Dmitriy G. Reunov

Dmitriy G. Reunov

Auto-generated profile, based on publicly available information

Dmitriy G. Reunov


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2023 in Acta Naturae
Verified
Journal Article
Open access
PDF file
SGSergei Golyshev
Sergei Golyshev
EKE. P. Kazakov
E. P. Kazakov
IKIgor Kireev
Igor Kireev
DRD. G. Reunov
D. G. Reunov
IMIlya Malyshev
Ilya Malyshev
The recent advances achieved in microscopy technology have led to a significant breakthrough in biological research. Super-resolution fluorescent microscopy now allows us to visualize subcellular structures down to the pin-pointing of the single molecules in them, while modern electron microscopy has opened new possibilities in the study of protein complexes in their native, intracellular environment at near-atomic resolution. Nonetheless, both fluorescent and electron microscopy have remained beset by their principal shortcomings: the reliance on labeling procedures and severe sample volume limitations, respectively. Soft X-ray microscopy is a candidate method that can compensate for the shortcomings of both technologies by making possible observation of the entirety of the cellular interior without chemical fixation and labeling with an isotropic resolution of 40–70 nm. This will thus bridge the resolution gap between light and electron microscopy (although this gap is being narrowed, it still exists) and resolve the issue of compatibility with the former, and possibly in the near future, the latter methods. This review aims to assess the current state of soft X-ray microscopy and its impact on our understanding of the subcellular organization. It also attempts to look into the future of X-ray microscopy, particularly as relates to its seamless integration into the cell biology toolkit.

14 October 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
APA A Perekalov
A A Perekalov
NCN I Chkhalo
N I Chkhalo
VGV E Guseva
V E Guseva
IMI V Malyshev
I V Malyshev
ANA N Nechay
A N Nechay
NTN N Tsybin
N N Tsybin
In this article, we report on the development, construction and operation of a microscope to study the emission radiation of laser plasma in the EUV spectral range. The main optical unit of the microscope is a two-mirror spherical Schwarzschild objective with a 5x magnification. The microscope builds an image of the plasma cloud at a wavelength of 11.25 nm. This wavelength is determined by the manufactured multilayer x-ray mirrors based on a Mo/Be structure. To suppress the long-wave noise component of the signal in the VUV, UV, visible and IR spectral range, we used two thin-film Mo/Be filters. The device was calibrated on the basis of both EUV radiation registration efficiency and spatial resolution at the operating wavelength, these being 12% and 3.9 μm, respectively. We also discuss the results of studying the size of a laser spark in gas-jet targets.

16 June 2023 in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
Verified
Journal Article
Closed access
PDF file
IMIlya Malyshev
Ilya Malyshev
APAleksey E. Pestov
Aleksey E. Pestov
VPVladimir Polkovnikov
Vladimir Polkovnikov
DRD. G. Reunov
D. G. Reunov
MTM. N. Toropov
M. N. Toropov
ISI. A. Shchelokov
I. A. Shchelokov
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.

1 December 2024 in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
Verified
Journal Article
Closed access
PDF file
DRD. G. Reunov
D. G. Reunov
AAA. D. Akhsakhalyan
A. D. Akhsakhalyan
EGE. I. Glushkov
E. I. Glushkov
IZI. G. Zabrodin
I. G. Zabrodin
IMI. V. Malyshev
I. V. Malyshev
NCN. I. Chkhalo
N. I. Chkhalo
The article describes an X-ray optical certification setup based on a microfocus X-ray tube, a Kirkpatrick-Baez (KB) collimating system, and a Gpixel2020BSI matrix semiconductor detector. To minimize X-ray beam scattering and intensity loss due to absorption in air, vacuum-tight tubes with compton windows are installed between the microfocus X-ray tube and the KB system, and between the KB system and the detector. Pumping is performed by an oil-free fore-vacuum pump. The setup that has been developed allows for studying the X-ray optical scheme of two-mirror monochromators to determine the deformation of the beam wave front at their outputs, and to calibrate the movement of high-precision mechanical tables. The setup also allows for studying the focusing properties of the Kirkpatrick-Baez system, itself, namely, measuring the size of the focus spot and calibrating the piezo-drives of the mirrors. As a result of adjusting the collimating system, we obtained a converging beam, but this did not prevent us from measuring the wave front broadening upon reflection from the substrates for a two-mirror monochromator. Two substrates made of single-crystal silicon Si(100) were studied. It was shown that upon reflection from the substrate after chemical-mechanical polishing (CMP) only, the reflected beam, due to mirror shape errors, broadened by 18 μm, while after chemical-mechanical polishing and correction of local shape errors using an ion beam, the broadening was reduced to 11 μm, which corresponds to an angular error of the mirror at a level of 3 μrad. This is 7 times less than the angular divergence of the beam at the output of the collimating system, due to the size of the radiation source.

7 June 2024 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
DRDmitriy G. Reunov
Dmitriy G. Reunov
AAAnton A. Akhsakhalyan
Anton A. Akhsakhalyan
AAAram D. Akhsakhalyan
Aram D. Akhsakhalyan
NСNicholay Ivanovich Сhkhalo
Nicholay Ivanovich Сhkhalo
RSRoman A. Shaposhnikov
Roman A. Shaposhnikov
YDYuri N. Drozdov
Yuri N. Drozdov

1 August 2023 in Poverhnostʹ. Rentgenovskie, sinhrotronnye i nejtronnye issledovaniâ
Verified
Journal Article
Closed access
PDF file
DRD. G. Reunov
D. G. Reunov
IMI. V. Malyshev
I. V. Malyshev
APA. A. Perekalov
A. A. Perekalov
ANA. N. Nechay
A. N. Nechay
NCN. I. Chkhalo
N. I. Chkhalo
The size and intensity of laser-plasma sources based on pulsed argon gas jets operating at a wavelength of 13.84 nm were studied. The gas jet was excited by laser radiation at a wavelength of 1064 nm with a pulse duration of 4.4 ns, a repetition frequency of 10 Hz, and a pulse energy of 0.5 J. Two methods of forming a jet of a pulsed gas target were studied: using a jet with a supersonic nozzle and using a capillary. The capillary source is commercially available. The sources were certified using a mirror microscope operating in the extreme ultraviolet region at a wavelength of 13.84 nm. It was found that due to the possibility of supplying a higher pressure of the working gas to the nozzle inlet, increasing the density and reducing the exit angle of the gas jet in the supersonic nozzle compared to the capillary, the peak radiation intensity at a wavelength of 13.84 nm increased six times. The full width at half maximum of the nozzle-based source diameter was 250 ± 10 μm with a profile close to Gaussian. In the field of view of a microscope of 25 × 25 μm, the nonuniformity of illumination from the “source on the nozzle” is about 1%; in the field of view of 50 × 50 μm, it is about 4%. The full width at half maximum of the source diameter based on a commercial valve with a capillary source was 330 ± 10 µm with a profile close to П-shaped. Based on the results of the comparison, an upgraded version of the microscope with up to 350× magnification will use a nozzle-based source.