Objective: We aimed to investigate the association of diffuse myocardial fibrosis by cardiac magnetic resonance (CMR) T1 with complex ventricular arrhythmia (ComVA) in mitral valve prolapse (MVP). Methods: A retrospective analysis was performed on 41 consecutive patients with MVP referred for CMR between 2006 and 2011, and 31 healthy controls. Arrhythmia analysis was available in 23 patients with MVP with Holter/event monitors. Left ventricular (LV) septal T1 times were derived from Look-Locker sequences after administration of 0.2 mmol/kg gadopentetate dimeglumine. Late gadolinium enhancement (LGE) CMR images were available for all subjects. Results: Patients with MVP had significantly shorter postcontrast T1 times when compared with controls (334±52 vs 363±58 ms; p=0.03) despite similar LV ejection fraction (LVEF) (63±7 vs 60±6%, p=0.10). In a multivariable analysis, LV end-diastolic volume, LVEF and mitral regurgitation fraction were all correlates of T1 times, with LVEF and LV end-diastolic volume being the strongest (p=0.005, p=0.008 and p=0.045, respectively; model adjusted R2=0.30). Patients with MVP with ComVA had significantly shorter postcontrast T1 times when compared with patients with MVP without ComVA (324 (296, 348) vs 354 (327, 376) ms; p=0.03) and only 5/14 (36%) had evidence of papillary muscle LGE. Conclusions: MVP may be associated with diffuse LV myocardial fibrosis as suggested by reduced postcontrast T1 times. Diffuse interstitial derangement is linked to subclinical systolic dysfunction, and may contribute to ComVA in MVP-related mitral regurgitation, even in the absence of focal fibrosis.
1 June 2016 in Circulation: Arrhythmia and Electrophysiology
Background—: Mapping resolution is influenced by electrode size and interelectrode spacing. The aims of this study were to establish normal electrogram criteria for 1-mm multielectrode-mapping catheters (Pentaray) in the ventricle and to compare its mapping resolution within scar to standard 3.5-mm catheters (Smart-Touch Thermocool). Methods and Results—: Three healthy swine and 11 swine with healed myocardial infarction underwent sequential mapping of the left ventricle with both catheters. Bipolar voltage amplitude in healthy tissue was similar between 3.5- and 1-mm multielectrode catheters with a 5th percentile of 1.61 and 1.48 mV, respectively. In swine with healed infarction, the total area of low bipolar voltage amplitude (defined as <1.5 mV) was 22.5% smaller using 1-mm multielectrode catheters (21.7 versus 28.0 cm2; P =0.003). This was more evident in the area of dense scar (bipolar amplitude <0.5 mV) with a 47% smaller very low–voltage area identified using 1-mm electrode catheters (7.1 versus 15.2 cm 2 ; P =0.003). In this region, 1-mm multielectrode catheters recorded higher voltage amplitude (0.72±0.81 mV versus 0.30±0.12 mV; P <0.001). Importantly, 27% of these dense scar electrograms showed distinct triphasic electrograms when mapped using a 1-mm multielectrode catheter compared with fractionated multicomponent electrogram recorded with the 3.5-mm electrode catheter. In 8 mapped reentrant ventricular tachycardias, the circuits included regions of preserved myocardial tissue channels identified with 1-mm multielectrode catheters but not 3.5-mm electrode catheters. Pacing threshold within the area of low voltage was lower with 1-mm electrode catheters (0.9±1.3 mV versus 3.8±3.7 mV; P =0.001). Conclusions—: Mapping with small closely spaced electrode catheters can improve mapping resolution within areas of low voltage.
The use of proton resonance frequency shift–based magnetic resonance (MR) thermometry for interventional guidance on abdominal organs is hampered by the constant displacement of the target due to the respiratory cycle and the associated thermometry artifacts. Ideally, a suitable MR thermometry method should for this role achieve a subsecond temporal resolution while maintaining a precision comparable to those achieved on static organs while not introducing significant processing latencies. Here, a computationally effective processing pipeline for two-dimensional image registration coupled with a multibaseline phase correction is proposed in conjunction with high-frame-rate MRI as a possible solution. The proposed MR thermometry method was evaluated for 5 min at a frame rate of 10 images/sec in the liver and the kidney of 11 healthy volunteers and achieved a precision of less than 2°C in 70% of the pixels while delivering temperature and thermal dose maps on the fly. The ability to perform MR thermometry and dosimetry in vivo during a real intervention was demonstrated on a porcine kidney during a high-intensity focused ultrasound heating experiment. Magn Reson Med 63:1080–1087, 2010.
Magnetic resonance imaging‐guided high intensity focused ultrasound is a promising method for the noninvasive ablation of pathological tissue in abdominal organs such as liver and kidney. Due to the high perfusion rates of these organs, sustained sonications are required to achieve a sufficiently high temperature elevation to induce necrosis. However, the constant displacement of the target due to the respiratory cycle render continuous ablations challenging, since dynamic repositioning of the focal point is required. This study demonstrates subsecond 3D high intensity focused ultrasound‐beam steering under magnetic resonance‐guidance for the real‐time compensation of respiratory motion. The target is observed in 3D space by coupling rapid 2D magnetic resonance‐imaging with prospective slice tracking based on pencil‐beam navigator echoes. The magnetic resonance‐data is processed in real‐time by a computationally efficient reconstruction pipeline, which provides the position, the temperature and the thermal dose on‐the‐fly, and which feeds corrections into the high intensity focused ultrasound‐ablator. The effect of the residual update latency is reduced by using a 3D Kalman‐predictor for trajectory anticipation. The suggested method is characterized with phantom experiments and verified in vivo on porcine kidney. The results show that for update frequencies of more than 10 Hz and latencies of less then 114 msec, temperature elevations can be achieved, which are comparable to static experiments. Magn Reson Med, 2010.