may decrease the robustness of T2 mapping. Therefore, we propose a novel T2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T2prep echo time. This enables the robust estimation of T2 maps using a 3‐parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T2 maps generated using the proposed 3‐parameter model with the conventional two‐parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models.Results: Phantom and in vivo data show that the T2 values generated by the proposed 3‐parameter model fitting do not change with different choices of the T2prep echo times, and are not statistically different than the reference values for the phantom (P = 0.10 with three T2prep echoes). The two‐parameter model exhibits dependence on the choice of T2prep echo times and are significantly different than the reference values (P = 0.01 with three T2prep echoes).Conclusion: The proposed imaging sequence in combination with a three‐parameter model allows accurate measurement of myocardial T2 values, which is independent of number and duration of T2prep echo times. Magn Reson Med 74:93–105, 2015.