Qiumei Jiang

Dr. Qiumei Jiang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
WXWeiqiao Xu
Weiqiao Xu
ZMZhenting Ma
Zhenting Ma
QTQixin Tian
Qixin Tian
YCYuanqing Chen
Yuanqing Chen
QJQiumei Jiang
Qiumei Jiang
LFLiang Fan
Liang Fan
PH is a critical parameter requiring precise monitoring across scientific, industrial, and biological domains. Fluorescent pH probes offer a powerful alternative to traditional methods (e.g., electrodes, indicators), overcoming limitations in miniaturization, long-term stability, and electromagnetic interference. By utilizing photophysical mechanisms—including intramolecular charge transfer (ICT), photoinduced electron transfer (PET), and fluorescence resonance energy transfer (FRET)—these probes enable high-sensitivity, reusable, and biocompatible sensing. This review systematically details recent advances, categorizing probes by operational pH range: strongly acidic (0–3), weakly acidic (3–7), strongly alkaline (>12), weakly alkaline (7–11), near-neutral (6–8), and wide-dynamic range. Innovations such as ratiometric detection, organelle-specific targeting (lysosomes, mitochondria), smartphone colorimetry, and dual-analyte response (e.g., pH + Al3+/CN−) are highlighted. Applications span real-time cellular imaging (HeLa cells, zebrafish, mice), food quality assessment, environmental monitoring, and industrial diagnostics (e.g., concrete pH). Persistent challenges include extreme-pH sensing (notably alkalinity), photobleaching, dye leakage, and environmental resilience. Future research should prioritize broadening functional pH ranges, enhancing probe stability, and developing wide-range sensing strategies to advance deployment in commercial and industrial online monitoring platforms.

21 January 2026 in Metals
Verified
Journal Article
Open access
PDF file
XLXiufen Liao
Xiufen Liao
LFLiang Fan
Liang Fan
QJQiumei Jiang
Qiumei Jiang
MZMaomi Zhao
Maomi Zhao
SHSong qiang Huang
Song qiang Huang
BHBaorong Hou
Baorong Hou
Conventional anticorrosive coatings suffer from limitations of low solid content and rigorous surface pretreatment, posing environmental and cost challenges in field applications. In this study, a novel high-solid-content (>95%) epoxy-polysiloxane (Ep-PSA) ceramic metal coating was prepared that enables low-surface-treatment application. The originality lies in the synergistic combination of nano-sized ceramic powders, high-strength metallic powders, polysiloxane resin (PSA), and solvent-free epoxy resin (Ep), which polymerize through an organic–inorganic interpenetrating network to form a dense shielding layer. The as-prepared Ep-PSA coating system chemically bonds with indigenous metal substrate via Zn3(PO4)2 and resin functionalities during curing, forming a conversion layer that reduces surface preparation requirements. Differentiating from existing high-solid coatings, this approach achieves superior long-term barrier properties, evidenced by |Z|0.01Hz value of 9.64 × 108 Ω·cm2, after 6000 h salt spray exposure—four orders of magnitude higher than commercial 60% epoxy zinc-rich coatings (2.26 × 104 Ω·cm2, 3000 h salt spray exposure). The coating exhibits excellent adhesion (14.28 MPa) to standard sandblasted steel plates. This environmentally friendly, durable, and easily applicable composite coating demonstrates significant field application value for large-scale energy infrastructure.

15 May 2025 in Coatings
Verified
Journal Article
Open access
PDF file
SXSongbo Xie
Songbo Xie
XLXiufen Liao
Xiufen Liao
YFYanye Fan
Yanye Fan
JLJiacheng Li
Jiacheng Li
QJQiumei Jiang
Qiumei Jiang
SLShella Li
Shella Li
Traditional marine antifouling coatings function through releasing toxic antifouling agents, causing serious harm to marine ecosystems. To address this challenge, an eco-friendly fluoro-silicon-modified polythiourethane (FSi-PTU) coating has been prepared via a polymerization reaction with dihydroxy propyl silicone oil (HO-PDMS-OH), 1H,1H,2H,2H-perfluorohexanol (FTOH), hexamethylene diisocyanate (HDI), and pentaerythritol tetrakis (3-mercaptopropionate) (PETMP). The FSi-PTU polymer incorporates siloxane segments and fluorinated side chains, which are inhomogeneously distributed on the coating surface and construct a hydrophobic surface. The FSi-PTU coating exhibits good hydrophobicity, strong adhesion (≥2.14 MPa), and improved mechanical properties. The antifouling properties of the FSi-PTU coating have been researched. The results of laboratory tests demonstrate that the FSi-PTU coating exhibits excellent anti-protein adsorption and anti-algal attachment performance. The FSi-PTU-2 coating shows certain antifouling properties in the actual seawater test for three months. The results provide a certain reference value for developing eco-friendly marine antifouling coatings.

9 June 2026 in Materials
Verified
Journal Article
Open access
PDF file
XLXiufen Liao
Xiufen Liao
ZGZhilin Gong
Zhilin Gong
CSCongtao Sun
Congtao Sun
JLJun-Xiang Lai
Jun-Xiang Lai
QJQiumei Jiang
Qiumei Jiang
JXJing Xiang
Jing Xiang
Developing an environmentally friendly material with dual functionality of corrosion monitoring and inhibition is crucial for reducing economic losses. Herein, dual-function phytic acid carbon dots (PA-CDs) were prepared with a hydrothermal treatment method for corrosion monitoring and inhibition. The as-prepared PA-CDs exhibited a distinct color change from brown-yellow to wine-red immediately in the presence of OH−, and H+ can restore the color of the PA-CDs-OH− system from wine-red to brown-yellow. Inspired by the above phenomenon, a visible RGB-based colorimetric sensor was fabricated by combining PA-CDs coatings with the self-made RGB-sensing device to detect OH−/H+ during metal corrosion. In addition, PA-CDs had excellent corrosion inhibitory properties for Q235 steel hanging sheets in hydrochloric acid solutions, and the corrosion inhibition efficiency reached 96.40%. The excellent corrosion monitoring and inhibition properties demonstrate the potential application of the PA-CDs in engineering practice.