This paper describes in detail a compact (2U format) telescope operating in the extreme ultraviolet range for studying the solar corona at a wavelength of 17.14 nm. The telescope objective has been built according to the Ritchey–Chrétien scheme with the following parameters: effective focal length of 381.3 mm, field of view of 2×2∘, and angular resolution of 11 in. Reflective multilayer Al/Be coatings were used, having 55% reflectance and a 0.4 nm spectral bandwidth. The wavefront rms error is 30 nm. An interferometric technique for controlling the shapes of the substrates and for adjusting the optical system and detector of the telescope assembly is described in detail.
The article is devoted to the development of an EUV microscope using a wavelength of 13.84 nm. Due to the use of a mirror lens with a large numerical aperture, NA = 0.27, and a short depth of focus, it has been possible to carry out z-tomography of bio-samples for the first time with this type of microscope. A 3D image was reconstructed, and a pixel resolution of 140 nm was obtained. A new simple algorithm for the 3D reconstruction of absorption images from z-tomography data has been proposed that takes into account lens aberrations and a point spread function. The algorithm reduces the inverse absorption task to the corresponding well-studied task of fluorescence microscopy, with an error of 10% for cells up to 10 µm thick.
Methods for calculating the process of axisymmetric surface shape correction with a wide-aperture ion beam through a forming diaphragm for optical elements with a round and arbitrary border shape are presented. In the case of circular optical elements, an approach based on the separation of the axisymmetric component of the surface shape error from its decomposition by Zernike polynomials is used. In the case of optical elements with an arbitrary border shape (not round), an algorithm for searching the axisymmetric component of the shape error is proposed. The search criterion is to minimize the residual volume of the deviation of the surface shape from the calculated one. The proposed algorithm makes it possible to separate the axisymmetric component of the shape error relative to an arbitrary axis, including one located outside the workpiece. The results of surface treatment in accordance with the above methods are presented.
The recent advances achieved in microscopy technology have led to a significant breakthrough in biological research. Super-resolution fluorescent microscopy now allows us to visualize subcellular structures down to the pin-pointing of the single molecules in them, while modern electron microscopy has opened new possibilities in the study of protein complexes in their native, intracellular environment at near-atomic resolution. Nonetheless, both fluorescent and electron microscopy have remained beset by their principal shortcomings: the reliance on labeling procedures and severe sample volume limitations, respectively. Soft X-ray microscopy is a candidate method that can compensate for the shortcomings of both technologies by making possible observation of the entirety of the cellular interior without chemical fixation and labeling with an isotropic resolution of 40–70 nm. This will thus bridge the resolution gap between light and electron microscopy (although this gap is being narrowed, it still exists) and resolve the issue of compatibility with the former, and possibly in the near future, the latter methods. This review aims to assess the current state of soft X-ray microscopy and its impact on our understanding of the subcellular organization. It also attempts to look into the future of X-ray microscopy, particularly as relates to its seamless integration into the cell biology toolkit.
The paper considers the possibility of using the diamond-silicon carbide composite Skeleton® with a technological coating of polycrystalline silicon as a substrate for X-ray mirrors used with powerful synchrotron radiation sources (third+ and fourth generation). Samples were studied after polishing to provide the following surface parameters: root-mean-square flatness ≃ 50 nm, micro-roughness on the frame 2 µm × 2 µm σ ≃ 0.15 nm. The heat capacity, thermal conductivity and coefficient of linear thermal expansion were investigated. For comparison, a monocrystalline silicon sample was studied under the same conditions using the same methods. The value of the coefficient of linear thermal expansion turned out to be higher than that of monocrystalline silicon and amounted to 4.3 × 10−6 K−1, and the values of thermal conductivity (5.0 W cm−1 K−1) and heat capacity (1.2 J K−1 g−1) also exceeded the values for Si. Thermally induced deformations of both Skeleton® and monocrystalline silicon samples under irradiation with a CO2 laser beam have also been experimentally studied. Taking into account the obtained thermophysical constants, the calculation of thermally induced deformation under irradiation with hard (20 keV) X-rays showed almost three times less deformation of the Skeleton® sample than of the monocrystalline silicon sample.
The paper demonstrates the possibility of forming flat substrates for grazing incidence X-ray mirrors with an accuracy of RMS ∼0.7nm, and also implements a technique for manufacturing grazing incidence X-ray optical elements with cylindrical surface profiles, using ion beam etching. The technique assumes the linear movement of the workpiece behind a slit diaphragm with a speed that varies depending on the coordinate. The result of the work was the creation of a pair of X-ray mirror substrates for a Kirkpatrick-Baez collimating system, having surface shape deviations from the ideal plane of HM1=1.05µm and HM2=1.13µm, and from the calculated parabolic cylinders of RMSM1=3.0nm and RMSM2=2.9nm. The described technique makes it possible to produce substrates for mirrors in the form of elliptical and parabolic cylinders used in commercial diffractometers, synchrotrons, and free electron lasers for collimation and focusing of X-ray radiation, as well as in the telescopes of space observatories.