Thermal facial imaging enables non-contact measurements of face heat patterns that are valuable for healthcare and affective computing, but common occluders (glasses, masks, scarves) and the single-channel, texture-poor nature of thermal frames make robust landmark localisation and visibility estimation challenging. We propose M3MSTL, a multi-modal, multi-stage, multi-task framework for occlusion-aware landmarking on thermal faces. M3MSTL pairs a ResNet-50 backbone with two lightweight heads: a compact fully connected landmark regressor and a Vision Transformer occlusion classifier that explicitly fuses per-landmark temperature cues. A three-stage curriculum (mask-based backbone pretraining, head specialisation with a frozen trunk, and final joint fine-tuning) stabilises optimisation and improves generalisation from limited thermal data. On the TFD68 dataset, M3MSTL substantially improves both visibility and localisation: the occlusion accuracy reaches 91.8% (baseline 89.7%), the mean NME reaches 0.246 (baseline 0.382), the ROC–AUC reaches 0.974, and the AP is 0.966. Paired statistical tests confirm that these gains are significant. Our approach aims to improve the reliability of temperature-based biometric and clinical measurements in the presence of realistic occluders.
Missing data are ubiquitous in real-world datasets and can substantially degrade the performance of statistical analyses and deep learning models when essential features are absent. Imputation methods address this problem by replacing missing entries with plausible values that preserve the underlying data structure. In this work, we evaluate CMILK (Correlation-based Multiple Imputation with Local k-neighbour matching) for imputing missing thermal facial landmark temperatures and present a Genetic Algorithm (GA)–based procedure to optimise its hyperparameters. Comparative studies verified the effectiveness of GA, while ablation studies further validate the effectiveness of the GA-driven optimisation and its impact on convergence behaviour. GA-optimised CMILK achieves consistent improvements over the baseline: mean absolute error (MAE) decreases from 0.5724 to 0.5479 (a 4.3% relative reduction) and root mean square error (RMSE) from 0.7657 to 0.7371 (a 3.7% relative reduction). Hypothesis testing confirms that the observed reduction in RMSE after GA optimisation is statistically significant, supported by consistent parametric and nonparametric analyses with a large effect size and positive confidence interval. The optimisation also widens CMILK’s lead over the next-best method to 5.0% in MAE and 7.0% in RMSE, while producing a modest runtime improvement of 12.1% versus the baseline. These results show that automated hyperparameter search using GA produces measurable gains in accuracy and efficiency, improving CMILK’s reliability for predictive modelling and robust analysis of thermal facial-landmark temperature data.
Non-contact body-temperature prediction from facial thermography is affected by pose, occlusion, missing measurements, and inter-subject variation. This study proposes a graph–tabular latent-representation fusion framework for predicting body temperature from thermal facial landmark profiles. A Pearson correlation coefficient (PCC)-guided landmark graph models landmark-to-landmark thermal dependencies. At the same time, the same landmark-temperature signal is retained as a tabular representation to preserve global temperature-pattern interactions. The graph and tabular branches are encoded independently, fused at the latent level, and trained for target-landmark temperature regression with auxiliary reconstruction losses. Experiments were conducted on TFD68 under complete, missing completely at random (MCAR), and structured missing not at random (MNAR) conditions. The structured MNAR simulation combines 3D head-pose visibility modelling, accessory-driven occlusion, validation against real TFD68 occlusion annotations, and graph-construction sensitivity analyses. Results show that selected fused configurations improve over strong stand-alone graph and tabular baselines, particularly under MNAR-imputed evaluation, with the best selected configuration reducing prediction error by approximately . Statistical testing further confirms significant improvements in most MNAR fused–baseline comparisons. Accuracy–efficiency analysis shows that fusion improves robustness at the cost of additional inference time, providing a flexible design space for thermal landmark-based body-temperature prediction.