Mikhail N. Toropov

Mikhail N. Toropov

Auto-generated profile, based on publicly available information

Mikhail N. Toropov

Институт физики микроструктур Российской академии наук, Нижний Новгород, Россия

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2022 in Optics Express
Verified
Journal Article
Closed access
IMIlya Malyshev
Ilya Malyshev
DRDmitry Reunov
Dmitry Reunov
NCNikolay Chkhalo
Nikolay Chkhalo
MTMichael Toropov
Michael Toropov
APAleksey E. Pestov
Aleksey E. Pestov
OSOlesya Shirokova
Olesya Shirokova
The article is devoted to the development of an EUV microscope using a wavelength of 13.84 nm. Due to the use of a mirror lens with a large numerical aperture, NA = 0.27, and a short depth of focus, it has been possible to carry out z-tomography of bio-samples for the first time with this type of microscope. A 3D image was reconstructed, and a pixel resolution of 140 nm was obtained. A new simple algorithm for the 3D reconstruction of absorption images from z-tomography data has been proposed that takes into account lens aberrations and a point spread function. The algorithm reduces the inverse absorption task to the corresponding well-studied task of fluorescence microscopy, with an error of 10% for cells up to 10 µm thick.

15 November 2022 in Applied Optics
Verified
Journal Article
Closed access
ACAleksei Chernyshev
Aleksei Chernyshev
NCNikolay Chkhalo
Nikolay Chkhalo
IMIlya Malyshev
Ilya Malyshev
MMMikhail Mikhailenko
Mikhail Mikhailenko
APAleksey E. Pestov
Aleksey E. Pestov
MTMikhail Toropov
Mikhail Toropov
Methods for calculating the process of axisymmetric surface shape correction with a wide-aperture ion beam through a forming diaphragm for optical elements with a round and arbitrary border shape are presented. In the case of circular optical elements, an approach based on the separation of the axisymmetric component of the surface shape error from its decomposition by Zernike polynomials is used. In the case of optical elements with an arbitrary border shape (not round), an algorithm for searching the axisymmetric component of the shape error is proposed. The search criterion is to minimize the residual volume of the deviation of the surface shape from the calculated one. The proposed algorithm makes it possible to separate the axisymmetric component of the shape error relative to an arbitrary axis, including one located outside the workpiece. The results of surface treatment in accordance with the above methods are presented.

12 November 2014 in Russian Microelectronics
Verified
Journal Article
Closed access
PDF file
SBS. A. Bulgakova
S. A. Bulgakova
DGD. A. Gurova
D. A. Gurova
SZS. D. Zaitsev
S. D. Zaitsev
EKE. E. Kulikov
E. E. Kulikov
ESE. V. Skorokhodov
E. V. Skorokhodov
NSN. N. Salashchenko
N. N. Salashchenko
Resistive compositions based on ter-copolymers of isobornylacrylate with methylmethacrylate and (meth)acrylic acid, which are synthesized using the controlled radical polymerization with reversible...

8 July 2022 in Optics Letters
Verified
Journal Article
Closed access
MTMikhail Toropov
Mikhail Toropov
NCNikolay Chkhalo
Nikolay Chkhalo
IMIlya Malyshev
Ilya Malyshev
NSNikolay Salashchenko
Nikolay Salashchenko
A high-aperture low-coherence interferometer with a diffraction reference wave based on a tipped single-mode optical fiber was proposed and investigated. Due to the usage of the central least-aberrated region of the diffracted wavefront, the interferometer comprise record working aperture among known PDIs. The interferometer makes it possible to study samples with a reflectance that varies over a wide range. A demonstration of the use of this interferometer for high-precision measurements of a spherical mirror is presented. Sub-nanometer reproducibility of measurements in terms of the peak to valley (PV) parameter and sub-angstrom reproducibility in terms of the rms are demonstrated.

6 August 2024 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
APAleksey E. Pestov
Aleksey E. Pestov
ALAleksei Ya. Lopatin
Aleksei Ya. Lopatin
PVPetr Volkov
Petr Volkov
MZMaria V. Zorina
Maria V. Zorina
ALAndrei Yu. Lukyanov
Andrei Yu. Lukyanov
SKSvetlana B. Korchagina
Svetlana B. Korchagina
The paper considers the possibility of using the diamond-silicon carbide composite Skeleton® with a technological coating of polycrystalline silicon as a substrate for X-ray mirrors used with powerful synchrotron radiation sources (third+ and fourth generation). Samples were studied after polishing to provide the following surface parameters: root-mean-square flatness ≃ 50 nm, micro-roughness on the frame 2 µm × 2 µm σ ≃ 0.15 nm. The heat capacity, thermal conductivity and coefficient of linear thermal expansion were investigated. For comparison, a monocrystalline silicon sample was studied under the same conditions using the same methods. The value of the coefficient of linear thermal expansion turned out to be higher than that of monocrystalline silicon and amounted to 4.3 × 10−6 K−1, and the values of thermal conductivity (5.0 W cm−1 K−1) and heat capacity (1.2 J K−1 g−1) also exceeded the values for Si. Thermally induced deformations of both Skeleton® and monocrystalline silicon samples under irradiation with a CO2 laser beam have also been experimentally studied. Taking into account the obtained thermophysical constants, the calculation of thermally induced deformation under irradiation with hard (20 keV) X-rays showed almost three times less deformation of the Skeleton® sample than of the monocrystalline silicon sample.

16 June 2023 in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
Verified
Journal Article
Closed access
PDF file
IMIlya Malyshev
Ilya Malyshev
APAleksey E. Pestov
Aleksey E. Pestov
VPVladimir Polkovnikov
Vladimir Polkovnikov
DRD. G. Reunov
D. G. Reunov
MTM. N. Toropov
M. N. Toropov
ISI. A. Shchelokov
I. A. Shchelokov
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.