Rosca Rosca

Dr. Rosca Rosca


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2018 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
MMM. Munteanu
M. Munteanu
RRRosca Rosca
Rosca Rosca
HSH. Stanca
H. Stanca

30 May 2024 in Healthcare
Verified
Journal Article
Open access
PDF file
CPCristina Patricia Pac
Cristina Patricia Pac
José-María Sánchez-GonzálezJosé-María Sánchez-González
José-María Sánchez-González
Carlos Rocha-de-LossadaCarlos Rocha-de-Lossada
Carlos Rocha-de-Lossada
NMNadina Mercea
Nadina Mercea
FFFrancis Ferrari
Francis Ferrari
Mihnea MunteanuMihnea Munteanu
Mihnea Munteanu
Background: Dry eye disease (DED), a prevalent condition with a multifactorial etiology, significantly impacts global health by causing discomfort and visual disturbance. This historical cohort study evaluates the efficacy of Intense Pulsed Light (IPL) therapy on meibomian gland dysfunction (MGD)-related evaporative DED. Methods: The study involved 110 patients (220 eyes) who underwent IPL therapy. Ethical approval was secured, and informed consent was obtained from all participants. A Tearcheck® (ESWvision, Houdan, France) device was used for ocular surface evaluation, measuring tear film stability (NIFBUT, NIABUT), tear film quantity (CTMH, TTMH), and inflammation (OSIE). The study assessed tear film and ocular surface health across multiple IPL sessions. Results: Significant improvements were observed in subjective symptoms (EFT score increased from 29.10 ± 8.87 to 35.91 ± 7.03, p < 0.01), tear film stability (NIFBUT increased from 9.37 ± 6.04 to 10.78 ± 5.83 s, p < 0.01; NIABUT increased from 11.07 ± 4.98 to 12.34 ± 4.66 s, p < 0.01), and tear film surface evaluation (TFSE score decreased from 337.78 ± 414.08 to 206.02 ± 240.44, p < 0.01). Tear film quantity remained unchanged (CTMH and TTMH, p > 0.05). Conclusions: IPL therapy is a promising treatment for DED, improving symptoms and ocular surface health. Further research is warranted to explore long-term efficacy and optimization.

27 April 2013
Verified
Journal Article
Closed access
Mihnea MunteanuMihnea Munteanu
Mihnea Munteanu
SGS Giuri
S Giuri
RRRosca Rosca
Rosca Rosca
OBO Boruga
O Boruga
OCO Creţu
O Creţu

27 March 2026 in Journal of Gastrointestinal and Liver Diseases
Verified
Journal Article
Open access
RRRosca Rosca
Rosca Rosca
ARAnca Maria Rednik-Pusca
Anca Maria Rednik-Pusca

22 June 2026 in Women
Verified
Journal Article
Open access
PDF file
DIDumitriu Bogdan Ionel
Dumitriu Bogdan Ionel
DIDumitriu Alina Iasmina
Dumitriu Alina Iasmina
FSFlavius George Socol
Flavius George Socol
ISIoana Denisa Socol
Ioana Denisa Socol
EIEnatescu Ileana
Enatescu Ileana
AGAdrian Gluhovschi
Adrian Gluhovschi
When women choose a contraceptive method, the decision depends not only on what they prefer but also on the quality of the information they encounter online and on how confident they feel about using a method. We examined how exposure to inaccurate online contraceptive information (“digital misinformation”) and uncertainty about contraceptive decisions (“decisional conflict”) related to mental health and quality of life in women with and without a history of abortion. This was a cross-sectional study of 134 women aged 18–42 years attending obstetrics–gynecology or family-planning services at one Romanian tertiary center. Women were grouped as having no prior abortion (n = 41), one prior abortion (n = 53), or repeat abortion (n = 40). We measured a study-specific digital misinformation index, an access barrier index, contraceptive self-efficacy, reproductive autonomy, depression (PHQ-9), anxiety (GAD-7), well-being (WHO-5), quality of life (WHOQOL-BREF), and current use of highly effective contraception. We compared groups and used regression, mediation, and exploratory profiling. Women with repeat abortion reported the most online misinformation (10.0 ± 2.0), the most decisional conflict (43.9 ± 9.3), the lowest quality of life (61.3 ± 5.6), and the lowest use of highly effective contraception (45.0%). More misinformation and more access barriers were each associated with greater decisional conflict, while higher self-efficacy was associated with less. In this cross-sectional sample, online misinformation and decisional uncertainty were associated with reproductive vulnerability more closely than abortion count alone. Findings are associational and require prospective confirmation.

25 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Leila Al BarriLeila Al Barri
Leila Al Barri
IYIonela Iasmina Yasar
Ionela Iasmina Yasar
NMNadina Mercea
Nadina Mercea
ATAnca Tudor
Anca Tudor
Horia Tudor StancaHoria Tudor Stanca
Horia Tudor Stanca
Mihnea MunteanuMihnea Munteanu
Mihnea Munteanu
Background and Objectives: Accurate anterior segment measurements are central to intraocular lens (IOL) power calculation and toric planning, yet different optical platforms may yield non-interchangeable values. This study compared keratometry, astigmatism metrics, and ocular biometry obtained with a swept-source OCT biometer (Argos), an optical low-coherence interferometry biometer (Aladdin), and a combined Scheimpflug–Placido topographer (Schwind Sirius). Methods: Retrospective observational study (January 2022–June 2024) including eyes undergoing uncomplicated cataract surgery. All eyes were measured in a single session by one examiner. Outcomes included K1, K2, cylinder, astigmatism axis (“Powerful Angle”), vector components (J0, J45), and—where available—lens thickness (LT), axial length (AL), anterior chamber depth (ACD), white-to-white (WTW), and central corneal thickness (CCT). Friedman tests assessed 3-device differences; Mann–Whitney U tests evaluated pairwise comparisons. Results: A total of 170 eyes (102 patients) were analyzed (mean age 69.12 ± 10.26 years). Significant interdevice differences were detected for K1 (Argos 43.45 ± 1.64 D, Aladdin 43.41 ± 1.70 D; overall p < 0.001; Argos vs Aladdin p = 0.019), K2 (Argos 44.45 ± 1.67 D, Aladdin 44.34 ± 1.71 D; overall and pairwise p < 0.001), and cylinder (Argos −0.83 ± 0.74 D, Aladdin −0.77 ± 0.76 D, Sirius −0.68 ± 0.75 D; overall p < 0.001). “Powerful Angle” differed across devices (p = 0.003) but not between Argos and Aladdin (p = 0.512). J0 (p = 0.277) and J45 (p = 0.084) did not differ significantly. Argos reported higher ACD (3.19 ± 0.42 vs 3.13 ± 0.41 mm, p < 0.001) and WTW (11.95 ± 0.42 vs 11.65 ± 0.39 mm, p < 0.001) than Aladdin. CCT was similar between Aladdin and Sirius (540.27 ± 33.44 vs 540.47 ± 33.78 µm, p = 0.169). Conclusions: Several keratometric and biometric parameters differed significantly by device, indicating limited interchangeability—particularly relevant for toric and pre-mium IOL planning—while vector astigmatism components and CCT showed better agreement.